WECO Installation Manual HydroSense Reverse Osmosis Water Filter www.wecofilters.com Water Engineering Corporation Long Beach, CA U.S.A 1 (888) 675-5187 sales@wecofilters.com...
Installation Manual INTRODUCTION Congratulations! By choosing WECO Reverse Osmosis (RO) water purification system for your home, you have not only ensured the highest quality, healthy drinking water, you have also selected the most efficient and convenient system in the industry.
Installation Manual Components List Your new WECO Reverse Osmosis System should include the following items. If any item is missing, please contact your supplier, retailer, or any local professional plumbing service. Please take a few moments to check all following components.
Installation Manual Before Installation Before you begin, make sure the installation kit and tools are complete and ready to use. Fig. #2 Tools required for installation: utility knife, Phillips screwdriver, hammer, adjustable wrench, Teflon seal tape, electric drill, and drill bits (1/8”, 1/4” and 7/16”). Before you Begin - Important Notes Important Note: Feed Water Quality - Reverse osmosis drinking water systems are not...
Page 5
Installation Manual Quick Connect EZ Fitting Guide Your Reverse Osmosis Drinking Water Appliance is outfitted with the new generation of userfriendly EZ connect push-in fittings. Proper use of the fittings is shown in the diagrams below. It is important that the tubing selected for use with these connectors be of high quality, exact size and roundness, and with no surface nicks or scratches.
Installation Manual Installation Instructions Pipe Connection: CAUTION The water supply to this reverse osmosis system MUST be from the COLD water line. Hot water will damage the RO system. Before installation, be sure to shut off the house’s main water line. Tapping into the cold water line 1.
Installation Manual Power Supply Installation Locate the power outlet under the sink or near the RO system unit. Make sure the power cord is long enough to reach the power outlet; if not, contact a licensed electrician to install a power outlet.
Installation Manual System Performance and Operating Limits Production Rate GPD (m3/d) 50 GPD Stabilized Salt Rejection Minimum Salt Rejection Feed Water TDS 2000 ppm Max Feed Water Temperature 40 ~ 113 °F Feed Water Pressure 40 ~ 85 psi Feed Water pH 5 ~ 10 Feed Water Hardness <...
Page 11
Installation Manual System NOT Treating Water After Replacing Filter Cartridge Air in the tubing (AIR) Release the air in the tubing Pressurized Motor Continues to Restart Frequently Outlet check valve is not blocking water completely Replace check valve Leakage in the tubing Lock tight/replace tubing Booster Pump Motor Burned Out Abnormal frequent startup and overheat...