There may be more than one key number depending on unit. Please keep this information with your records. MODEL#:____________________________ SERIAL#:____________________________ KEY NUMBER(S):_____________________ DATE PURCHASED:___________________ DISTRIBUTOR:_______________________ J.E. Adams Industries 1025 63rd Ave. S.W. Cedar Rapids, IA 52404 1-800-553-8861 www.jeadams.com REV 4-9-12...
Specifications Unit specifications: 9730 Voltage: 120VAC, 60Hz Amperage: (1) 20 amp service (vac motors) and (1) 10 amp service (water side) are required for this unit. Weight: 180 lbs with pallet. Vacuum side: Motors: (2) 120VAC vacuum motor Fuses: (2) 10 amp inline fuses...
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING (THIS APPLIANCE) WARNING – To reduce the risk of fire, electric shock, or injury: • Do not use on wet surfaces. •...
Installation: Water service can come up back channel. Drill holes into concrete surface and install 3/8" studs (4). Bring electrical in underneath can and route NOTE: when mounting, provide clearance up front so cleanout doors can open!! channel to terminal strip. REV 4-9-12...
Page 7
Water service can come up back channel. Terminal strips. Bring BOTH services up through this channel and hook each into a terminal strip. REV 4-9-12...
Once unit has been installed use 5871B8 cap plugs (supplied with unit) to seal holes To attach hose, in canister bottom located in lower cleanout door. Extra cap plugs are included with thread into metal hole the unit in case plug becomes damaged during shipping removal. counter clockwise.
Page 9
Programming: The below timer pictured is the standard SSAC model that allows the end user to select the "coins to start" and the "time per coin" by settings series of dip switches. The number of "coins to start" dip switch is how many quarters are needed to make the machine come on.
Operating Instructions: • Choose function desired and insert payment into that coin mechanism to start function. • Once service is used, hang up hose. Maintenance: • All servicing of machine should be conducted by an authorized service representative! • Filter bags should be accessed and shaken down weekly. It is recommended to keep a new set of bags on hand so that once every few months the bags can be replaced and then laundered.
Page 11
Unit keeps tripping Inadequate wire size ran to machine. Call electrician and install proper wire size for breaker. electrical service versus length or run. Wrong size breaker. Install correct breaker (only if wire size is adequate to handle breaker). Fuses for vac motors keep Inadequate wire size ran to machine.