RKC INSTRUMENT COM-JL Quick Instruction Manual

Ethernet [modbus/tcp] communication converter
Hide thumbs Also See for COM-JL:

Advertisement

Quick Links


Ethernet [Modbus/TCP] Communication Converter
Quick Instruction
COM-JL
Manual
[For SRZ]
IMR01Y29-E2
All Rights Reserved, Copyright  2007, RKC INSTRUMENT INC.
This manual describes the basic operation method of the COM-JL. For the installation, the
communication data, the detail handling procedures and various function settings, please
refer to the following separate manuals.
 COM-JL [For SRZ] Installation Manual (IMR01Y25-E):
Attached to the product
 COM-JL [For SRZ] Communication Data List (IMR01Y33-E):
Attached to the product
 COM-JL [For SRZ] Instruction Manual (IMR01Y37-E):
Separate volumes
(Download or sold separately)
The above manuals can be downloaded from the official RKC website:
http://www.rkcinst.com/english/manual_load.htm
1. PARTS DESCRIPTION
Terminal base
Terminal
Indication
cover
lamps 1
Indication
lamps 2
Modular connector
for Ethernet RJ-45
Indication
lamps 3
Terminal
DIP switch 2
cover
Mounting
DIP switch 1
bracket
Front view
Left side view
RX
TX
RUN
FAIL
Indication
lamps 1
Indication lamps 1
[Red]  Instrument normality:
FAIL
Turns off
 Instrument abnormality:
Turns on
[Green]  When normal:
RUN
Turns on
 Operation error:
Flashes slowly
 Data collection just after the power is turned on: Flashes rapidly
TX
[Green] During data send:
Flashes
RX
[Green] During data receive:
Flashes
Indication lamps 2
Link
10BASE-T link:
Amber lamp: ON
100BASE-TX link:
Green lamp: ON
Indication lamps 3
Activity
Half-duplex; activity:
Amber lamp: ON
Full-duplex; activity:
Green lamp: ON
Connector
ETHERNET
Modular connector for Ethernet RJ-45
Switches
DIP switch 1
Set the communication speed for controller communication
DIP switch 2
Do not change this setting
(Use it only in IP address setting by DIP switch)
Others
Terminal cover
Terminal covers above and below the COM-JL
 Used for the DIN rail mounting
Mounting bracket
 When panel mounted, two mounting brackets are required for
the upper and lower sides (one required for the upper side:
sold separately).
Terminal base
Part of the terminal and base of COM-JL
(There is the termination resistor setting switch in the inside of
terminal base)
Mainframe
Part of the mainframe of COM-JL
2. HANDLING PROCEDURES
COM-JL setting
Refer to 3. COMMUNICATION SETTING
 Refer to COM-JL [For SRZ] Installation Manual
Mounting and Wiring
(IMR01Y25-E)
 For controller (SRZ), refer to Z-TIO Instruction Manual
(IMS01T01-E)
 Refer to 4. COMMUNICATION SETTING OF
Controller setting
CONTROLLER
 Refer to Z-TIO Host Communication Quick
Instruction Manual (IMR01T02-E)
IP address setting
Refer to 5. IP ADDRESS SETTING
3. COMMUNICATION SETTING
Do not separate the mainframe from the terminal base with the power turned
Mainframe
on. If so, instrument failure may result.
Controller Communication Speed Setting
Set a communication speed of controller communication.
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Left side
1
2
Controller communication speed
OFF
OFF
38400 bps
ON
OFF
9600 bps
OFF
ON
19200 bps
ON
ON
38400 bps
Factory set value: 19200 bps
3
4
5
6
7
8
OFF
OFF
OFF
OFF
OFF
OFF
Another controller communication setting
Data bit configuration: Data 8-bit, Without parity bit, Stop 1-bit
Do not change the setting of DIP switch 2.
(Use it only in IP address setting by DIP switch)
4. COMMUNICATION SETTING OF CONTROLLER
Set the communication setting of controller (SRZ) as follows.
 Protocol:
Modbus
 Module address:
Z-TIO module: 1 to 16 (Address setting switch: 0 to F)
Z-DIO module: 17 to 32 (Address setting switch: 0 to F)
 Communication speed: 19200 bps (Factory set value)
 Data bit configuration:
Data 8-bit, Without parity bit, Stop 1-bit
For setting method, refer to Z-TIO Host Communication Quick Instruction
Manual (IMR01T02-E) and Z-DIO Instruction Manual (IMR01T03-E).
There are two address settings for the controller (SRZ) connecting to the COM-JL:
continuous setting and free setting. (Set by the COM-JL communication data.)
 For the continuous setting (factory set value), consecutive numbers starting from
1 are set to each controller.
 Free settings can be made in the range of 1 to 31.
5. IP ADDRESS SETTING
Set an IP address of a COM-JL.
For types of IP address setting are available: "setting by Web browser," "setting by Telnet,"
"setting by DeviceInstaller" and "setting by DIP switch." This section describes the only IP
address setting by Web browser.
Confirm the IP address number to the network administrator of the
