IMI NORGREN VS18G Operation & Service Manual

Valve island vs18 series, vs26 series with ethernet/ip interface
Table of Contents

Advertisement

Quick Links

Valve island VS18/VS26
with EtherNet/IP Interface
Operation & Service
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS18G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IMI NORGREN VS18G

  • Page 1 Valve island VS18/VS26 with EtherNet/IP Interface Operation & Service Manual...
  • Page 2: Construction & Design Is Subject To Change © 2018 Norgren Gmbh

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Change history: The Change history reflects all changes of the Operation & Service Manual, which were done after the initial release. Index Chapters Change description Date Name Set up initial version 07/03/2017 Some corrections were made 21/03/2017 Chapter „Important hints“...
  • Page 3: Table Of Contents

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Content About this documentation .......................... 5 Important hints ............................6 Grounding and equipotential bonding ....................6 Intermediate supply/exhaust module (ISEM) ..................6 ATEX Note ............................6 Power-up and initialization phase of the VS18/VS26 valve island ............. 7 2.4.1 Firmware release V1.001 and lower ...................
  • Page 4 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Contact information Norgren GmbH Site Fellbach Stuttgarter Straße 120 70736 Fellbach Tel: +49 711 5209-0 Construction & Design is subject to change © 2018 Norgren GmbH 09/2018...
  • Page 5: About This Documentation

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP About this documentation This Operation & Service Manual contains the information to set up and operate the VS18/VS26 valve islands with EtherNet/IP interface and to detect and resolve problems. Note: In addition to the specific information for the EtherNet/IP variants, all data sheets for the VS18/VS26 valve island series are applicable and remain valid.
  • Page 6: Important Hints

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Important hints Grounding and equipotential bonding Proper grounding and equipotential bonding are very important to protect against electromagnetic interferences in Ethernet networks. In order to reduce potential impact, grounding of the Ethernet cable screen should be done at both ends of every cable (i.e.
  • Page 7: Power-Up And Initialization Phase Of The Vs18/Vs26 Valve Island

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Power-up and initialization phase of the VS18/VS26 valve island It is possible to read the actual installed firmware release using the Logix-Designer from Allen- Bradley. Please refer to chapter 4.4 for more details. 2.4.1 Firmware release V1.001 and lower The valve island initializes automatically after power-up.
  • Page 8: Mounting Kit 2-In-1

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Mounting kit 2-in-1 Every valve island delivery contains the mounting kit 2-in-1 (part number VS2672971-KG00) as shown in the below figure. This mounting kit can be used to mount the valve island either to the DIN rail or directly to the mounting panel.
  • Page 9: Mounting Panel Assembly Without Mounting Bracket

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 2.5.2 Mounting panel assembly without mounting bracket  Insert screw M4 x 25 (4) into the left end plate (bus node)  Insert screw M4 x 36 (5) into the right end plate ...
  • Page 10: Mounting Panel Assembly Using The Mounting Bracket

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 2.5.4 Mounting panel assembly using the mounting bracket  Hook the mounting bracket (3) into the left end plate (bus node)  Insert screw M4 x 8 (2) into the mounting bracket (3) ...
  • Page 11: Electrical Connections Of The Vs18/Vs26 Valve Islands

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Electrical Connections of the VS18/VS26 valve islands Top view VS18 with 8 stations 1. Port 1 bus connector for EtherNet/IP (4 pins M12 D-coded female connector) 2. Port 2 bus connector for EtherNet/IP (4 pins M12 D-coded female connector) 3.
  • Page 12: Ethernet/Ip Bus Connectors Port 1 & Port 2

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP EtherNet/IP Bus connectors Port 1 & Port 2 M12 / 4 pins / female / D-coded Pin no. Function Transmission Data + (TD+) Receive Data + (RD+) Transmission Data - (TD -) Receive Data - (RD -) Housing FE (functional earth)
  • Page 13: Commisioning

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Commisioning The configuration of the EtherNet/IP valve island is done via inclusion of the device description file (EDS file) „002A002Bxxxx0100.EDS“. The device description file is required to be included for the configuration of the corresponding EtherNet/IP - Controller. Note: xxxx = ‘2000’...
  • Page 14: Hardware Configuration: Select Valve Island

