Download Print this page

Enabling Repeater Mode On Dp750; Dp760 Dect Repeater Association - Grandstream Networks DP760 Quick Installation Manual

Dect repeater
Hide thumbs Also See for DP760:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Enabling Repeater Mode on DP750

1. Access DP750 Web GUI.
2. Navigate to DECT → General Settings and set "Enable Re-
peater Mode" to "Yes".
3. Press Save and Apply, then reboot the unit to apply the new
settings.

DP760 DECT Repeater Association

Using auto/manual association methods, the DP760 repeater
will not be listed on DP750 "DECT Repeater Status" page even
if "Repeater Management Mode" is enabled on DP750.
Auto Association
1. Please put the DP760 DECT Repeater close to DP750, then
power on the DP760.
2. After boot up, the association LED will start blinking to indi-
cate that the repeater is searching for nearby base stations.
Note: If all the LEDs remain on, it indicates that the DP760
DECT Repeater has successfully associated with a DP750
Base and is ready for use.
3. Open subscription on DP750 Base Station using one of fol-
lowing methods:
• Rebooting the Base station.
• Long press on page/subscribe button on the back panel
of DP750 for 7 seconds.
• Access DP750 Web GUI and press subscribe button
4. The DP760 DECT Repeater will automatically pair to DP750.
Upon successful association with the DP750 Base Station all
LEDs will turn ON.
Notes:
•For auto association, the option "Use manually configured
RFPI" under DP760 Web GUI should be disabled (by default
disabled).
•The association may take up to a few minutes. Time will vary
depending on the number of DP760.
~3~
Manual Association
1. Access the Web GUI of your DP760. (Default username and
password are: admin/admin). Refer to [Accessing the Web
UI].
2. Navigate to DECT → General Settings and set "Use Manu-
ally Configured RFPI" to "Yes".
3. On "Manually Configured Base RFPI" field, enter DP750
Base Station RFPI address.
Note: The RFPI Address of your DP750 Base Station is avail-
able under the Web GUI → Status → DECT Base Status → Base
DECT RFPI Address.
4. Click Save and Apply to confirm the new settings.
5. Go to DECT Repeater Status page and click on "Manual-
Lock to xxxxxxxxxx".
6. The DP760 DECT Repeater will automatically pair to DP750.
Upon successful association with the DP750 Base Station all
LEDs will turn ON.
Repeater Management Mode on DP750
The repeater management mode on the DP750 allows to as-
sociate, dissociate and manage discovered and paired re-
peater stations from DP750 web GUI.
Enabling Repeater Management Mode on DP750
.
1. Access DP750 Web GUI. (Default username and password
are: admin/admin).
2. Navigate to DECT → General Settings and set Enable Re-
peater Management to "Yes".
3. Press Save and Apply, then reboot the unit to apply the
new settings.
~4~

Advertisement

loading