LV50-12
LOW VOLTAGE TRANSFORMER
INSTALLATION
Ensure that the unit is installed at least
3.5 metres away from the pool and/or
spa and at a minimum of 500mm above
ground level.
Mount unit using the 2 keyhole slots
provided, at 93mm centres.
CABLE TERMINATION
The LV50-12 transformer has 2 outputs, each
with a pair of terminals. Each cable core should
be terminated as follows:
1. Remove the terminal screw and clamp plate
from the terminal bolt.
2. Place one of the stripped end of the cable on
top of the terminal bolt. Place the clamp plate
on top of the cable end and fasten the
connection in place. As the Transformer
outputs AC power the cable orientation is not
important
For the second cable core, repeat these steps
on the adjacent terminal.
Optional: Once the cable termination is complete,
anchor the cable to the transformer using the cable
management hooks provided. This will help protect the
cable from strain.
Spa Electrics recommends the use of an Electrical
Contractor or Pool Technician for connection of the Pool
Light to the Transformer.
FOR ASSISTANCE PLEASE
CONTACT SPA ELECTRICS
INSTALLATION GUIDE
5mm
ph: +61 3 9793 2299
info@spaelectrics.com.au
www.spaelectrics.com.au
GROUND
500mm (MIN)