Quest Dry RDS 10
Quest DRY 150
Installation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
– Read and Save These Instructions –
This manual is provided to acquaint you with
the dehumidifier so that installation, operation
and maintenance can proceed successfully.
Ultimate satisfaction depends on the quality
of installation and a thorough understanding
of this equipment. The dehumidifier is built
around tested engineering principles and has
passed a thorough inspection for quality of
workmanship and function.
Quest Dry RDS 10:
• Roto-mold design
• 80 pints per day at 80ºF/60%RH (AHAM)
(10 Gallons)
• 5.1 amps of power
• 12-inch recessed wheels
• Telescoping handle
• Solid state control panel
• Multiple ducting options
• Stackable design
• Lightweight
quest
quest
quest
quest
Specifications subject to change without notice.
Patent 7,246,503
Water Removal Rate (Pints/Day)
80 pints
4201 Lien Rd
Madison, WI 53704
www.QuestOnTheJob.com sales@QuestOnTheJob.com
1
80˚F, 60% (AHAM)
Phone 608-237-8400
Toll-Free 1-866-933-7476
4037498
04/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dry RDS 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quest Engineering Dry RDS 10

  • Page 1 Quest DRY 150 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions – Read and Save These Instructions – – Read and Save These Instructions – This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
  • Page 2: Table Of Contents

    Quest Dry RDS 10 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions Table of Contents Safety Precautions ..........3 1. Safety Certifications ........4 2. Specifications ..........4 3. Operation ............. 4 3.1 Transporting ..........4 3.2 Electrical Requirements ......
  • Page 3: Safety Precautions

    Quest Dry RDS 10 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions Safety Precautions Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from your Quest Dry RDS 10.
  • Page 4: Safety Certifications

    It is recommended the units are properly secured for transport. The Quest Dry RDS 10 must always be upright when transported by vehicle. It may be tipped onto its handle and back for loading and moving by hand.
  • Page 5: Electrical Requirements

    3.2 Electrical Requirements The Quest Dry RDS 10 plugs into a common grounded outlet on a 15 amp circuit. It draws 5.1 amps at 80°F, 60% RH. If used in a wet area, a ground fault interrupter (GFI) is required. If an extension cord is required, it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 feet long.
  • Page 6: Hour Meter

    4.2 Storage There are two issues to consider when the Quest Dry RDS 10 is stored between uses and both pertain to the water trapped in the unit: damage caused by freezing or biological growth. The effect of the trapped water can be greatly reduced if precautions are taken to remove as much as possible before storage.
  • Page 7: Service

    CAUTION: Do not operate unit without the front housing in place. 5.1 Technical Description The Quest Dry RDS 10 uses a refrigeration system similar to an air conditioner’s to remove heat and moisture from incoming air and to add heat to the air that is discharged.
  • Page 8 Quest Dry RDS 10 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions Some dehumidification, air mover runs continuously but compressor only runs sporadically. 1. Unit is in defrost cycle, DEFROST light on 2. Defrost thermistor defective or loose 3.
  • Page 9: Air Mover

    Quest Dry RDS 10 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions Unit pumps water automatically but not when PURGE button is pushed. 1. Bad connection in PURGE button circuit 2. Defective control board Evaporator coil frosted continuously, low dehumidifying capacity.
  • Page 10: Condensate Pump

    Quest Dry RDS 10 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions 5.5 Condensate Pump The internal condensate pump removes water that collects in the reservoir. To replace the condensate pump: 1. Unplug the unit 2.
  • Page 11: Wiring Diagram

    Quest Dry RDS 10 Quest Dry RDS 10 Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions 7. Wiring Diagram THERMISTOR BLU-14 WHT-2 BLK-4 CONTROL BOARD LEVEL COMPRESSOR SWITCH CONDENSATE PUMP BLU-18 4026354 C BLOWER MOTOR Figure 7 quest...
  • Page 12: Service Parts

    Quest Dry RDS 10 Installation, Operation and Maintenance Instructions 8. Service Parts Item Description Part No. Items listed are not shown Top Cover 4026977 Description Part No. Compressor 4029567 Top Cover Hinge 4026978 Evaporator Coil 4028234 Top Cover Catch 4026979...
  • Page 13: Warranty

    (but all warranty periods will be extended by the period of time, if any, that the Quest Dry RDS 10 Dehumidifier is out of service while awaiting covered warranty service).

Table of Contents