LUDLUM MODEL 52-1 FAMILY PORTABLE SCINTILLATION PORTAL MONITORS July 2018 Serial Number 210041 and Succeeding Serial Numbers...
Page 2
LUDLUM MODEL 52-1 FAMILY PORTABLE SCINTILLATION PORTAL MONITORS July 2018 Serial Number 210041 and Succeeding Serial Numbers...
Page 4
RETURN OF GOODS TO MANUFACTURER If equipment needs to be returned to Ludlum Measurements, Inc. for repair or calibration, please send to the address below. All shipments should include documentation containing return shipping address, customer name, telephone number, description of service requested, and all other necessary information.
Model 52-1 Family Technical Manual Table of Contents Introduction Specifications User Operation Assembly Instructions Operational Check Personnel Monitoring Description of Controls and Functions Front Panel AC Panel Parameters and Functions RS-232 Port Water Resistant Sleeve Theory of Background Management Safety Considerations...
Page 8
Model 52-1 Family Technical Manual Recycling Parts List Models 52-1, 52-1-1, 52-5, 52-5-1, 52-6 and 52-6-1 Portable Scintillation Porta Monitors Main Board, Drawing 215 x 342-342E Detector Interface Board, Drawing 215 x 347 Power Supply, Drawing 215 x 1072 1 1/8 inch Voltage Divider, Drawing 435 x 435...
The Model 52-5 and 52-6 have the same width dimensions as the Model 52-1. The Model 52-5 is about an inch taller due to the addition of a detector in the base. It has 5 detectors. The Model 52-6 uses 6 detectors, with another additional detector located at the top.
Page 10
Model 52-1 Family Technical Manual Section 1 (FEMA-REP-21). They are designed to be disassembled for ease of transportation and storage, and can be assembled in five minutes or less without tools. All parameters are stored in non-volatile memory, which requires no battery backup. These parameters allow easy operation with minimal setup by minimally trained personnel.
Model 52-1 Family Technical Manual Section 2 Section Specifications 2 line-by-20-character LCD, backlit when operated from Display (Setup): AC power Display (User): five large status LEDs on one side of portal, and detector LEDs to show alarm location 700-1200 V...
Page 12
Outside Dimensions (when set up): For Model 52-1: 211 x 81.3 x 45 cm (83 x 32 x 17.5 in.) (H x W x L) For Model 52-1-1: 211 x 102 x 45 cm (83 x 40 x 17.5 in.) (H x W x L) For Model 52-5: 213 x 81.3 x 48 cm (84 x 32 x 19.3 in.) (H x W x L)
Model 52-1 Family Technical Manual Section 3 Section User Operation his section gives instructions how to set up and use the instrument to monitor a person for radiation. Assembly Instructions This section gives instructions on how to assemble these instruments and get them ready for use.
Page 14
Model 52-1 Family Technical Manual Section 3 To unlatch, lift up the tab and unhook the top cross bar. Set the BASE on the ground with the rectangular tubes pointing up. If optional stabilizer legs are provided, attach to the BASE, front and rear, with screws provided.
(above background level). Ludlum Measurements suggests that this operational check be performed after setup and before use. As long as the system passes the operational check, no calibration or other checks are necessary.
Page 16
Model 52-1 Family Technical Manual Section 3 background setpoints that have been programmed into the unit. If the setpoints have been exceeded, an INSTRUMENT FAILURE alarm is given, and the unit attempts to update background. The instrument will continue to update the background until the alarm condition has been corrected;...
Page 17
Model 52-1 Family Technical Manual Section 3 possibility the alarm was caused by a momentary, coincidental high- background event. Once an alarm has been validated after one (or two) confirming measurements, the subject can be moved away (>10 m) from the monitor, and a secondary scan with a hand-held meter can be performed to identify the location(s) of the contamination or point source.
Model 52-1 Family Technical Manual Section 4 Section Description of Controls and Functions Front Panel Readout: Liquid Crystal Display (LCD), 2-line, 20-character alphanumeric display. Background and alarm data is displayed. increases or changes a parameter Increment (Up Arrow Button: when in setup mode.
Page 19
Model 52-1 Family Technical Manual Section 4 RT Active RB Active *HD Active (* for Models 52-5 and 52-6 only) *FT Active (* for Models 52-5 and 52-6 only) Individual Alarms Sum Alarms # of Samples Bkgnd Update LT Attenuation 0.0%...
