Download Print this page

Advertisement

www.insigniarange.com
Last Modified: 07/10/2014
www.insigniarange.co.uk
INSTALLATION MANUAL
30 Day Technical Support:
01908 226545
GT9005
(NOTE: This service is only available to customers from the day of delivery,
please have your supplier's details and your postcode to hand before calling)
Replacements Parts:
inside of your warranty contact:
www.insigniarange.co.uk/customerService.aspx
Spares/Replacements Parts:
outside of your warranty
contact 0844 800 3069
ATTENTION INSTALLERS:
These instructions must be
WARRANTY REG NO: __________________________
left with the customer
To claim your full 5 year warranty, register your shower within 90 days of delivery at: www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.

Advertisement

loading

Summary of Contents for Insignia GT9005

  • Page 1 INSTALLATION MANUAL 30 Day Technical Support: 01908 226545 GT9005 (NOTE: This service is only available to customers from the day of delivery, please have your supplier’s details and your postcode to hand before calling) Replacements Parts: inside of your warranty contact: www.insigniarange.co.uk/customerService.aspx...
  • Page 2: Table Of Contents

    www.insigniarange.com Last Modified: 07/10/2014 Contents Introduction Electrical Requirements What’s In The Boxes? Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Panel Instructions Help Book Information Parts List...
  • Page 3 Last Modified: 07/10/2014 Thank you for your recent purchase of an Insignia shower. Please read this booklet with great care to ensure you get the best out of your build and have a shower that will last for many years to come! Like everything, in order to obtain a first class product that will serve you well for many years, the effort and correctness put into the assembly will reflect in the quality of your finish.
  • Page 4 www.insigniarange.com Last Modified: 07/10/2014 ASSEMBLY AND SIMPLE PLUMBING THIS PRODUCT BUILD IS RATED SUITABLE FOR DIY PURPOSES PROVIDING THE CUSTOMER IS OF ABOVE AVERAGE SKILLS AND FEELS CONFIDENT IN THEIR ABILTY. ONLY YOU THE CUSTOMER WILL KNOW THIS SO BEFORE ANY ATTEMPT IS MADE TO ASSEMBLY READ THROUGH THE FOLLOWING PAGES IN DETAIL THEN DECIDE.
  • Page 5: Electrical Requirements

    www.insigniarange.com Last Modified: 07/10/2014 YOU WILL NEED TOTAL ELECTRICAL REQUIREMENTS Voltage Rating 220 -240AC Frequency Rating 50HZ Power Rating 3.0KW Other than steam generator Internal Circuit Voltage is Internal Current Rating 0.17A Your electrical contractor should understand ALL legal requirements of connection before undertaking any work or installation. UNDER NO CIRCUMSTANCES UNDERTAKE THIS YOURSELF!!! Note for electrician.
  • Page 6: What's In The Boxes

    www.insigniarange.com Last Modified: 07/10/2014 Whilst the next steps show you how to assemble your shower we want to make sure you have a correct build to ensure you get a trouble free shower. Therefore our advice is to follow the instructions and perform a dry run to ensure you are confident with the build and you understand fully how the unit is assembled. When we use the word “DRY RUN”...
  • Page 7 Note: In some cases you may have more screws than needed, this is done so you have spares! VERY IMPORTANT Have you got everything? If not please contact the Insignia Support Line on 01908 226545. Remember NEVER book your tradesman until everything has arrived, been checked and is present.
  • Page 8 www.insigniarange.com Last Modified: 07/10/2014 Pressure Requirements from your house supply We recommend a bar pressure between 2.5 and 3.4 BAR. If you have a combi boiler system no problem should be experienced. If you have a gravity feed older type installation (hot water tank type usually less than 1 bar) you will almost certainly need a pump.
  • Page 9 www.insigniarange.com Last Modified: 07/10/2014 TO START Make sure you have a clear space, remember when finished and in place you need access to check your build and able to pull the shower out for servicing or should you have the need to replace anything! Take the shower tray and remove all the protective wrapping and fit the waste.
  • Page 10 www.insigniarange.com Last Modified: 07/10/2014 Step 1 Attach the left glass panel to the left column (without control panel) using the ST20 screws. Ensure you run a bead of silicone between the 2 panels and under the bottom of both panels Step 2 Attach the large back panel to the left column using the ST20 screws and again ensuring you run a bead of silicone between the 2 panels and under the large back...
  • Page 11 www.insigniarange.com Last Modified: 07/10/2014 Step 3 The next step is to attach the remaining column (with control panel) to back mirrored panel using the ST20 screws as shown in the picture to the left and again ensure a bead of silicone is placed between the panels and again under the bottom of the control panel.
  • Page 12 www.insigniarange.com Last Modified: 07/10/2014 IMPORTANT If your front fixed glass has 2 black uprights pre-fitted please bypass steps 6 and 7 Please note the wide upright is the outer upright and the cut out sits on the tray side. Step 5 Attach both uprights to your top and bottom rails using the ST35 screws Step 6...
  • Page 13 www.insigniarange.com Last Modified: 07/10/2014 Step 7 With the frame now attached to the back panels, locate and fix the glass panels into place by pushing them as per the arrows in the adjacent image Making sure the edge of the glass with the rubber seal fits into the grove tightly.
  • Page 14 www.insigniarange.com Last Modified: 07/10/2014 Step 8 Place and screw the upright curves into position using the ST20 screws and SW9 washers as indicated by the images.
  • Page 15 www.insigniarange.com Last Modified: 07/10/2014 Step 9 Ensure the back panels are square and you are happy with their final position. Now meet the front frame to the side panels as per the image and screw together using the ST25 screws and SW9 washers. We recommend a bead of silicone is placed under the front frame to add to the rigidity of the shower and the overall sealing.
  • Page 16 www.insigniarange.com Last Modified: 07/10/2014 Step 10 Now align the roof to the glass panel and secure into position using the ST20 screws and repeat this process to fix the glass panels to the tray as indicated by the image.
  • Page 17 www.insigniarange.com Last Modified: 07/10/2014 Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories. We recommend using a screwdriver on the smaller holes.
  • Page 18 www.insigniarange.com Last Modified: 07/10/2014 Monsoon Head Attach the grey hose from your valve to the inner black tube using PTFE tape (please note this only needs to be hand tight. Over tightening will snap/damage the inner black tube) Ozone (o3) Thermostatic Probe Unscrew the chrome pepper pot end and drop Insert the chrome sleeve into the hole situated below...
  • Page 19 www.insigniarange.com Last Modified: 07/10/2014 Wheels Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass. Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a tight fit.
  • Page 20 Connect the hoses to the corresponding inlets on the back of the shower. We suggest using tape thread to ensure a water tight seal. Device output may differ from the image. Please refer to your outer chrome faceplate inside your Insignia shower as a reference point.
  • Page 21 www.insigniarange.com Last Modified: 07/10/2014 Connecting up the water supply The following set up is recommended for the water supply. Left Valve Right Valve Requires 2 x 15mm equal T-Valves Hot Water Cold Water Supply Supply Not Supplied...
  • Page 22: Electric Box Connections

