Intech Micro 2100-R2 Installation Manual page 4

Rev 1.0
Table of Contents

Advertisement

2100-R2 Specifications.
Input:
Digital Outputs:
-Functions
-Contact Material
-Relay Ratings
-Number of Operations
Power:
-H
-M
-L
Safety and EMC Compliances:
EMC Emissions Compliance
EMC Immunity Compliance
Safety Compliance
Mains Isolation
Mains Isolation Test Voltage
Isolation Test Voltages:
General Specifications: (Unless otherwise stated in other input specifications.)
RF Immunity
Operating Temperature
Storage Temperature
Operating Humidity
Housing
-Material
-Dimensions
-Mounting
-Weight
Note 1. Contact INTECH INSTRUMENTS for more detailed programming information.
Product Liability. This information describes our products. It does not constitute guaranteed properties and is not intended to affirm the suitability
of a product for a particular application. Due to ongoing research and development, designs, specifications, and documentation are subject to
change without notification. Regrettably, omissions and exceptions cannot be completely ruled out. No liability will be accepted for errors, omissions
or amendments to this specification. Technical data are always specified by their average values and are based on Standard Calibration Units at
25C, unless otherwise specified. Each product is subject to the 'Conditions of Sale'.
Warning: These products are not designed for use in, and should not be used for patient connected applications. In any critical installation
an independant fail-safe back-up system must always be implemented.
CAUTION:
Dangerous Voltages may be present. The 2100-R2 has no user serviceable parts.
2100-R2 Dimensions.
70mm
120mm
Interfaced with the 2100-A
16 Individually Isolated Changeover Relays with LED Indication of Each Output.
When used with a 2100-A
Switching Differential, Auto/Manual, Manual Output Setting, Dual Action Control,
Single Action Control, Heat/Cool, Cool Only, Heat Only.
Silver Alloy
Maximum Rating
250Vac, 2A
125Vac, 2A
110Vdc, 0.3A;
30Vdc, 2A;
250Vac,1/6hp;
125Vac, 1/10hp.
5
2 x 10
Min, at 1A, 250Vac Resistive Load.
85~264Vac/dc; 50/60Hz; 10VA.
23~90Vdc; 10VA.
10~28Vac/dc; 50/60Hz; 10VA.
Refer to '2100-R2 H1 Power Supply Settings' for voltage selection instructions.
EN 55022-A.
EN 50082-1.
EN 60950.
250Vac.
-To all Inputs and Outputs:
-To Earth:
-Interface to Outputs
-Between Outputs:
<±1% Effect FSO Typical.
0~60C.
-20~80C.
5~85%RH Max. Non-Condensing.
ABS Inflammability V0 (UL94)
L=195, W=120, H=70mm.
35mm Symmetrical Mounting Rail.
800g. Includes Packaging.
Protective enclosure only to be opened by qualified personnel.
Remove ALL power sources before removing protective cover.
120mm
or 2100-A
.
16
4
, the relays can be used as Set Point (SV)
16
Approved to Standard
UL
CSA
3000Vac 50Hz for 1min.
1500Vac 50Hz for 1min.
3000Vac 50Hz for 1min.
1500Vac 50Hz for 1min.
195mm
2100-R2 Relay Expander
2100-R2 Relay Expander
2100-R2 Relay Expander
2100-R2 Relay Expander
2100-R2 Relay Expander
Serial No.
Serial No.
Serial No.
Serial No.
Serial No.
14.08-4
.

Advertisement

Table of Contents
loading

Related Products for Intech Micro 2100-R2

Table of Contents