Model 52-1 Family Technical Manual Section 4 indicates the batteries are low and must be Low Battery red LED: replaced immediately. AC Panel fuses to limit current from the AC outlet. The Line Fuse: fuses are Littlefuse F-1A or equivalent.
Page 21
This number, in nCi, indicates the size of the source used RDA Size: during the automatic RDA calculation. (The Model 52-1 does not utilize the automatic RDA feature, and the RDA size is set to 500.) This parameter sets the number of Low Background (BKGND) Alarm: counts per 0.2-second interval that the background should not fall below...
(see above). The RS-232 port operates at 9600 baud, 8 data bits, 1 stop bit, no parity (9600,8,N,1). An example print-out from the Model 52-1 RS-232 port after power-on is shown here: LUDLUM MODEL 52-1 PORTAL...
Model 52-1 Family Technical Manual Section 4 An example print-out from the Model 52-5 and the 52-5-1 RS-232 port after a complete count is shown in the following paragraphs. Note that the BKG column is expressed in counts per 0.2-second intervals, while the COUNT column is expressed in terms of sigma above background.
Page 24
Model 52-1 Family Technical Manual Section 4 process is stopped immediately and restarted after the person leaves the portal. One very important consideration for the background measurement process is accounting for the shielding effect of a human body. A human body inside or next to the portal actually lowers the background by several percent.
Page 25
Model 52-1 Family Technical Manual Section 4 order to make a determination on questionable counts. For example, an original count time of two seconds may get extended another four seconds if the count during the original two seconds is not clearly less than the alarm point or clearly more that the alarm point.
Pollution Degree 3 (as defined by IEC 664) Cleaning Instructions and Precautions The Model 52-1, 52-5, and 52-6 series of instruments may be cleaned externally with a damp cloth, using only water as the wetting agent. Do not immerse the instrument in any liquid. Observe the following precautions when cleaning: 1.
Model 52-1 Family Technical Manual Section 5 Electrical Safety Precautions Warning! Please follow the instructions below. If you do not, a potentially hazardous situation could develop, which could result in death or serious personal injury. Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.
Ludlum Measurements, Inc. The Model 52-1, 52-1-1, 52-5, 52-5-1, 52-6, and 52- 6-1 Portable Scintillation Portal Monitors are marked with the following symbols: ALTERNATING CURRENT (AC) (IEC 417, No.
Maintenance Instrument maintenance consists of keeping the instrument clean and periodically checking the calibration. The Model 52-1, 52-5, and 52-6 Series of instruments may be cleaned externally with a damp cloth, using only water as the wetting agent. Do not immerse the instrument in any liquid.
Model 52-1 Family Technical Manual Section 7 Section Checkout Procedure General These models are set for -4 mV sensitivity (pulse height) for their plastic scintillation detectors. Equipment Required 1. Ludlum Model 500 Pulser or equal. 2. High-impedance voltmeter for high-voltage measurements (1000 megohm) 3.
Page 31
Model 52-1 Family Technical Manual Section 7 Connect the cable from the Model 500 Pulser to one of the detector interface boards. Apply power to the board by supplying +12 Vdc and ground on the two-pin connector on the detector interface board.
To this end, Ludlum Measurements, Inc. strives to supply the consumer of its goods with information regarding reuse and recycling of the many different types of materials used in its products. With many different agencies, public and private, involved in this pursuit it becomes evident that a myriad of methods can be used in the process of recycling.
Model 52-1 Family Technical Manual Section 9 Section Parts List Reference Description Part Number Models 52-1, 52-1-1, UNIT Completely Assembled 52-5, 52-5-1, 52-6, Model 52-1 Portal Monitor 48-3172 and 52-6-1 Portable Scintillation Portal UNIT Completely Assembled Monitors Model 52-1-1 Portal Monitor...
Wiring Diagram-Electronics, Drawing 215 x 1044 (2 sheets) Assembly and Setup Model 52-1 & 52-5 Series Packing Instructions, Drawing 215 x 225C Model 52-6 Series Packing Instructions, Drawing 215 x 633B Model 52-1 & 52-5 Series Overall Assembly, Drawing 215 x 225A Model 52-6 Overall Assembly Drawing 215 x 633A Ludlum Measurements, Inc.
Page 41
Model 52-1 Family Technical Manual Section 10 Model 52-1 & 52-5 Series Dimensions, Drawing 215 x 225 Model 52-6 Series Dimensions, Drawing 215 x 633 Car Base Assembly, Drawings 215 x 332 & 332A Car Base Setup, Drawing 215 x 374 & 374B Ludlum Measurements, Inc.