Download Print this page
Knox KNOXBOX 3200 Installation Instructions

Knox KNOXBOX 3200 Installation Instructions

Multi-purpose electrical switch

Advertisement

Quick Links

MULTI-PURPOSE ELECTRICAL SWITCH
INSTALLATION INSTRUCTIONS FOR KNOXBOX® 3200 & KNOXVAULT® 4400
KnoxBox 3200 Mounting Configuration
Backplate shown without housing for clarity
Mounting
Screws
Key Hook
Bracket
KnoxVault 4400 Mounting Configuration
Switch Assembly REPLACES Right Key Hook Bracket - No Shared Holes
Backplate shown without housing for clarity
1601 W. DEER VALLEY RD. PHOENIX, AZ 85027
©Knox Company. All rights reserved.
Mounting
Screws
Key Hook
Bracket
Switch
Assembly
Wire Exit
Opening
Switch
Assembly
Wire
Exit Opening
|
T.
800-552-5669
|
This electric switch may be connected to most electric
doors including those equipped with Maglock-type
locks. Gates and other electrical equipment may also be
operated by this switch.
Typically, the switch will be used to unlock electrical doors
and gates that are controlled by a low voltage circuit.
Other devices may require an intermediate control relay
for use with higher voltages.
IMPORTANT
The maximum load for this electrical switch is:
28 Volt AC/DC 5 Amp
This switch may be retrofitted into all KnoxBox 3200
units sold since April 2002 and KnoxVault 4400 units
sold since January 2003.
MOUNTING BRACKET ORIENTATION –
KNOXBOX 3200 VS. KNOXVAULT 4400
Please note that the switch and label orientation
remain the same, only the bracket is reversed to
accommodate mounting differences. The switch can
be rotated when installed to allow for normally open or
normally closed circuits.
KnoxBox 3200
NORMALLY OPENED VS. NORMALLY
CLOSED SWITCH OPERATION
Switch units may be oriented to achieve either a normally
open or normally closed use. Upon installation, the switch
must be inserted into its mounting hole so that the switch
label will read correctly and the switch circuit will operate
correctly when in use.
Retaining
Washer Faces
OPEN
Position
Terminals Face
LOCKED Position
Normally Closed Circuit
F.
623-687-2290
|
INFO@KNOXBOX.COM
KnoxVault 4400
Retaining
Washer Faces
LOCKED
Position
Terminals Face
OPEN Position
Normally Open Circuit
|
KNOXBOX.COM
OPE-MTGINS-0107-C

Advertisement

loading

Summary of Contents for Knox KNOXBOX 3200

  • Page 1: Mounting Bracket Orientation

    The maximum load for this electrical switch is: 28 Volt AC/DC 5 Amp Switch Assembly This switch may be retrofitted into all KnoxBox 3200 units sold since April 2002 and KnoxVault 4400 units sold since January 2003. MOUNTING BRACKET ORIENTATION –...

This manual is also suitable for:

Knoxvault 4400