Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many coun- tries, including the U.S.A. and the E.U.. DLR-TL001 is a trademark of Datalogic S.p.A. and/or its affiliates. All other trademarks and brands are property of their respective owners.
UHF RFID Protocol for Communications at 860 MHz - 960 MHz, Ver- sion 2.0.1 (April 23, 2015). General Information Datalogic RFID DLR-TL001 is a low cost, semi-passive UHF Logger TAG that allows to monitor temperature sensitive products during transportation or storage. DLR-TL001 is compliant to the EPC Class1 Gen2/ISO18000-6C standards, it can be used with the Gen2 UHF RFID readers on the market without requiring any additional equipment.
Telephone Technical Support If you do not have internet or email access, you may contact Datalogic tech- nical support at (541) 349-8283 or check the back cover of your manual for more contact information.
Manual interface behavior The DLR-TL001 tag has a simple manual interface that includes a button, and a bicolor red/green LED that, depending on the configuration, allows to check the status of the alarms and to start/stop the logging activity. By default, the button can be used only to check the status of the tag but not to start/stop the logging activity.
Page 8
• If the battery has not enough charge to continue the logging activity the red or green LED will blink for 2 seconds (the green one in the case of no alarms, red in case of some alarms). DLR-TL001...
Page 9
DLR-TL001 Functional Description Table 1 - Alarm NO ALARM ALARM Temperature Status Green Battery Status Indicator No flashing Flashing If the BE bit is 1 (Start/stop function active), in addition to the behavior described above, the logging activity start can be performed in the following way: •...
"Register Description" on page 14. The DLR-TL001 tag is allowed to define up to 16 different histograms bins. First, for each histogram its counter could be enabled/disabled by a flag bit belonging to the BIN_ENABLE register. The user is able to decide the upper and lower temperature limits for each histogram bin "X": the lower limit of...
Page 12
5 min. to 14 min. and 59 sec. (see Fig. W.3 and Fig. W.4). In this example the samples are not stored in the log memory in order to save memory space. Figure 2 - Cooled example, histogram view DLR-TL001...
The Mean Kinetic Temperature (MKT) is a simplified way of expressing the overall effect of temperature fluctuations during storage, transit, shipment of perishable goods. The DLR-TL001 tag updates the MKT at each new tem- perature sample. The MKT function can be en-/dis-abled toggling the state...
As well as the MKT, the remaining Shelf Life calculation is useful in order to monitor the status of an item during the shipment. The DLR-TL001 calcu- lates the remaining Shelf Life by using a linear approximation of the Arrhe- nius algorithm at each new sampling time.
496 bit for EPC storing. The EPC bank contains the EPC of the DLR-TL001 product that is composed by the Datalogic company prefix, the DLR-TL001 object type and a serial number. The EPC is formatted as a SGTIN-96 code.
0. Default value is 0. 1 - BE (RW) - Button_Enable bit: if 1 the DLR-TL001 button can be used to start and to stop the logging activity. Default is 0.
Page 19
Shelf Life (SHL_TIME) of the product using the Arrhenius equation with linear approximation. Default value is 0. 11 - SD (RW) - Stop_Disable bit: when 1, the DLR-TL001 button cannot be used to stop the logging activity. Default value is 0.
Page 20
Histogram Description tion. If the logging is not stopped before the ETA is reached an alarm is gen- erated. If the value of this register is 0 the ETA alarm feature is disabled. Default value of ETA register is 0. DLR-TL001...
Page 21
Register Description BIN_ENABLE Register (RW) Register Address Default BIN_ENABLE 0x10 0x0001 The register is composed by the following fields: Bit 15 Bit 2 Bit 1 Bit 0 BIN15_EN BIN02_EN BIN01_EN BIN00_EN Default BINX_EN Enable(1)/Disable(0) the counter for the corresponding histogram bin.
Page 22
The lower level of the first bin is fixed to the lower limit of the sensor. The temperature T in °C is expressed in fixed point 8.5 notation Tfixedpoint using the formula: Some sample values are shown in the table below: T (°C) Tfixedpoint 7872 -0,25 8184 1920 DLR-TL001...
Page 23
Register Description BIN_SAMPLETIME Registers (RW - 16 words) Register Address Default BIN_SAMPLTIME_0 0x23 0x0258 BIN_SAMPLTIME_1 0x24 0x0000 ..0x0000 BIN_SAMPLTIME_15 0x32 0x0000 These registers are used to define the sample interval to apply for the next acquisitions in the corresponding bin. The value is expressed in seconds. BIN_THRESHOLD Registers (RW - 16 words) Register Address...
Page 24
Default SHL_THRESHOLD 0x4A 0x0000 Shelf life threshold represents the threshold value for the alarm of the Arrhenius algorithm. If the SHL_TIME value becomes smaller of the Thresh- old value the alarm bit is set. It is expressed in hours. DLR-TL001...
Page 25
0 means minimum capacity. The measurement is performed before each sensor acquisition. If the Battery Level value is 1 (almost discharged) the DLR-TL001 is put automatically in Sleep state. 2 - MEMFULL (RO): bit to 1 to flag a full memory condition.
Page 26
..0x0000 BIN_COUNTER_15 0x65 0x0000 These registers represent the number of temperature samples in the range of the corresponding bin. Default value is 0 for each counter. All the BIN_COUNTER registers are forced to 0 after a reset operation. DLR-TL001...
Page 27
Register Description LAST_SAMPLE_VALUE Register (RO) Register Address Default LAST_SAMPLE_VALUE 0x66 0x0000 It represents the last temperature value read from the sensor (even if not stored in the log memory). LAST_SAMPLE_VALUE register is forced to 0 after a reset operation. SAMPLE_NUM Register (RO) Register Address Default...
Page 28
The samples' timestamps do not need to be saved (it is not required by the example) hence the BIN_SAMPLE_TIME register's flags shall be disabled: BIN_SAMPLE_TIME = 0x0000 The Mean Kinetic Temperature and the Shelf Life registers can be left to the default value since we don't need to use it. DLR-TL001...
Page 29
Register Description In order to activate the tag and put it in Idle state the initial date configura- tion register (INIT_DATE) shall be written with a non-zero value and the tag shall be reset using the dedicated bit in the INIT_DATE Register at page 15. In this state the internal clock is active and the tag is waiting for a start log- ging command (LE in the STATUS register).
For installation, use and maintenance, do not open the Logger Tag DLR- TL001. The DLR-TL001 is not user-serviceable. Opening the case of the unit can cause internal damage and will void the warranty. WEEE Statement For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.datalogic.com.
Page 32
Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center, with shipping charges prepaid. Datalogic shall pay for the return of the product to Customer if the ship- ment is to a location within the country in which the Datalogic service center is located.
Page 33
Datalogic service personnel or its authorized representatives; (ii) any claimed defect, failure or damage which Datalogic determines was caused by faulty operations, improper use, abuse, misuse, wear and tear, negligence, improper storage or use of parts or accessories not approved or supplied by Datalogic;...
Da-talogic shall assume risk of loss or damage for product in Datalogic's possession. In the absence of specific written instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.