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP In menu “Tool -> EDS Hardware Installation Tool” start the Installation Wizard. Follow the installation steps described in the wizard. After the installation the new module is shown in the catalogue. Hardware configuration: Select valve island After the successful installation of the EDS file, the module configuration is needed.
  • Page 15 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP In the module catalog choose the corresponding VS18/VS26 valve island and click on „Create“. The picture below shows “Select Module Type” – Dialog In the following dialogue tab “General” set the “Name” and the correct “IP Address” of the module. Construction &...
  • Page 16 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP In dialogue tab “Connection” change “Requested Packet Interval (RPI)” greater than or equal to 10 ms and click “OK”. The RPI times has a direct impact to the busload. Note: The lower the cycle times, the higher the busload. The picture bellow shows module tree with the new added module.
  • Page 17: Set Up Ip Address

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Set up IP Address 4.3.1 Using a DHCP Server As default the VS18/VS26 valve island is set up as a DHCP client. In this mode IP Address has to be assigned using a DHCP server or a similar tool. This has to be repeated after each power cycle. The following example shows the IP Address assignment using Rockwell Automations BOOTP_DHCP Tool.
  • Page 18 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Attribute 5 contains the configuration parameters required to operate as a TCP/IP node. At least network address and network mask needs to be configured. Attribute 5 of TCP/IP Interface Object: Interface Configuration Next table shows the structure of the interface configuration attribute Structure of Attribute 5: Interface Configuration Construction &...
  • Page 19: Firmware Version And Serial Number

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Firmware version and serial number It is possible to read the actual installed firmware version and serial number of the device using the Logix-Designer (Allen-Bradley). This information is accessible via the Identity Object (Attribute 3) as described in this section.
  • Page 20 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP The identification and status data of the selected valve island (such as the software version and serial number) are shown in the Tab „Module Info“. Construction & Design is subject to change © 2018 Norgren GmbH 09/2018...
  • Page 21: I/O Connection Via Assembly Object

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP I/O connection via Assembly Object The Assembly Object is used to bundle attributes of different objects, to use only one connection exchanging I/O data. One instance is used for input data and one for output data. Bit allocation valve stations The following picture shows exemplarily a VS island with 6 valve stations.
  • Page 22: Input Data (Assembly Object Instance: 101D)

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP The illustration below shows the assignment for maximum configuration. For every valve two bits will be reserved – one bit for solenoid 14 and one bit for solenoid 12. total valve number byte V 04 V 03...
  • Page 23 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Table: Input – Bit - assignment for VS18/VS26 valve island with 4, 5 - 8, 9 – 12, 13 – 16 and 17 - 20 stations. Valve stations Function 17-20 13-16 9-12 5-8 Byte# UV-VB OV-VB UV-VA OV-VA Module status V04-12 V04-14 V03-12 V03-14 V02-12 V02-14 V01-12 V01-14 Short Circuit / Overload...
  • Page 24: Output Data (Assembly Object Instance: 100D)

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Output data (Assembly Object Instance: 100d) The right picture shows a valve island with 6 valve stations, side 12 is in the front, side 14 is on the backside. Used acronym: „Vnn-ss: nn - valve number [1, 16] ss - solenoid side [12, 14] Example: “V03_12”...
  • Page 25: Solenoid Object

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Solenoid Object Object Class: 100d 1…8 Instances: 4 stations 1…16 5 - 8 stations 1…24 9 - 12 stations 1…32 13 - 16 stations 1…40 17 - 20 stations Each solenoid is a separate instance of the Solenoid Object. The allocation between Instance ID and solenoid is shown in the following table: Valve 1…4 V04-12...
  • Page 26: Diagnostics And Leds

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Diagnostics and LEDs Status LEDs 7.1.1 Status LEDs description LED Name Description Link Port 1 (TX/RX & Link) Link Port 2 (TX/RX & Link) Network Status Module Status Electronic Power Supply Status Valves Power Supply Status 7.1.2 Link states for Port P1 and Port P2 Link Status...
  • Page 27: Electronics Power Supply Status, Led (Vb)

