LDetek LDP1000 User Manual

Gas purifier for noble gases and nitrogen
Hide thumbs Also See for LDP1000:

Advertisement

LDP1000
Gas Purifier for noble gases and nitrogen
USER'S MANUAL
V1.0
Printed in Canada
Copyright 2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDP1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for LDetek LDP1000

  • Page 1 LDP1000 Gas Purifier for noble gases and nitrogen USER’S MANUAL V1.0 Printed in Canada Copyright 2010...
  • Page 2: Table Of Contents

    LDP1000 User’s manual Table of Content   1. Forwarning ........................2 2. Warranty, maintenance and service policies ..............3   3. Specifications ........................6   4. Cautions and installation information ................6   4.1. Gas line connection ....................6  ...
  • Page 3: Forwarning

    LDP1000 User’s manual 1. Forwarning This manual is required to be read by any user wanted to use the LDP1000 Gas Purifier. It contains important information to successfully operate the instrument. LDetek makes assumption that all operators have taken the time to read this information prior to install, operate and troubleshoot the purifier.
  • Page 4: Warranty, Maintenance And Service Policies

    EXPRESS AND IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY IS THE ONLY WARRANTY MADE BY LDETEK INC. WITH RESPECT TO THE GOODS DELIVERED HEREUNDER, AND NO EMPLOYEE, REPRESENTATIVE OR OTHER PERSON OR ENTITY IS AUTHORIZED TO...
  • Page 5 LDP1000 User’s manual REPLACEMENT UNDER THE STANDARD WARRANTY CLAUSE. IN NO CASE, REGARDLESS OF THE FORM OF THE CAUSE OF ACTION, SHALL SELLER'S LIABILITY EXCEED THE PRICE TO BUYER OF THE SPECIFIC GOODS MANUFACTURED BY SELLER GIVING RISE TO THE CAUSE OF ACTION.
  • Page 6 LDetek Inc. reserves the right to interrupt all business relationship and warranty or service if there is any tentative from any customers to reverse engineering any of LDetek products or to tamper with any sealed module.
  • Page 7: Specifications

    LDP1000 User’s manual 3. Specifications Getter type: Alloy of Zr/V/Fe 2 beds (350 and 200 Celsius) Gases purified: Ar/He/Ne/Xe/Kr. Nitrogen version available. Impurities removed: ,CO,CO ,THC, H , CH (Heated) ,CO,CO (room temperature) Impurity level : <1 ppb for each impurity...
  • Page 8: Lifetime And Led Indication

    7. With the power on the purifier, let the gas vent to the atmosphere for about 3 hours. 5. Lifetime and LED indication The LDP1000 getter has a lifetime of 2 years. However, the red light will indicate when the getter is not purifying the gas anymore. The getter can be replaced instead of the whole purifier.
  • Page 9: Drawings

    LDP1000 User’s manual 6. Drawings Wiring Diagram Cable #4 Heater #2 Cable #5 Heater #1 Cable #2 Thermocouple #1 Red Led Cable #3 Green Led Thermocouple #2 Yellow Led Internal PCB RS-232 Pin A Corcom Pin C Connector Module Pin B...
  • Page 10: Maintenance

    Using a screw driver, remove the front screws on the bottom plate and the top plate, in order to remove the front part of the LDP1000. Step 4 : Remove the front part of the LDP1000 to have access to the inside.
  • Page 11 Step 8 :Put back the wires in the terminal bloc J1 and J2 that you have removed in step 5. Use wiring diagram as reference for the cable #. Step 9 : Re install front part of the LDP1000 and put back the screws that have been removed in step 1.
  • Page 12 LDP1000 User’s manual...

Table of Contents