Download Print this page

Air Cylinder; Clamp/Unclamp Sensors; Turret Die Springs - Haas ST-10/30 Troubleshooting Manual

Turret indexer assembly

Advertisement

Turret Indexer Assembly - SL-10/30 ST-10/15 - Troubleshooting Guide

Air Cylinder

Clamp/Unclamp Sensors

Turret Die Springs

Corrective Action:
With the turret clamped test the air cylinder for
faulty piston seal.
Remove the upper hose (unclamp) on the cylinder.
If air is escaping from the upper hose (unclamp)
connection on the cylinder the cylinder piston seal
is bad and piston should be replaced.
Corrective Action:
Check the turret unclamp and clamp sensors.
Use a magnet and pass it over the sensors. Watch
the diagnostics screen to make sure they activate
with the magnet.
If the magnet did not activate the sensors inspect
the cables. If the cables are not damaged then the
sensor will need to be replaced.
If the sensors were activated then they may need to
be adjusted. Verify the motor coupler alignment
before adjusting sensors. Refer to
SL-10-30, TL-15/25, HL-1-6 - TURRET LOCK AND
UNLOCKED SENSORS - ADJUSTMENT
Corrective Action:
With the turret clamped, rotate the turret back and
forth by hand. If there is movement in the turret the
die springs are broken and need to be replaced.
Refer to
HL/SL/ST-10 - TURRET -
REPLACEMENT
removed the springs can be replaced.
Page 4 of 5 pages
ST-10/10Y,
procedure.
from the manual. Once the turret is

Advertisement

loading

This manual is also suitable for:

St-10/15