6. ELECTRICAL DATA

6-1. Electrical Characteristics
Indoor Unit
MCAV180R5VAA
Outdoor Unit
GR180R5TAA
COOLING
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
HEATING
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Indoor Unit
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 46°C D.B.
Indoor Unit
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.
Fan Motor
Fan Motor
230V Single phase 50Hz
0.38
0.50
0.072
0.093
0.38
0.50
0.072
0.093
Fan Motor
Fan Motor
230V Single phase 50Hz
0.38
0.50
0.072
0.093
0.38
0.50
0.072
0.093
34
Outdoor Unit
Compressor
8.92
1.935
11.12
2.385
Outdoor Unit
Compressor
9.42
1.985
11.82
2.565
Complete Unit
9.8
2.10
12.0
2.55
Complete Unit
10.3
2.15
12.7
2.73