DIMENSIONS AND INSTALLATION
GROUNDING THE REFRIGERATOR
IMPORTANT—PLEASE READ CAREFULLY
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
The power supply cord of this appliance is
equipped with a three-prong (grounding) plug
which mates with a standard three-prong
(grounding) wall receptacle to minimize the
possibility of electric shock hazard from this
appliance.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility
and obligation to have it replaced with a properly
grounded 3-prong wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG FROM
THE POWER CORD.
DO NOT USE AN ADAPTER PLUG
TO CONNECT THE REFRIGERATOR
TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD
WITH THIS APPLIANCE.
For answers to your Monogram, GE Café
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
INFORMATION
SIDE PANELS
Side panels (not supplied)
must be used whenever
the sides of the refrigerator
will be exposed. The 1/4"
side panels will slip into
the side case trim. Order
side panels from your
cabinet manufacturer.
* Depending on installation
height.
FLOORING
For proper installation, this refrigerator must be
placed on a level surface of hard material that
is at the same height as the rest of the flooring.
This surface should be strong enough to support
a fully loaded refrigerator, or approximately 1500
lbs.
NOTE: Protect the finish of the flooring. Cut a
large section of the cardboard carton and place
under the refrigerator where you are working.
WATER AND ELECTRICAL LOCATIONS
The opening must be prepared with the
electrical and water supply located as shown.
THE CUTOUT DEPTH MUST BE 24"
The refrigerator will project forward, slightly
beyond adjacent cabinets, depending on your
installation.
Series, GE Profile
®
Service, 800.626.2000.
THE INSTALLATION SPACE
24"
*84"
*3" to 4"
1-1/2"
ADDITIONAL SPECIFICATIONS
A 120 volt, 60Hz, 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not
recommended.
Water line can enter the opening through the floor or
rear wall. The water line installed should be 1/4" O.D.
copper tubing or GE SmartConnect™ tubing between
the cold water line and water connection location. The
line should be long enough to extend to the front of the
refrigerator. Installation of an easily accessible shutoff
valve in the water line is required.
Series or
3"
*Finished Width
7"
Electrical
84 1/2" max
Area
83 1/2" min
Finished
Opening
of Electrical
24"
Water
5"
5"
Supply
3 1/2"
3 1/2"
Total volume and shelf
Listed by
area are calculated by
Underwriters
the Association of Home
Laboratories
Appliance Manufacturers'
standards.
7"
74"
From Floor
to Bottom
* The finished
cutout width must
be: 41-1/2" for
42" models
Specification Revised 3/16

Advertisement