Download Print this page
Sanyo 42TS32A Specifications
Sanyo 42TS32A Specifications

Sanyo 42TS32A Specifications

Ceiling suspended air conditioner

Advertisement

Quick Links

SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
42TS32A
TS4232/C4232A
CEILING SUSPENDED AIR CONDITIONER
GENERAL DATA
POWER V/PH/HZ
Circuit Ampacity, Min. (A)
Fuse size, Max.
(A)
COMPRESSOR
No. used
R.L. Amps - L.R. Amps (A)
Crankcase Heater
OUTDOOR FAN - TYPE
Dia. (in.) - No. used
Type Drive - No. speeds
No. Poles - RPM (High)
No. Motors - Watts
CFM (High)
F.L. Amps. (A)
OUTDOOR COIL - TYPE
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR FAN - TYPE
Dia. (in.) - No. used
No. speeds
No. Poles -RPM (High)
No. Motors - Watts
CFM (HI/MED/LOW)
F.L. Amps (A)
INDOOR COIL - TYPE
Fin Type - Pipe type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Drain Connection Size (in.)
REFRIGERANT
Lbs. - R22 (O.D. Unit)
Control
Connection
Line Length, Max
(ft.)
Lift difference, Max (ft.)
Line Size - in. O.D. Discharge
Line Size - in. O.D. Suction
DIMENSIONS (in.)
H
Indoor Unit
-Uncrated
9-7/16
-Crated
12-15/32 x 66-1/16x 31-1/16
Outdoor Unit -Uncrated
48-5/8
-Crated
52ñ7/32 x 40
WEIGHT
INDOOR
Net
(lbs.)
84
Shipping (lbs.)
97
Shipping Volume (cu.ft.)
13.6
(AT 230V)
230/208/1/60
30
50
Scroll-Hermetic
1
18.1 ñ 131
-
Propeller
18-3/32 - 2
Direct ñ 3 (AUTO)
6 - 879
2 - 110
3,450
1.8
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 - 12.7
11.63
3/8
Centrifugal
5-29/32-4
3 & Auto
4 - 1,015
1 - 100
900/790/680
0.7
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
3 - 14.9
3.51
5/16
3/4
R22
9.7
Capillary Tube
Flare
165
100
3/8
3/4
x
W x
D
x 62
x 26-3/8
x 37
x 13-3/8
x 16-3/8
OUTDOOR
205
229
19.8
AIRCONDITIONING PRODUCTS
PERFORMANCE DATA @ A
RI STANDARD CONDITIONS
COOLING
Total Capacity
(BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity
(BTU/H)
SEER
Dehumidification
(Pints/H)
Amps
(A)
Power Inputs
(W)
Outdoor Sound Rating (bels)
FEATURE
Controls
Remote Controller
Temperature Control
Timer
Night-Setback
Air Louver
(Horizontal)
(Vertical)
Power Failure Automatic Restart
Self Diagnosis
OPTION
Refrigerant Line Set
Low Ambient Control
Fresh Air Intake
Airduct Extension
Condensate Drain Pump
Non-Removable Remo-con Bracket
Wired Remote Control
OPERATING RANGE
Cooling
Indoor Air
Intake Temp.
Maximum
95 F DB/71 F WB
Minimum
67 F DB/57 F WB
CERTIFICATION
SS42TS32A-2
(230/208V)
42,000/40,500
22,500/21,530
19,500/18,970
10.2/10.3
14.8/14.6
20.6/21.0
4,190/4,100
7.9
Microprocessor
LCD Wireless type
IC Thermostat
ON/OFF, 24 hours
Built-In
Manual
Automatic
Built-In
N/A
AP3210BH
(30 ft)
AP3215BH
(50 ft)
Built-In
Built-In
N/A
N/A
RCS5PS4B
RCS-102WD/RCS-302WD
Outdoor Air
Intake Temp.
115 F DB
67 F DB
42TS32A

Advertisement

loading

Summary of Contents for Sanyo 42TS32A

  • Page 1 SUBMITTAL SHEET SYSTEM INDOOR/OUTDOOR 42TS32A TS4232/C4232A CEILING SUSPENDED AIR CONDITIONER GENERAL DATA (AT 230V) POWER V/PH/HZ 230/208/1/60 Circuit Ampacity, Min. (A) Fuse size, Max. COMPRESSOR Scroll-Hermetic No. used R.L. Amps - L.R. Amps (A) 18.1 ñ 131 Crankcase Heater OUTDOOR FAN - TYPE Propeller Dia.
  • Page 2 SUBMITTAL SHEET SYSTEM INDOOR/OUTDOOR 42TLS32A TS4232/CL4232A CEILING SUSPENDED LOW AMBIENT AIR CONDITIONER GENERAL DATA (AT 230V) POWER V/PH/HZ 230/208/1/60 Circuit Ampacity, Min. (A) Fuse size, Max. COMPRESSOR Scroll-Hermetic No. used R.L. Amps - L.R. Amps (A) 18.1 ñ 131 Crankcase Heater...

This manual is also suitable for:

C4232aTs423242tls32a