8-button control keypad, 1-gang box with us or eu/uk faceplate in white or black (40 pages)
Summary of Contents for CYP CDPW-K1S
Page 1
CDPW-K1S UK 1 Gang 9-Button Wall Plate Control Keypad Operation Manual Operation Manual...
Page 3
DISCLAIMERS The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document.
Page 4
SAFETY PRECAUTIONS Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment: • Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
1. INTRODUCTION The Wall-Plate Control System box is a fantastic and useful design for system installer and smart home user. With 9 direct macro buttons and extra 9 macro in WebGUI control which allows up to 18 to be execute within one push and a total of 128 capacity inside this box that can bring out a set of scenes in a seconds.
5. FEATURES • 9 macro buttons and extra 9 macro buttons in WebGUI with up to 128 commands to implant for control system • Supports Relays to control on/off of other devices • Supports Scheduling control system and settings • Supports scheduling memory over power blackout up to 48hrs •...
6. OPERATION CONTROLS AND FUNCTIONS 6.1 Front Panel 1~9 Macro Buttons: Each buttons has 2 colors of LEDs adjustable from dim 0~100% and can be insert up to 16 commands.
6.2 Rear Panel DC 5V: Plug the 5V DC power adaptor included in the package and connect to AC wall outlet for power supply. Control: Connect from PC/Laptop with active internet service or Telnet or WebGUI control with RJ-45 terminated cable. This slots supports PoE PD 48V function which means when the connected server/Hub support PSE 48v it can be powered without DC supply connection.
6.3 Telnet Commands COMMAND NAME DESCRIPTION DESCRIPTION OF PARAMETER IPCONFIG Display The NONE Current IP Configure SIPADDR XXX. Set Ethernet IP XXX=0~255 XXX.XXX.XXX Address SNETMASK XXX. Set Ethernet Net XXX=0~255 XXX.XXX.XXX Mask SGATEWAY XXX. Set Ethernet XXX=0~255 XXX.XXX.XXX Gateway SIPMODE N SET ETHERNET IP N=STATIC/DHCP MODE...
Page 11
COMMAND NAME DESCRIPTION DESCRIPTION OF PARAMETER LEDRED N N1 LED RED N(LEN NO.)=1~8 BACKLIGHT N1=% (0-100) CONTROL LEDBLUES N ALL BLUE LED N=% (0-100) BACKLIGHT CONTROL LEDREDS N ALL RED LED N=% (0-100) BACKLIGHT CONTROL LEDSHOW N LED DIMMING LEDSHOW N MODE CONTROL N=ON/OFF/TOGGLE BACKLIGHT N...
6.4 Software Application Please download the software from www.cypress.com.tw with file name CDPS V2.000 and save it in a directory where you may use it later. Connect the Control System with PC/Laptop through the Ethernet port of an active network system and open the CDPS V2.000 application. Click on Find Devices on Network and a list of the devices connected to the Control System will show up.
6.5 Telnet Control To access the telnet control under MS windows, click ‘Start’ menu and type “cmd” in the search field then press enter. Under Mac OS X, go to Go → Application → Utilities → Terminal See below for reference. Once in the command line interface (CLI) type "telnet", then the IP address, and hit enter.
Page 14
Press “Help” or “?” then hit enter to bring up all available commands. Note: Any commands will not be executed unless followed by a carriage return. Commands are case-insensitive. If the IP is changed then the IP Address required for Telnet access will also change accordingly.
6.6 WebGUI Control On a PC/Laptop that is connected to an active network system, open a web browser and type device’s IP address on the web address entry bar. Note: The Default IP setting is on Static with address at 192.168.1.50 A security page will appear to ask for User and Password, please key in “admin”...
6.6.1 Macro Settings The Background Light Bar allows user with instant change on the LEDs lighting percertanage base on the orignial illuminate setting. There are 6 Macro inserted as default setting for testing the Wall-Plate Control System’s functionality. Click on Macro 1 ~ 6 to demonstrate the function of lighting LEDs.
Page 17
Click on the mark to edit the command settings. Up/down arrows are to move the command up or down and button is to delete the command. Click on Insert button/Add to insert commands. Command can be set to control the Wall-Plate Control Box/SysCMD, other devices connected within the same Telnet system/ Internet area and Releay connected through the Replay outputs of wall- plate Control Box with...
Page 18
delay time. It is suggested the delay time is >100ms once the seetting is confirmed, double click on Save Change. Command set to control the device within the same telnet system or internet area require to set its IP and Port number and it is strongly recommand to set the delay time>500ms in order to secure a successful command sending.
6.6.2 Extension Marco Click on Extension Macro to execute/edit more Macro action up to 9 more. 6.6.3 Command Settings Command under 128 characters including space can be build up to 128 commands, command over 128 characters and under 512 characters including space can be build up to 32 command in addition with 96 commands of 128 characters under.
Page 20
Click on Edit from Repeat column to set the macro command(s) to be activated repeatedly on a set time. Click on Edit from Once column to set the macro command(s) to be activated on a set time only.
6.6.5 Network Settings Click on Network Settings to reset the IP, Netmask or Gateway address. 6.6.6 System Settings Click on System Settings to reset the WebGUI login password and timeout setting and save or download the Macro settings. Reset to Default allows IP and login ID & password to be reset back to factory default.
6.6.7 Time Settings Click on 'Time Settings' to set the system time and to enable/ disable Daylight Saving Time(DST) function. Simply click on the white column and a calendar will appear for your selection with current timing setting. Another simple few clicks to enable/disable DST with its start and end.
8. SPECIFICATIONS Input Ports 9 x Button 1 x Control Output Ports 1 x Relay Power Supply 5VDC/2.6A (US/EU standards, CE/FCC/ UL certified) ESD Protection Human body model: ±8 kV (air-gap discharge) ±4 kV (contact discharge) Dimensions 87mm(W)x87mm(D)x31mm(H) /Jacks Excluded 87mm(W)x87mm(D)x34mm(H) /Jacks Included Weight...