Specifications
Typical for 25°C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Relay specifications
Number
Contact Configuration
Contact Rating
Contact Resistance
Operate Time
Release Time
Vibration
Shock
Dielectric Isolation
Life Expectancy
Power on RESET state
Isolated inputs
Number
Isolation
Resistance
Voltage Range
Input 'High' Level
Input 'Low' Level
Response
Filters
Power consumption
+5 V power
Environmental
Operating temperature range
Storage temperature range
Humidity
Table 1. Relay specifications
16
16 Form C
6A @ 120VAC or 28VDC resistive (see connector ratings below)
100 milliohms max
20 milliseconds
10 milliseconds max
10 to 55 Hz (Dual amplitude 1.5mm)
10 G (11 milliseconds)
500 V (1 minute)
10 million mechanical operations, min
Not energized. NC in contact to Common.
Table 2. Isolated input specifications
16
500V
1.6 k Ohms min
DC:
5 to 28 V (Not TTL compatible)
AC:
5 to 28 V (50 to 1000 Hz)
>5V min (positive or negative input voltage - not TTL compatible)
<2.5V max (positive or negative input voltage)
w/o filter:
20 µS
w/ filter: 5 mS
Time constant:
5 mS (200Hz)
Filter control:
Each input individually programmable
Power-up /reset:
Filters off
Table 3. Power consumption specifications
All relays off
0.7 A typical
All relays on
2.0 A typical
Table 4. Environmental specifications
0 to 70 °C
-40 to 100 °C
0 to 90% non-condensing
18