network (LAN) to which the COM-JL is connected.
If the IP address has been changed from the factory set address (192.168.1.1)
and you do not know the current address, set the IP address using
DeviceInstaller or the DIP switches.
For the IP address setting by Telnet, DeviceInstaller and DIP switch, refer to
COM-JL [For SRZ] Instruction Manual (IMR01Y37-E).
Setting by the Web Browser
It is possible to set the IP address by using the Web browser (such as Internet Explorer).
 Preparations before setting
When setting the IP address by Web browser, it is necessary to coincide the 1st to 3rd
bytes and masking range of the IP address of the client (computer) which starts Web
browser with those of the IP address of the COM-JL.
1. Connect the COM-JL and client, and then turn on the power.
For wiring procedure, refer to COM-JL [For SRZ] Installation Manual
(IMR01Y25-E).
2. The IP address of the COM-JL is set to a factory set value of "192.168.1.1."
As it is necessary to coincide the 1st to 3rd byte values of this IP address with those of
the IP address of the client, change the IP address of the client to "192.168.1. " (:
Any value in the range of 0 to 255, but other than 1).
3. As the subnet mask of the COM-JL is "255.255.255.0," also change the subnet mask
DIP switch 1
of the client to "255.255.255.0."
ON
After the IP address of the server is set, return the present IP address of the
OFF
client to the original address or change to the address meeting the network to be
connected.
It is possible to set the IP address of the COM-JL using the client already
connected to the network. However, as the IP address of the client is
changed, that client is disconnected from the network so far connected.
In addition, when setting the IP address by this method, confirm to the network
administrator whether or not no problem arises.
 Setting example
An example of setting the IP address of COM-JL to "192.168.1.3" is shown in the following.
Screens and operations used in the following explanation are just examples and
dependent on the version of the "XPort" installed on the product.
For details of setting the XPort, please visit the website of Lantronix.
Fixed
1. Start the Web browser; enter the present IP address "192.168.1.1" into the address bar
and then press the Enter key.
2. Web Manager is started and the first screen (Device Status) is displayed.
Click Network in the main menu on the left of the screen.
Click
Do not click any keys except those specified. Device failure and other
problems may occur.
3. Display the Network Settings screen.
Set IP Address to "192.168.1.3" and click OK.
Set
192.168.1.3
Do not change any items other than the IP Address. If so, device failure or
error may result.
4. Clicking the Apply Settings button on the Menu display updates the setting to display
the following message.
Click
5. Enter the new IP address "192.168.1.3" into the address bar as instructed by message
and then press the Enter key. Thus, a new IP address setting screen appears to end the
setting.
6. MODBUS/TCP PROTOCOL
Modbus/TCP is an open field network provided with the Modbus protocol on the TCP/IP
protocol of Ethernet.
The data request side (such as computer) is called "client" and the data response (supply)
side (COM-JL) is called "server."
For details of protocol, refer to COM-JL [For SRZ] Instruction Manual
(IMR01Y37-E).
6.1 Message Configuration
Modbus ADU (Application Data Unit) on TCP/IP is in the following configuration.
Modbus TCP/IP ADU
MBAP Header
PDU (Protocol Data Unit)
7 bytes
2 to 255 bytes
Data
Function code
1 byte
1 to 254 bytes
Transaction
Protocol
Data Length
Unit Identifier
Identifier
Identifier
2 bytes
1 byte
2 bytes
2 bytes

Advertisement

loading
Need help?

Need help?

Do you have a question about the COM-JL and is the answer not in the manual?

Questions and answers

Summary of Contents for RKC INSTRUMENT COM-JL

  • Page 1 Indication Controller Communication Speed Setting (IMR01Y25-E). lamps 2 2. The IP address of the COM-JL is set to a factory set value of “192.168.1.1.” Set a communication speed of controller communication. Modular connector for Ethernet RJ-45 As it is necessary to coincide the 1st to 3rd byte values of this IP address with those of Click the IP address of the client, change the IP address of the client to “192.168.1.
  • Page 2 When the data exceeds the setting Exception code First register address Protocol Identifier High range For the list of register address for the controller, refer to COM-JL [For SRZ] MBAP Header Communication Data List (IMR01Y33-E). Quantity High The setting must be between 1 (0001H) ...