Soyal AR721HV3 Hardware Operation Manual

Soyal AR721HV3 Hardware Operation Manual

Proximity reader
Hide thumbs Also See for AR721HV3:

Advertisement

Soyal AR721HV3 hardware operation manual
Revision: V1
Date released: 1 Nov 2006
1. INTRODUCTION
Getting to know your SOYAL Proximity Reader....
The AR-721HV3 & AR-721HV1356 are smart single door controller. It built-in a 6" RF
reader and an external reader port for exit or anti-pass-back use. It can work standalone
including 1000 cardholders with anti-pass-back function. Or connect with multi-door
networking controller to provide 15,000 cardholders with multi door anti-pass-back
access control. About networking of AR-721H series. Once the network communication
stop over 10 seconds on the RS-485 port. It will auto enter standalone control mode .
Notice:
The reader of AR-721HV2 owns the same functions as AR-721HV3 except for Calendar
& Time system supporting and 1,200 Transaction Buffer features.
Copyright © 2004 Soyal Technology Co. Ltd.
All Rights Reserved.
2. Features
Calendar & Time system supporting.
Providing proximity card flash edit mode
for easy & quick setting.
Two Sets of Auto-Open Zone Function.
Built-in opened door relay, alarm relay
and request to exit button input.
Up to 1,200 Transaction Buffer.
Master Card Range assignable.
Run as a standalone controller during
Host controller failure.
Support Auto-relock Function.
Universal serial port supported for LED display, printer, Lift controller, etc.
Intergrades any brand, any frequency of Wiegand reader with soyal or other access
control systems.
Keypad will be locked for 30 seconds while continuous error operation.
Press [*] + [#] to lock / unlock keypad immediately.
Built-in watchdog to prevent the system from halting.
Door unlock time setting, latched-on/latched-off or momentary 0.1-600 seconds.
Alarm function is available (temper, force entrance, door open too long, duress).
12 numeric keypad, 1 bicolor LED (green and red) and buzzer indicator.
SOYAL
Access Control System
UM_SoyalAR721HV3V1
2

Table of Contents

1 Introduction
--------------------------------------------------------------------------- 2
2
Features
--------------------------------------------------------------------------- 2
3
Specification
-------------------------------------------------------------------------- 3
4
Installation Notice ------------------------------------------------------------------------- 4
5
Front Panel Indicators ---------------------------------------------------------------------- 7
6
------------------------------------------------------------------------- 8
AR-721HV3/1356 -------------------------------------------------------------------- 8
-------------------------------------------------------------------- 9
Force on/off Code (4 sets, 4 digits) ---------------------------------------------- 9
7 Function Default Value ---------------------------------------------------------------------- 11
---------------------------------------------------------------------- 13
----------------------------------------------------------------------- 14
--------------------------------------------------------------- -------25
--------------------------------------------------------------- ------- 25
--------------------------------------------------------- -------------25
-------------------------------------------------------- ---------------26
※ Removable CPU ------------------------------------------------------------ ---------- - 26
--------------------------------------------------------------- ---------27
15 Mode 8 Easy Guide ---------------------------------------------------------------- ---------31
16 Mode 6 Easy Guide ---------------------------------------------------------------- ---------32
17 Mode 7 Easy Guide ----------------------------------------------------------------- --------34
------------------------------------------------------------------ --------36
19 Transponder Record Table --------------------------------------------------------- ------- 39
19.2 For AR-721H6 ------------------------------------------------------------------ ------- 40
------------------------------------------------------------------------ 41
3. Specification
Mode Description:
MODE
M4
Card Holder
1024
Card Code
32 bits
Lift Control
32
Anti-Pass-back
1024
Connect to 716EV2
Y
PC
Y
Access Mode
A
Transaction Buffer
1200
Access Mode A: Card only, Card + PIN, PIN + Code
Access Mode B: Card only, PWD only, Card + PWD
Access Mode C: Card Only, Card + PIN, PIN only
How to get the Mode Status
Step 1. Press
* + 1
2
3
4
5
6 + #
enter the FUNCTION MENU
Step 2. You will hear the "Beep"sound from the
machine , as follows:
M4: Sound with 4 times
M6: Sound with 6 times
M8: Sound with 8 times
How to change the Mode Status
Step 1. Press
#
+ 1
2
3
4
5
6 + #
enter the FUNCTION MENU
Step 2. Editing Mode
M4:press
0
4
*
4
# and hearing
Beep Sound with 4 times
# and hearing
M6: press
0
4
*
6
Beep Sound with 6 times
# and hearing
M8: press
0
4
*
8
Beep Sound with 8 times
Page
---------------------------- 8
------------------------------------ 39
1
M6
M8
65536
1024
16 bits
32 bits
*
32
*
1024
*
Y
*
Y
B
C
*
1200
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR721HV3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Soyal AR721HV3

