Structure of Control Commands

Each packet of a control command begins with the
command and ends with the end character (0x0D) as
shown.
Command: ASCII Code of 2 characters
Parameter: ASCII Code (up to 25 characters)
Note: To confirm the status information of the device, send Command + ? + CR to the device from the
host. The device status information is sent to the host.

Structure of Command Codes

Item
Command
Parameter
End Character
When a command is received, the device will respond within 200 ms.
Allow an interval of at least 200 ms between commands when sending a series of commands from
the host. DN-700AVP will not receive commands when the interval is less than 200 ms.
The device can receive control command data during transmission of status command data.
Do not send request commands from the host until the device returns a response.
Wait 1 second after transmitting a Power On command (PWON<CR>) before transmitting the next
command.
Value (Hex value indicated in parentheses)
Indicate a description of the command
Indicate a description of the parameter
CR (0x0D)
COMMAND
PARAMETER
End
Character
CR (0x0D)
5