OpeMed OT200 User Manual

Compact ceiling hoist
Hide thumbs Also See for OT200:

Advertisement

Quick Links

User Guide:
OT200 Compact
Ceiling Hoist
OpeMed (Europe) Ltd
www.opemed.net
+44 (0)1252 758858
January 2017 | Ref 1120 | OT200 Compact Ceiling Hoist User Manual

Advertisement

Table of Contents
loading

Summary of Contents for OpeMed OT200

  • Page 1 User Guide: OT200 Compact Ceiling Hoist OpeMed (Europe) Ltd www.opemed.net +44 (0)1252 758858 January 2017 | Ref 1120 | OT200 Compact Ceiling Hoist User Manual...
  • Page 2: Table Of Contents

    6.2 Lifting From a Bed ........................13 6.3 Moving the Patient ........................13 6.4 Taking the Patient Out of the OT200 / OT400 ................13 6.4.1 Step 1a Lifting Towards a Bed ................... 13 6.4.2 Lifting Towards a (Wheel) Chair ..................14 6.4.3 Lifting Towards a Toilet .....................
  • Page 3 About OpeMed ........................17 10.1 Contact Details ........................17 EG - Statement of Conformity ..................18 Notes ..........................19 Ref1109 User Manual • • •...
  • Page 4: Ot200 Compact Ceiling Hoist Manual - Introduction

    1 OT200 Compact Ceiling Hoist Manual - Introduction About this Manual The aim of this user manual is to enable carers to operate the OT200 and to instruct them on how to carry out small (preventive) maintenance jobs. This manual deals with the following aspects related to operating the OT200 and OT400: •...
  • Page 5: The Ot200 Ceiling Hoist

    Next to this the hoist can be used for transfers to and from the floor. With this the OT200 also complies to the demands set by the European Standards, ISO 10535 and the GQ-quality mark T-02, cluster UTT.
  • Page 6: Points Of Attention

    OT200 can only be used for this purpose. Any other form of use is not allowed. • It is not allowed to lift more than 200kg (440lbs) with the OT200, unless otherwise stated on the lift. The OT400 can lift 400kg.
  • Page 7: Description

    2 Description The 'OT200' ceiling hoist system consists of a number of components that are discussed in this handbook. In Figure 1 shows the main components. These are described in a separate section. 1" 6" 2" 5" 3" 4" Figure'1 7"...
  • Page 8: Charging And Life-Span Of The Batteries

    The OT200 is also equipped with several other safety systems. Examples are the rewind guard and a slack belt guard. A detailed description of these safety systems can be found in the technical manual.
  • Page 9: Control Indicator Lights On The Hoist (Part 11)

    The hanger bar can be used as a handle for transfers. The OT200 is operated with either a hand-held control or the optional infra-red hand control. This control is used to: •...
  • Page 10: Rail System

    An XY rail system is a system where two rails are put, where a movable rail angles below will be hung from the ceiling. The OT200 will charge at the end of the moving rail and the moving rail needs pushing normally to the end of the fixed rail for charging to commence.
  • Page 11: Hanger Bar

    4 Hanger Bar The OT200 is provided with a hanger bar. The hanger bar is a construction to which the sling (in which the caretaker will take place) can be attached. Several types of hanger bars are available, of which the balanced and the powered hanger bar are the most important types.
  • Page 12: Slings

    • Always refer to the sling user guide. • Always check the weight capacity of the sling and ensure it is not more than the OT200. • 5.1.2 CLIP SLINGS (depends on clip sling used – please refer to sling instructions) Hold on to the strip on the clip with one hand and pull the large hole in the clip over the •...
  • Page 13: Lifting From A Chair

    • caretaker to the final position. Never lift the patient higher than absolutely necessary during a transfer. • Taking the Patient Out of the OT200 / OT400 6.4.1 Step 1a Lifting Towards a Bed • Bring the caretaker into a lying position. Position the patient as good as possible above the bed.
  • Page 14: Lifting Towards A (Wheel) Chair

    Daily/Weekly Maintenance For normal use the OT200 hardly requires maintenance. We do however advice to pay attention to the following points daily in order to prevent or recognize problems in time. Action...
  • Page 15: If The Ot200 Does Not Function

    Service Agreement. If maintained by an authorised person the OT200 hoist should have a sticker tells you when the hoist is due for inspection. For more information about inspections you can always contact OpeMed.
  • Page 16 10 years (100,000 transfers) for maintenance according to specifications. Use of the OT200 in a humid environment or in an environment with aggressive vapours are not "normal circumstances" and can shorten the life of components. If the motor is used in such environment please ask for our Humid Environment Upgrade.
  • Page 17: Warranty Statements

    9 Warranty statements • OpeMed gives a 1 year warranty on the OT200/OT400. OpeMed does not give warranty on any parts that are exposed to wear, like wheels, slings, hoisting belts or batteries. This warranty does not apply to damage or failure of the OT200/OT400 which is caused by •...
  • Page 18: Eg - Statement Of Conformity

    GU9 7UD Hereby declare under our own responsibility that the: The OT200/ OT400 ceiling hoist system and all attached parts to which this declaration relates and which fall within Class I of the European Medical Devices Directive, in accordance with the provisions of the following directive: 11.1.1.1.1.1.1...
  • Page 19: Notes

    12 Notes ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________ ______________________________________________________________________________________________...
  • Page 20 Tel: 01252 758858 Fax: 08701 619681 Email: sales@opemed.net www.opemed.net Clockhouse, Dogflud Way, Farnham, Surrey, GU9 7UD United Kingdom OpeMed manufactures and installs high-quality ceiling hoists and patient handling equipment for the hospital, nursing home and domestic environment • • • User Manual ref1109...

Table of Contents