Advertisement

200 Shadylane Drive
Philipsburg, PA 16866
www.druckerdiagnostics.com
Service Manual
Horizon 24 Flex Centrifuge
DRUCKER DIAGNOSTICS
SM029
1
HORIZON 24 FLEX SERVICE MANUAL
REV A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Horizon 24 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Drucker Horizon 24

  • Page 1 200 Shadylane Drive Philipsburg, PA 16866 www.druckerdiagnostics.com Service Manual Horizon 24 Flex Centrifuge DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 2: Table Of Contents

    Contents PREFACE INTENDED USE GENERAL DESCRIPTION OF MAJOR COMPONENTS WARRANTY INFORMATION SPECIFICATIONS TROUBLESHOOTING SERVICE INSTRUCTIONS WIRING DIAGRAM SPARE PARTS LIST DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 3: Preface

    Failure to follow the procedures in this document may result in personal injury or instrument damage. Drucker Diagnostics will not be held liable for any injury or damage because of improper servicing.
  • Page 4: Specifications

    Tighten rotor screw per section 7-2 PROBLEM POSSIBLE CAUSE SOLUTION Debris in air intake / exhaust ports Remove power before clearing debris. Whistling noise while running Gasket failure Requires service DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 5: Service Instructions

    Rotor damaged Replacement required ‘ROTOR’ Software selection of rotor is unknown Service Required – Call Drucker technical service. 7. SERVICE INSTRUCTIONS 7.1. Cleaning • The cabinet, rotor and accessories can be cleaned using soap and water, isopropyl alcohol, or a 10% (5500 PPM) bleach solution •...
  • Page 6 – do not over tighten. Each nut sets the height of a separate control panel button. Too low, and they cannot be actuated, too high and they jam against DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 7 Attach the motor to the motor mount plate with four #8 screws and torque to 18 in-lbs (Fig 2). • Secure the motor wire harness with a zip tie as shown. Snip the tag end of the zip tie flush when complete. DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 8 (fig 7). • Install one fender washer onto each stud (fig 8). • Finish the assembly with one Nylok nut on each stud, and tighten to 13 in-lbs DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 9 Secure the base with six #8 screws torqued to 10 in-lbs. (fig 11). • Install the exhaust cover and secure with three #8 screws torqued to 10 in-lbs. (fig 12). DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 10 Carefully place the cabinet onto the base taking care not to pinch any wires between the two. • Complete the assembly by replacing the eight #8 screws, with a 3/32 hex key. DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 11: Wiring Diagram

    8. WIRING DIAGRAM DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...
  • Page 12: Spare Parts List

    9. SPARE PARTS LIST DRUCKER DIAGNOSTICS SM029 HORIZON 24 FLEX SERVICE MANUAL REV A...

Table of Contents