Gossen MetraWatt Sineax TI 816 Operating Instructions
Gossen MetraWatt Sineax TI 816 Operating Instructions

Gossen MetraWatt Sineax TI 816 Operating Instructions

Passive dc signal isolator

Advertisement

Quick Links

Safety precautions to be
strictly observed are marked
with following symbols in the
operating instructions:
Contents
1. Read first and then ... .................................................................................... 1
2. Scope Of Supply ............................................................................................. 1

3. Brief description ............................................................................................ 1

4. Versions ......................................................................................................... 1

5. Technical data ............................................................................................... 1

6. Mounting ........................................................................................................ 2
7. Electrical Connections ................................................................................... 2
8. Commissioning And Maintenance ................................................................. 2
9. Releasing The Signal Isolator .......................................................................... 2
10. Dimensional Drawings ................................................................................... 2
1. Read first and then ...
The proper and safe operation of the device assumes that
the operating instructions is read carefully and the safety
warnings given in the various Sections
6. Mounting
7. Electrical connections
are observed.
The device should only be handled by appropriately trained
personnel who are familiar with it and authorised to work
in electrical installations.
2. Scope of supply
Signal isolator (Fig. 1)
1 ea. operating instructions (Fig. 2) in English, French, German
Fig. 1
3. Brief description
The signal isolator SINEAX TI 816 serves to electrically insulate an analogue DC
signal in the range 0...20 mA which depending on version is then converted to a
current or voltage signal (0...20 mA or 0...10 V). It does not require a separate power
supply.
Fig. 2
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Phone +41 56 618 21 11
Fax +41 56 618 24 58
e-mail: cbag@gmc-instruments.com
http://www.gmc-instruments.com
The instrument fulfils all the important requirements and regulations concerning
electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was
developed and is manufactured and tested in strict accordance with the quality
assurance standard ISO 9001.
4. Versions
There are two versions of the DC signal isolator SINEAX TI 816 available.
Description
Passive DC signal isolator
input signal E: 0...20 mA,
with 1 isolation and
transmission channel, in
carrying rail housing N12
5. Technical data
Input signal E
DC current:
Max. permissible current:
Voltage limiter:
Voltage drop:
Overshoot:
Output signal A
DC current or
DC voltage:
Limit:
Max. burden:
Internal resistance:
Residual ripple:
Time constant:
Accuracy data
Error limits:
Ambient conditions
Operating temperature::
Storage temperature:
Annual mean
relative humidity:
Seismic test:
Shock test:
1
With current signal
2
With voltage signal
1
Operating Instructions
Passive
DC signal isolator
SINEAX TI 816
TI 816-5 Be
996 118 5000-10.00
Output
Order code
signal A
0...20 mA
816-5110
0...10 V
816-5111
0...20 mA
50 mA
18 V ± 5% (with zener diode)
< 2 V (for 500 Ω burden)
< 20 µA (typical 5 µA)
0...20 mA or 0...10 V
Approx. 30 mA
1
2
Approx. 15 V
600 Ω
1
500 Ω
2
< 20 mV ss
Approx. 5 ms
< ± 0,1%
1
(reference value 20 mA,
linearity error included)
< ± 0,2%
2
(reference value 10 V,
linearity error included)
–20 to + 65 °C
–40 to + 85 °C
≤ 75% Standard climatic rating
5 g, < 200 Hz, 2 h in each of 3 directions
50 g, 10 shocks in each of 3 directions
Order No.
990 722
994 089

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sineax TI 816 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gossen MetraWatt Sineax TI 816

  • Page 1 4. Versions ......................1 4. Versions 5. Technical data ....................1 6. Mounting ......................2 There are two versions of the DC signal isolator SINEAX TI 816 available. 7. Electrical connections ................... 2 8. Commissioning and maintenance ..............2 Description...
  • Page 2 6. Mounting Connect the input and output leads E and A according to Fig. 6. The SINEAX TI 816 isolator is suitable for mounting on two different types of standard rails: – onto the G-type rail EN 50 035-G32 – onto the top-hat rail EN 50 022-35 × 7.5.

Table of Contents