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 7.1.5 Electronics Power Supply Status, LED (VB) Electronics Power Supply States LED State Voltage O.K. green Undervoltage flashing red Overvoltage 7.1.6 Valve Power Supply Status, LED (VA) Valve Power Supply States LED State Voltage O.K.
  • Page 28: Output Behavior In Fault Condition (Idle Mode/Fault Mode)

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Output behavior in fault condition (Idle mode/Fault mode) The Fault Mode defines the behavior of the outputs while communication errors. The VS18/VS26 valve island executes the idle mode if requested by the controller. The following states could be taken by the outputs in case of executing Idle Mode or Fault Mode: ...
  • Page 29: Properties Ethernet/Ip Interface

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Properties EtherNet/IP Interface Specification Comments Number of ports Link Speed 100Mbit/s Duplex Mode Full Duplex QuickConnect DLR Mode Device Level Ring EtherNet/IP (ODVA Certification) Compliant to IEC61158 IP Address modes Static, BOOTP, DHCP EDS languages Construction &...
  • Page 30: Valve Island Extension

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 10. Valve island extension Valve islands can be extended using the 2- and 4-station PCBs as described in this chapter. The following PCBs are available for the extension: VS2672762-KG00 VS2672761-KG00 VS2672764-KG00 4 station PCB 2 station PCB (new) 2 station PCB shall only be mounted at the end in...
  • Page 31: Valve Island With 4 Stations

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 10.2 Valve island with 4 stations 10.3 Valve island with 6 stations Construction & Design is subject to change © 2018 Norgren GmbH 09/2018...
  • Page 32: Valve Island With 8 Stations

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 10.4 Valve island with 8 stations 10.5 Valve island with 10 stations Construction & Design is subject to change © 2018 Norgren GmbH 09/2018...
  • Page 33: Valve Island With 12 Stations

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 10.6 Valve island with 12 stations 10.7 Valve island with 14 stations Construction & Design is subject to change © 2018 Norgren GmbH 09/2018...
  • Page 34: Valve Island With 16 Stations

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 10.8 Valve island with 16 stations 10.9 Valve island with 18 stations 10.10 Valve island with 20 stations Construction & Design is subject to change © 2018 Norgren GmbH 09/2018...
  • Page 35: Usage Of Soft-Start Valves

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 10.11 Usage of Soft-start valves Soft-start valves are only available for VS26. Maximum number of soft-start valves in one valve island is 4. Use always 2 single blank PCBs (VS2672763-KG00) with 1 soft-start valve (VS2672530-KG00). VS2672530-KG00 VS2672763-KG00 Up to 4 soft-start valves may be added at even positions (0, 2, 4, …20, 22, 24).
  • Page 36: Electrical Data

    Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP 11. Electrical data Requirement Comment Valve voltage range (VA) 24VDC +/-10% PELV Electronics voltage range (VB) 24VDC +/-25% PELV Maximal currents: VA: 150mA + n x 30mA n = number of activated valves VB: 400mA Voltages are galvanic decoupled Protection against polarity reversal...
  • Page 37: Technical Data

    Mounting: Sub-base Operating pressure: Maximum pressure 10 bar VS18S / VS26S models and VS18G / VS26G solenoid pilot actuated valves with internal pilot supply 16 bar VS18G / VS26G solenoid pilot actuated valves with external pilot supply Ambient temperature: -15°C to +50°C Medium temperature: -5°C to +50°C (Consult our Technical Service for use below +2°C)
  • Page 38: Technical Data Vs18

    G1/8, NPTF 1/8, PIF 8 mm, PIF 6 mm, PIF 1/4 Valves: ISO 15407-2 - 18 mm Flow – values measured at 6 bar inlet pressure and with a pressure drop of 1 bar: Series Function [L/min] [m³/h] Gal/min] VS18G 0,56 0,48 VS18G 0,56 0,48 VS18S 2x2/2 0,56...
  • Page 39 Operation & Service Manual Valve islands VS18/VS26 EtherNet/IP Customer support Email contact: Anfragen.Ventilteam@imi-precision.com Norgren GmbH Werk Fellbach Stuttgarter Straße 120 70736 Fellbach Tel: +49 711 5209 -0 The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information.

This manual is also suitable for:

Vs26sVs26gVs18s

Table of Contents