SERVICE (CONT.)

Nitro Stout Insert

FIG. 64 NITRO STOUT INSERT
Location:
The Nitrogenator is located inside the cabinet on the
platform assembly. The check valves are components
of the Nitrogenator assembly
Test Procedures:
Inspect & Clean
Remove Nitro nozzle from the dispense station. Locate
the insert inside the nozzle and gently remove insert.
Inspect the inner diameter of all five holes for product
residue. Clean and clear the residue from the holes.
Ensure all holes appear the same diameter size before
installing insert back into a clean Nitro nozzle.
Removal and Replacement:
1. Remove the nitro dispense nozzle.
2. Remove the nitro stout insert from the dispense
nozzle.
3. Check for obstructions and clean if necessary.
4. Reinstall the nitro stout insert into the dispense
nozzle.
5. Reinstall the nitro dispense nozzle.
FIG. 65 NITRO STOUT INSERT