INSTRUCTION REF: IN172 ISSUE No. DATE 30.10.09 Page 1 of 17 INSTRUCTIONS MODEL: SGWB SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS FAULT DIAGNOSTICS TECHNICAL DATA EXPLODED VIEW / PARTS LIST WARRANTY INFORMATION Customer Information MODEL NUMBER: ______________________ ______________________ SERIAL NUMBER:...
To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. www.parry.co.uk...
Page 3
BS EN 203-2-6:2005 The products have been CE-marked in compliance with the European Gas Directive (90/396/EEC) The Parry Group have designed this range of units for use with the following gases and supply pressures within the following countries of destination. Categories...
All local fire regulations should be observed. It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter. www.parry.co.uk...
The parts protected by the manufacturer or agent, should not be adjusted by the installer. All packing and protective film must be removed from the appliance prior to commissioning. The burner is fitted with a flame failure device and the gas control has an integral piezo spark ignitor. www.parry.co.uk...
Page 6
The appliance must never be left unattended whilst it is on. There are no user serviceable parts. Part sealed by manufacturer must not be adjusted by the user. If any problems with lighting operations are experienced then you must contact your supplier to seek assistance from a competent person. www.parry.co.uk...
Page 7
MAINTENANCE AND CLEANING MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY A REGISTERED FITTER. Parry recommends that this unit is serviced at least every 12 month (this is not covered in the warranty) There are no user serviceable parts in this unit.
Gas supply not available Check gas supply Pilot goes out Poor pilot flame Check / clean or adjust as required Faulty or loose Check / replace as thermocouple necessary Low gas pressure Check gas pressure and adjust where necessary www.parry.co.uk...
Burner Injector INJECT 119 and Butane G30 @ 29mbar 11.2” W.G. Nat Gas G20 @ 20mbar 8” W.G. SGWB Burner Injector INJECT 150 Water temperature rise is 80°C in 60 minutes on G31 and G30 and 75°C in 60 minutes on G20...
3. Undo wing nuts 4. Lift under tray out. 5. Undo the nut that attaches the flexi tube to the injector on the burner 6. Undo 2 x 8mm nuts that attach the burner to the bracket, and remove burner from unit. www.parry.co.uk...
Page 11
11. On completion test for soundness When conversion is complete affix new data label and the appropriate gas label supplied with the conversion kit, detailing type of gas and pressure etc. www.parry.co.uk...
Page 15
(See installation details). Also the miss-use, alteration or unauthorised repairs of the equipment will invalidate the warranty. During the warranty period it is at Parry’s discretion to repair or replace the equipment. Warranty only applies if the equipment has been used in a professional manor following the manufactures instructions and maintenance guide lines.
6 burner cooker. Excessive carbon build up on griddle plates. Over use of lava rock on the chargrills recommended use by Parry 2kg only. Faulty electrics – eg, customers plug socket, plug, wiring, junction box fault, wrong fuse.
Page 17
Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled. Any issues regarding the raised charges should be put in writing to our warranty department for further investigation. Parry Group Ltd Town End Road Draycott Derby...