Ip 68 waterproof check-weighing indicator
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
3. Use "0" ~ "9" keys to input the High value. After inputting one digit, the cursor will
move to right. Press "ENTER" key when finishing. (For example 30 kg, press
0030 )
to
When input incorrectly, press "C" key to clear.
4. Press "LO" key, the screen displays the previous setting of Low value.
5. Use "0"~"9" keys to input the Low value, see step 3.
"High value" must be set before "Low value".
6. Put object on the platter, the screen reflects HI / LO / OK status.
If the weight is between the high and low limit, the "OK" zone will blink.
If the weight is over the high limit, the "+" zone will blink.
If the weight is under the low limit, the "-" zone will blink.
02006100
.
The previous setting is 28 kg.