Fujitsu ASTG12LVCC Design & Technical Manual page 48

Air conditioner wall mounted type refrigerant r410a inverter, indoor/outdoor
Table of Contents

Advertisement

MODEL : AOTG12LV
COOLING
1
Indoor unit is
upper than
outdoor unit.
Height
difference H
(m)
2
Indoor unit is
under than
outdoor unit.
HEATING
1
Indoor unit is
upper than
outdoor unit.
Height
difference H
(m)
2
Indoor unit is
under than
outdoor unit.
Indoor unit
Connection pipe
1 Indoor unit is upper than outdoor unit.
5
15
-
10
-
7.5
-
5
1.014
0
1.023
-5
1.023
-7.5
-
-10
-
-15
-
5
15
-
10
-
7.5
-
5
0.991
0
0.991
-5
0.986
-7.5
-
-10
-
-15
-
Height difference H
Outdoor unit
- (02 - 14) -
Pipe length (m)
7.5
10
-
-
-
0.961
0.988
0.965
0.992
0.969
1.000
0.976
1.000
0.976
1.000
0.976
-
0.976
-
-
Pipe length (m)
7.5
10
-
-
-
0.998
1.000
0.998
1.000
0.998
1.000
0.998
0.995
0.993
0.993
0.991
-
0.988
-
-
Outdoor unit
Indoor unit
Connection pipe
2 Indoor unit is under than outdoor unit.
15
20
0.894
0.895
0.909
0.910
0.912
0.914
0.916
0.918
0.923
0.925
0.923
0.925
0.923
0.925
0.923
0.925
0.923
0.925
15
20
0.955
0.934
0.955
0.934
0.955
0.934
0.955
0.934
0.955
0.934
0.951
0.930
0.948
0.927
0.946
0.925
0.936
0.916

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents