Anritsu HD-1400 Instruction Manual
Anritsu HD-1400 Instruction Manual

Anritsu HD-1400 Instruction Manual

Hd-1400 series, handheld thermometer

Advertisement

INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
HANDHELD THERMOMETER
HANDHELD THERMOMETER
HANDHELD THERMOMETER
HANDHELD THERMOMETER
HD HD HD HD- - - - 1 1 1 1 400 Series
400 Series
400 Series
400 Series
2nd edition Feb., 2012
ANRITSU METER CO., LTD.
2-4-5 Shimomeguro, Meguro-ku,
Tokyo 153-0064, Japan
TEL +81-3-3491-9181
FAX
e1
+81-3-3493-6729

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD-1400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Anritsu HD-1400

  • Page 1 HANDHELD THERMOMETER HANDHELD THERMOMETER HD HD HD HD- - - - 1 1 1 1 400 Series 400 Series 400 Series 400 Series 2nd edition Feb., 2012 ANRITSU METER CO., LTD. 2-4-5 Shimomeguro, Meguro-ku, Tokyo 153-0064, Japan TEL +81-3-3491-9181 +81-3-3493-6729...
  • Page 2 TO ENSURE SAFE AND RELIABLE OPERATION TO ENSURE SAFE AND RELIABLE OPERATION TO ENSURE SAFE AND RELIABLE OPERATION TO ENSURE SAFE AND RELIABLE OPERATION Please observe the following matters t Please observe the following matters to ensure safe o ensure safe Please observe the following matters t Please observe the following matters t o ensure safe...
  • Page 3 Warranty and After Warranty and After sales Service sales Service ANRITSU METER CO., LTD. ships products after severe company’s inspection. Should you find any failure resulting from poor material and workmanship or accident during transportation, please contact the place of purchase or us.
  • Page 5: Table Of Contents

    CONTENTS CONTENTS CONTENTS CONTENTS 1. 1. 1. 1. General General General General ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ e4 2. 2. 2. 2. Unpacking Unpacking Unpacking Unpacking 2.1.Unpacking・・・・・・・・・・・・・・ ・・・・・・・・・・・・・ e4 2.2.Repacking・・・・・・・・・・・・・・・・・・・・・・・・・・・・ e4 3. 3. 3. 3. Name of Components Name of Components Name of Components Name of Components 3.1.Name of Components・・・・・・・・・・・・・・・・・・...
  • Page 6: Unpacking・・・・・・・・・・・・・・ ・・・・・・・・・・・・・ E4

    1. General 1. General 1. General 1. General This handheld thermometer allows easy temperatu- re measurement. These general-purpose thermometers can be used for on-site temperature measurement and various other applications. A microprocessor is used for constant compensation of zero-point and full scale, thus ensuring extremely stable, high precision measurement.
  • Page 7: Name Of Components・・・・・・・・・・・・・・・・・・ E5

    3. Name of Components 3. Name of Components 3. Name of Components 3. Name of Components 3.1. Name of Components 3.1. Name of Components 3.1. Name of Components 3.1. Name of Components (MODEL: HD D D D - - - - 145 (MODEL: H 1450 0 0 0 ) ) ) ) (MODEL: H...
  • Page 8: Display Of All Segments ・・・・・・・・・・・・・・・・ E6

    3.2. 3.2. Display of all segments Display of all segments 3.2. 3.2. Display of all segments Display of all segments ① ② ③ ④ ⑤ Battery Indicator ① Main Display ② ③ ℃ Hold ④ Auto Power OFF ⑤...
  • Page 9: Battery Installation ・・・・・・・・・・・・・・・・・・・ E7

    4. Preparation for Operation 4. Preparation for Operation 4. Preparation for Operation 4. Preparation for Operation 4.1. Battery Installati 4.1. Battery Installati 4.1. Battery Installati 4.1. Battery Installation Be sure to keep the power OFF during the battery cells change. (1) Remove the two screws (2) Set battery cells and detach the battery...
  • Page 10: How To Use Hand Strap・・・・・・・・・・・・・・・・・ E8