    www.insigniarange.com Last Modified: 07/10/2014 Electric Box Connections Connect the cables below to the corresponding devices on the shower Tray Lights (Requires supplied extension lead) Ozone (o3) Top Light Speaker Earth Radio Aerial Phono (AUX, CD/MP3) RJ11 Phone Connection Thermostatic Probe...
  • Page 23 www.insigniarange.com Last Modified: 07/10/2014 Connection For Tray & Column Lights Using the supplied extension lead, connect the end with the single connection to your tray lights. Next bring the extension lead up the back of the shower and connect one of the plugs to the wire coming from the electric box representing the symbol as shown on the image (essentially bridging the two sets of lights together) Now with the remaining connection, Just leave this as this is not required to be used on...
  • Page 24: Steam Generator Connections

    www.insigniarange.com Last Modified: 07/10/2014 Steam Generator Connections The steam generator has 3 connections. Steam Outlet: Connect the white insulated hose to the white steam pod within your shower. Make sure these are fitted in the correct position as they are only attached for transportation reasons only.
  • Page 25 www.insigniarange.com Last Modified: 07/10/2014 Silicone Seal where shown in red on the inside of the shower TESTING FOR WATER LEAKS LEAVING SHOWER 24 HOURS AFTER BUILD ALLOWING SEALENT TO CURE With all connections tight, the waste and hoses checked, jets fully sealed, your shower still around 18 inches from its designated final resting point and the silicone fully cured (hence leaving for 24 hours minimum) Switch on the overhead shower NOT the massage jets, remember these will fire water out at you and are not suitable for checking leaks as...
  • Page 26: Mk117 Control Panel Instructions

    www.insigniarange.com Last Modified: 07/10/2014 MK117 Control Panel Instructions Button 1 (Light Bulb) Button 7 (Down Arrow) Press 1x For Top Light Channel select down/manual search Press 2x For Column Light Press 3x For All Lights Button 8 (TUN) Press 4x To Switch Off Lights Switch Between manual &...
  • Page 27 www.insigniarange.com Last Modified: 07/10/2014 Need Help? Then simply download the following "Help" advice booklet found at this link below. This contains many useful items such as is your parts warranty registered, advice on cleaning / servicing your shower cabin, fault finding and many more items. This is a MUST to read and not just "HELP". It saves time in nearly all cases, avoiding contact with ourselves as most answers are there for a ready fix! Simply visit: www.insigniarange.co.uk/help.aspx...
  • Page 28: Parts List

    Framework SP164 MK117 Control panel Part Code Part Description Part Code Part Description SP143 Monsoon Shower head SP191 Blister pack GT9005-12 Bottom Rail SP056 Ozone Module (for Steam SP152 Standard shower head GT9005-11 Top rail Showers) GT9005-4 Corner Post (universal)
  • Page 29 All images are registered with ImageTraker Insignia™ is a registered trademark of Maclean International Ltd All images are subject to copyright. Images may not be used in any way shape or form with out written permission from Maclean International Ltd. Images are NOT permitted...