3-Position Dip Switch; Regulatory Compliance; Installation/Operation [Precautions] - Advantech EKI-1751PI-M-AE User Manual

Eki-1751pi series long reach poe extenders
Table of Contents

Advertisement

5.1

3-Position DIP Switch

Proscend EKI-1751PI Series are equipped with DIP Switch selection, which can
allow users to select the parameters in order to meet the needs of different applica-
tions. The parameter options should be set identically on EKI-1751PI Series.
Option
On
Off
5.1.1

Regulatory Compliance

EKI-1751PI Series are designed to comply with the following standards
CE
FCC Part 15 Class A
EN60950
5.1.2

Installation/Operation [Precautions]

Note!
Caution! Restricted Access Location
This server is intended for installation only in restricted access locations
as defined where both these conditions apply:
EKI-1751PI Series User Manual
Profile
Asymmetrical
Symmetrical
Disconnect all power from devices before attempting installation.
Disconnect power to the devices before any I/O and DIP configura-
tion.
DO NOT connect EKI-1751PI Series to the same power source.
Possible damages may be caused to devices due to power loop
back through the PoE connections via copper wire.
This point-to-point application is only for EKI-1751PI Series to con-
nect together.
Access is through the use of a lock or tool and key, or other means
of security, and is controlled by the authority responsible for the
location.
Access can only be gained by service persons or by users who
have been instructed about the reasons for the restrictions applied
to the location and about any precautions that shall be taken.
14
SNR
Remote Power
6dB
Enable
9dB
Disable