Page 1
ENGLISH Spirotest 100 Model 2016 User manual 32749D01...
Page 2
This publication contains or refers to proprietary information which is protected by copyright. All rights are reserved. Interspiro® and Divator® are registered trademarks belonging to Interspiro. This publication may not be copied, photocopied, reproduced, translated, or converted to any electronic or machinereadable form in whole or...
Spirotest 100 Model 2016 Table of Contents Important information to user ....................5 1. Product description ......................6 1.1 Overview ........................6 1.2 Main components ......................7 2. Preparation ........................9 2.1 Low pressure leakage test ................... 9 2.2 High pressure leakage test ..................9 3.
Spirotest 100 Model 2016 Important information to user WARNING! Do not open the SPIROTEST 100 case while it is powered up. Contact with the powered internal circuitry may lead to death or serious injury. Contact with the moving mechanical parts inside the case can cause considerable injuries.
1. Product description 1.1 Overview The Spirotest 100 Model 2016 is an easy-to-operate, portable test equipment for the testing of breathing apparatus (SCBA), diving apparatus (SCUBA), and chemical protective suits of various types and manufacture. For the operation of the Spirotest 100 Model 2016 further test accessories are required, depending on the equipment to be tested.
Spirotest 100 Model 2016 1.2 Main components Control panel 1. High pressure gauge 10. Vacuum pump button 2. Low pressure gauge 11. Test head inflation button 3. Test connection 12. Test head deflation button 4. Test head 13. Positive pressure button 5.
Page 8
336 290 647 P. Blind cap 336 200 217 * S-mask adapter kit (order no. 98590-01), only included in Spirotest 100 with order no. 33794-02. Tip: Make sure the O-rings on the adapters are well maintained and lubricated. Tip: Mark the different adapters/accessories with “A”, “B”, “C” etc., for easier identification.
Spirotest 100 Model 2016 2. Preparation Before using the Spirotest 100 Model 2016 for testing it must be prepared and function tested, with a Low pressure leakage test and a High pressure leakage test. 2.1 Low pressure leakage test 1. Connect the power cord with plug to a power supply.
If the activating pressure is not according to the value in the test protocol, the warning whistle is defective and must be repaired by Interspiro or by a holder of a valid Interspiro Service Certificate for the equipment in question.
Rising medium pressure indicates leakage from the primary to the secondary side, between the piston and the seat of the regulator. Any such faults are to be repaired by Interspiro or by a holder of a valid Interspiro service certificate for the equipment in question.
Spirotest 100 Model 2016 3.5 High pressure leakage test 1. Close the cylinder valve. 2. Observe the High pressure gauge (1) for 1 minute and record the leakage value in the test protocol. 3. Push Release button (17) to release remaining pressure.
Spirotest 100 Model 2016 4. Test of Spiromatic mask and breathing valve NOTE: A tested and approved regulator is required for all mask and breathing valve tests. 4.1 Safety valve opening pressure for Spiromatic breathing valve 1. Connect HP Adapter 300 bar (B) or HP Adapter 200 bar (C) to the cylinder valve.
Spirotest 100 Model 2016 4.2 Leak test of Spiromatic mask with breathing valve 1. Inflate the Test head (4) slightly by pressing the Vacuum pump button (10) and the Test head inflation button (11). 2. Put mask with breathing valve on to the Test head (4) and firmly tighten the lower straps and head strap (top).
Spirotest 100 Model 2016 4.4 Leak test of Spiromatic breathing valve 1. Connect the breathing valve to the Test connection (3) with Test adapter BV P/Divator (I). 2. Manually activate (ON) the positive pressure lever on the breathing valve. 3. Put Rubber plug (J) in the breathing valve’s hose connection (inlet).
Spirotest 100 Model 2016 4.7 Automatic activation of positive pressure for Spiromatic breathing valve 1. Manually put the positive pressure lever on the breathing valve to the OFF position. 2. Create a negative pressure in the breathing valve by pressing the Vacuum pump button (10) and the Negative pressure button (14) at the same time.
Spirotest 100 Model 2016 5. Test of S mask and breathing valve NOTE: A tested and approved regulator is required for all mask and breathing valve tests. 5.1 Leak test of S mask with breathing valve 1. Inflate the Test head (4) slightly by pressing the Vacuum pump button (10) and the Test head inflation button (11).
Spirotest 100 Model 2016 Troubleshooting Should a not allowed leak occur, generate a positive pressure inside the mask. Locate the leak by using leak detection spray. Tip: The test head can be fully disconnected in order to easily locate any leakage by putting the test head under water.
Spirotest 100 Model 2016 Troubleshooting The positive flow rate is 10 lit/min when testing. For “Hatch” breathing valves – perform the tests in sections 5.5 to 5.6. For “First Breath” breathing valves – perform the test in sections 5.7 to 5.9.
Spirotest 100 Model 2016 8. Remove the grey part of the Test adapter MPE-P2 (K) in order not to damage the Low pressure gauge (2). 9. Close the cylinder valve. 10. Disconnect Test adapter MPE-P2 (K) and Adapter breathing valve #2 (N) from the breathing valve.
Spirotest 100 Model 2016 5.9 FIRST BREATH - Air supply capacity for S breathing valve 1. Connect Test adapter MPE-P2 (K) to the Test connection (3). 2. Connect the black tube of the Test adapter MPE-P2 (K) to the Adapter breathing valve #2 (N).
Spirotest 100 Model 2016 6. Leak test of complete apparatus with mask 1. Connect the breathing valve to the mask. 2. Manually activate (ON) the positive pressure lever on the breathing valve (First breath version), or close the hatch on the mask (Hatch version).
Spirotest 100 Model 2016 7. Technical Data Width 400 mm Depth 380 mm Height 340 mm Weight 16.5 kg (excl. test adapters and accessories) Mains supply 110-220 V AC/50-60 Hz...
Need help?
Do you have a question about the Spirotest 100 and is the answer not in the manual?