Victaulic Style 441 Installation Instructions

Stainless steel vic-flange adapter 2-6' 60,3-168,3 mm, flange adapter

Advertisement

IMPORTANT
INFORMATION
ALWAYS VERIFY THAT THE GASKET IS SUITABLE FOR THE INTENDED SERVICE. Refer to publication 05.01 for complete information.
PIPE AND MATING
FACE PREPARATION
A
B
Figure 1
Victaulic Company of America
Phone: 1-800-PICK-VIC (1-800-742-5842)
Fax: 610-250-8817
e-mail:pickvic@victaulic.com
I-441
3307 Rev.B
R
The following instructions are a guide for the proper installation of Victaulic Style 441 Stain-
less Steel Vic-Flange Adapters. Proper installation requires pipe that is prepared and grooved
in accordance with the latest Victaulic specifications.
The Style 441 is designed for use with Class 150 raised-face flanges, in accordance with
ANSI B16.5. When a Style 441 is used with a flat-faced flange, the raised projections on
the outside edge and around the mating holes of the flange adapter must be ground flush
to the body. The shaded areas on the sketch to the left identify the projections that need
to be ground flush on both segments.
The Style 441 cannot be used, unless it mounts flush to the mating flange; therefore,
flange washers, or anything else that prevents flush mounting, cannot be used.
The Style 441 must not be used as anchor points for tie rods across non-restrained joints.
The Style 441 must not be used against rubber coated surfaces or with wafer or lug-type
valves, or when the flange adapter does not mount flush with the mating flange.
Because of the outside flange dimension, the Style 441 must not be used 90° to one
another on a standard fitting.
PIPE SIZE
Nominal
Diameter
Out. Dia.
in/
mm
2
50
2 ¹⁄₂
65
3
80
4
100
6
150
®
VICTAULIC
IS AN ISO 9001 CERTIFIED COMPANY
Victaulic Company of Canada
Phone: 416-675-5575
Fax: 416-675-5565
e-mail: viccanada@victaulic.com
8/02
© Copyright 2002, Victaulic

Installation Instructions

Stainless Steel Vic-Flange
• Read and understand all installation instructions before attempting to install any
Victaulic piping products.
• Wear hardhat, safety glasses, and foot protection.
Failure to follow these instructions could result in serious personal injury, property
damage, and/or product damage.
• Depressurize and drain piping systems before attempting to install, remove, or
adjust any Victaulic piping products.
Failure to follow these instructions could result in serious personal injury and/or
property damage.
Sealing Surface
inches/
mm
Actual
in/
"A" Max.
"B" Max.
mm
2.375
2.40
3.40
60,3
61
86
2.875
2.90
3.90
73,0
74
99
3.500
3.50
4.50
88,9
89
114
4.500
4.50
5.50
114,3
114
140
6.625
6.60
7.80
168,3
168
198
Victaulic America Latina
Victaulic Europe
Phone: 610-559-3300
Phone: 32-9-381-1500
Fax: 32-9-380-4438
Fax: 610-559-3608
e-mail: vical@victaulic.com
e-mail: viceuro@victaulic.be
® Registered Trademark of Victaulic
Style 441
®
Adapter
2 - 6" (60,3 - 168,3 mm)
1. The outside surface of the pipe (from
the pipe end to the groove) must be
smooth and free from indentations, pro-
jections, and roll marks to provide a
leak-tight seal for the gasket. All rust,
loose scale, oil, grease, and dirt must be
removed.
2. The gray area of the mating face (Fig-
ure 1) must be free from gouges, undu-
lations, or deformities of any type for
proper sealing.
Victaulic Asia Pacific
Phone: 65-6235-3035
Fax: 65-6235-0535
e-mail: vicap@victaulic.com
Printed in U.S.A
Z000441000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Style 441 and is the answer not in the manual?

Questions and answers

Summary of Contents for Victaulic Style 441

  • Page 1: Installation Instructions

    The Style 441 is designed for use with Class 150 raised-face flanges, in accordance with ANSI B16.5. When a Style 441 is used with a flat-faced flange, the raised projections on the outside edge and around the mating holes of the flange adapter must be ground flush to the body.
  • Page 2 114,3 6.625 ³⁄₄ 3 ¹⁄₂ 168,3 *Bolts are not supplied by Victaulic. When using stainless steel bolts/nuts, consideration should be given to using Figure 2 an anti-seize lubricant on the threads. 5. Closure lugs are provided to ease 6. When the bolt holes are aligned, 4.
  • Page 3 This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.

Table of Contents