50Hz Quest CDG 114 Quest Dry Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions – Read and Save These Instructions – This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
50Hz Quest CDG 114 Installation, Operation and Maintenance Instructions Safety Precautions Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from your Quest CDG 114.
Optimum performance will be observed between the temperatures of 21°C and 35°C. 2.1 Transporting The Quest CDG 114 features a high impact roto-molded housing with 30cm recessed wheels and a telescoping handle. The rugged roto-molded housing protects the dehumidifier from damage. The 30cm wheels provide greater maneuverability and roll over obstacles with ease.
2.2 Electrical Requirements The Quest CDG 114 plugs into a 230V common grounded outlet. It draws 3.7 amps at 26.7ºC, 60% RH. If used in a wet area, a ground fault interrupter (GFI) is required. If an extension cord is required, it must have a minimum of 18 gauge conductors if 6m long or less and 16 gauge conductors if greater than 6m long.
This temperature range is often found during the first 24 hours of a drying job. Above 32ºC - When the Quest CDG 114 is used in high temperature conditions above 32ºC, reposition the bypass cover to open the bypass holes, figure 4.
3.2 Storage and Freeze Protection There are two issues to consider when the Quest CDG 114 is stored between uses and both pertain to water trapped in the unit. The first is biological growth and the second is damage caused by freezing. The effects of the trapped water can be greatly reduced if precautions are taken to remove as much as possible before storage.
50Hz Quest CDG 114 Installation, Operation and Maintenance Instructions 4.1 Technical Description The Quest CDG 114 uses a refrigeration system similar to an air conditioner’s to remove heat and moisture from incoming air and to add heat to the air that is discharged.
Page 9
50Hz Quest CDG 114 Installation, Operation and Maintenance Instructions No dehumidification, air mover runs but compressor does not. Bad connection in compressor circuit Safety float switch closed, check pump reservoir Defective compressor capacitor Defective compressor overload Defective compressor Defective control board Air mover does not run.
50Hz Quest CDG 114 Installation, Operation and Maintenance Instructions Unit pumps water automatically but not when PURGE button is pushed. Bad connection in PURGE button circuit Defective control board Evaporator coil frosted continuously, low dehumidifying capacity. Defrost thermistor loose or defective...
50Hz Quest CDG 114 Installation, Operation and Maintenance Instructions 4.5 Condensate Pump The internal condensate pump removes water that collects in the reservoir. To replace the condensate pump: Unplug the unit Remove the front housing Unplug the pump wires from the wire harness...
50Hz Quest CDG 114 Installation, Operation and Maintenance Instructions 6 Service Parts Description Part No. Filter, 30cm x 30cm x 2.5cm 4025568 Hose (1/4” ID x 10m long) 4024916 Control Board 4028255 Capacitor, Compressor, 30 μF 4033032-02 Capacitor, Impeller, 4 μF...
Year One: Therma-Stor LLC warrants that, for one (1) year the Quest CDG 114 dehumidifier will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the defective part(s), free of any charge.