Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is Class 1 and must be connected to
an Earth circuit
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge. If you are in any doubt,
please consult a qualified electrician.
This light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of
the connections.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
6W LED Module - 6000K/600lm
IP rating:
44
Layout
• Plan the desired layout of this fitting carefully,
ensuring the cables will reach the distance between
the junction box and the light fitting
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged
• Cables in walls must be protected using suitable
conduit or plastic trunking.
This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
be scrapped.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is rated at IP44.
This product is not suitable for dimming.
The entire unit gets hot whilst on for a period of time.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• This product has special protection against the
ingress of moisture and is IP44 rated.
Installation & Wiring
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting, carefully note the position of each set
of wires.
• Remove the lampshade from the product using a
screwdriver.
• Unscrew Screw A and remove the Transparent
Terminal Cover.
SUPPLYL
Diffuser
SWITCHED LIVE
NEUTRAL (BLUE)
EARTH (GREEN/YELLOW)
Terminal
Cover
Check that...
• You have correctly identified the wires.
• The connections are tight.
Commissioning
• Reattach the terminal cover and diffuser.
• Replace fuse or circuit breaker and switch on. Your
light is now ready for use.
• Hold the product in position and mark the location
of the fixing holes. Sensor must be at the base, as
shown below..
• Thread the cable through the rubber grommet in the
back plate.
• Fix the wall back to the wall using the screws
and plugs supplied. Ensure the wall is capable of
holding the weight of the product. Take care to avoid
damaging any concealed wiring and pipes. The
correct fixings should be used for brick or cavity
walls.
• Wire as detailed below.
IGHT FITTING
BROWN (L)
Wiring Colours :-
L (Live) - Brown
NEUTRAL (N)
N (Neutral) - Blue
Earth - Green/
GREEN/YELLOW
Yellow
• No loose strands have been left out of the connection
block.