Download Print this page

Dometic RAPS12R-U2 Installation And Operating Instructions page 2

Advertisement

Testing:
Note: The automatic controller incorporates a 30 second 'OFF' delay to prevent the
unit from being affected by voltage dips. When installing the fuse or changing the
pushbutton setting, wait 30 seconds for the unit to reach the correct operating
mode.
1. With the vehicle's engine 'OFF' (not running), set the pushbutton to the
'ON/OFF
WITH ENGINE
should be no voltage. (You may need to wait 30 seconds)
WITH ENGINE
WITH VOLTAGE
2. Start the vehicle's engine, the LED should now illuminate 'Green' and there
should be voltage present at the sockets.
3. Turn the vehicle's engine 'OFF', after 30 seconds the LED should extinguish
and there should be no voltage at the sockets.
4. Press the button in so that it is set to the 'ON/OFF
LED should illuminate 'Red' and there should be voltage present at the
sockets.
5. If the LED does not illuminate and no voltage is present, check the fuse. If
blown, replace the fuse with an equivalent 20 Amp blade fuse. If still no
voltage, check that supply voltage to unit is > 10.0V (see detail below).
Your Fridge Power Kit is now installed and ready for use.
Operation:
 With the switch in the 'ON/OFF
the sockets only when the engine is running. This is for normal operation and
prevents the vehicle's battery from being flattened.
 When the switch is in the 'ON/OFF
receive power all the time while the battery has sufficient power to run
appliances. This allows you to run appliances while the engine is not running.
WARNING – Running appliances in the 'ON/OFF
position could lead to the main vehicle battery being flattened to the
point where the vehicle will not start.
 Two sockets are included for your convenience giving you the option of using
either the 20A or 10A version depending on your needs. If you do use both
sockets simultaneously, the total load must be restricted to 20A max.
Mode / Voltage Settings:
'ON/OFF
WITH ENGINE
'ON/OFF
WITH VOLTAGE
For further information or assistance please call 1800 21 21 21
' mode and test for voltage at the sockets. There
( LED Green )
( LED Red )
WITH ENGINE
WITH VOLTAGE
ON
'
>13.4V
'
>10.6V
- 2 -
WITH VOLTAGE
' position power is supplied to
' position the sockets
WITH VOLTAGE
OFF
<12.8V (After 30 sec delay)
<10.0V (After 30 sec delay)
' mode. The
'

Advertisement