    ●The Reset switch is a small push button in the upper section of the battery housing. Use a thin stick to lightly press it. Please do not push with the breakable object. ※To maintain waterproof properties, make sure that the battery housing cover is not partially open when reattaching the battery housing cover.
  • Page 11: Sensor Setting・・・・・・・・・・・・・・・・・・・・・・・・ E9

    Set the sensor as shown. The plug is so designed that it will not be set when the polarity is reversed. Forcible insertion will damage the instrument. Be sure to check the polarity. [HD-1400] [HD-1450] 4.4. Soft case . Soft case . Soft case .
  • Page 12: Power On / Off・・・・・・・・・・・・・・・・・・・・・・ E10

    5. Operation 5. Operation 5. Operation 5. Operation 5.1. Power ON 5.1. Power ON 5.1. Power ON 5.1. Power ON/ / / / OFF Press the Power key to turn power ON and all segments appear on the display for 1 second, and start measurement as be shown below.
  • Page 13: Automatic Power Off ・・・・・・・・・・・・・・・・ E11

    5.3. Automatic Power OFF 5.3. Automatic Power OFF 5.3. Automatic Power OFF 5.3. Automatic Power OFF Press the AUTO OFF key to enter the Automatic Power OFF mode that is provided to automatically turn Power OFF after a certain period times (about 5 minutes) no key operation.
  • Page 14: E12

    7. Indicator of Battery remain 7. Indicator of Battery remain 7. Indicator of Battery remain 7. Indicator of Battery remain The battery level is indicated in the upper section of the display. In accordance with operation hours, the indicator lights go out as shown below. Battery level Battery level Battery level...
  • Page 15: Indication Of Sensor Burnout・・・・・・・・・・ E13

    8. Error Messages 8. Error Messages 8. Error Messages 8. Error Messages 8.1. Indication of Sensor Burnout 8.1. Indication of Sensor Burnout 8.1. Indication of Sensor Burnout 8.1. Indication of Sensor Burnout If the sensor burns out or is not coupled, the Burnout display appears shown as left.
  • Page 16: Indication Of Error・・・・・・・・・・・・・・・・・・・ E14

    8.3. Indication of Error 8.3. Indication of Error 8.3. Indication of Error 8.3. Indication of Error The instrument is broken, please contact the place of purchase or us. 8.4. Indication of Exhausted 8.4. Indication of Exhausted 8.4. Indication of Exhausted 8.4.
  • Page 17: Maintenance Maintenance

    9. 9. 9. 9. Maintenance Maintenance Maintenance Maintenance 9.1. Storage 9.1. Storage 9.1. Storage 9.1. Storage Avoid places subject to the following when storing the instruments. Direct Sunlight ● Strong vibration ● High humidity (85%RH or more) ● Hot atmosphere (50℃ or more) ●...
  • Page 18: In Case Of Trouble

    10 10 10 10. In case of Trouble . In case of Trouble . In case of Trouble . In case of Trouble Issues of instruments operation trouble, please check follows. If your trouble is not solved, please contact the place of purchase or us. (1) Display does not show any segments.
  • Page 19: E17

    11. Specification 11. Specification 11. Specification 11. Specification Display 7 segments LED Operation key Membrane switch Water-resistant Equivalent to IPX5 construction Linearizer Digital (based on JIS C 1602-1995) Sampling rate Approximately 300 ms Signal source 500Ω resistance Power supply Battery cells (AA) 4 pieces or AC adaptor Battery life Approximately 150 h...
  • Page 20 Accuracy Accuracy Accuracy Accuracy Measurement 1℃ -205~805℃ range 0.1℃ -104.9~504.9℃ 0 0 0 0 ℃ ℃ ℃ ℃ or more or more Accuracy or more or more 1℃ ±(0.1% of reading + 1℃) resolution Below 0 Below 0 Below 0 Below 0℃...