  • Page 1: Table Of Contents

    6 + # enter the FUNCTION MENU Universal serial port supported for LED display, printer, Lift controller, etc. Step 2. Editing Mode Intergrades any brand, any frequency of Wiegand reader with soyal or other access M4:press # and hearing control systems.
  • Page 2: Installation Notice

    4. Installation Notice AR-721HV3 / 1356 RS-232: The distance between PC and converter Drawing 1 (AR-801CM) can not be more than 2 meters RS-485: The distance between converter (AR-801CM) and the farthest controller (or reader) can not be more than 300 meters. Reader Lock Separate installation...
  • Page 3: Access Mode

    6. Access Mode Duress function How to program This function could help users to send a message to the computer asking for help. ---2222 Duress Code (network) Only available in networking state, running 701 Server and setting 4 sets of Duress ---1111 Force On/Off Code (network) code on PC.
  • Page 4: Wiring

    Lock( -GND ) Power Supply 12VDC 2A Lock (+ 12VDC ) Power Supply Magnettic Lock 12VDC 2A AR-721H Standalone Controller 721H 7AC2 721H 7AC2 Push Button DOOR EXIT Push Button SOYAL DOOR EXIT SOYAL Power Supply 12VDC 500mA Power Supply 12VDC 500mA...
  • Page 5 RELAY ( + 12VDC ) Blue White Lock ( -GND ) ( NO. ) Black Black - GND ) White( COM. ) AR-721U -GND SOYAL Purple(Exit Switch -GND Black Color Function + 12VDC Blue Blue DAT:1 Green Green DAT:0 Pink...
  • Page 6 721H 721H RELAY RELAY 7AC2 7AC2 7AC2 RELAY RELAY Busy DI.4 AR-716EV2 DI.3 DI.2 DI.1 PORT1 PORT2 Node: 009 SOYAL SOYAL Node: 016 Power Supply Black 15VDC 2A Black 721H 721H 7AC2 7AC2 SOYAL AR-737U 727i HOST -GND Battery Black...
  • Page 7: Installation

    (all new units are preprogrammed with the master code 123456) repair, neglect, acts of God (such as floods, fire, etc.). SOYAL shall, at its option, either 2. Flash master card and then press within 2 seconds.
  • Page 8: Mode 8 Easy Guide

    Add a User Code to the system Add one Transponder (Card / Key Tag) to the system Step1: Press and master code fallow an Step2: Enter Step1: Press and master code fallow an User Number Step2: Enter User Number User Code The user number 00001 can access the door by just either flash card or entering the Quantity user number 00001, then entering 2081#.
  • Page 9: Mode 6 Easy Guide

    16. Mode 6 Easy Guide Add the common Code to the system Step1: Press and master code fallow an Step2: Enter Enter the programming mode Common Code Press All users can access the door by only entering common code (Default value: 4321) on the unit.
  • Page 10: Special Design

    18. Special Design 18.1 How to set anti-pass-back? AR-721H do anti-pass-back with 2 pcs of AR-661U Card and on-line reader (or standalone controller) must be both set anti-pass-back. Set card to have anti-pass back checking Step1: Press and master code fallow an Yellow (all new units are preprogrammed with the master code 123456) White...
  • Page 11: For Ar-721H6

    Note that this function cannot use with Arming function at the same time. In edit mode, please press the buttons as below: Q : How to delete all Transponders in your SOYAL reader ? In edit mode, press then the Q : How to set Door-bell system ? data will be erased in your system.