Download Print this page

emaux FSF350-6W Installation & Operating Instruction page 2

Filter & pump combo

Advertisement

INSTALL/START-UP OF FILTRATION
1 Be sure correct amount of filter media sand is in tank and that all connections have been made and are secure.
)
2 Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve seal,
)
always depress handle before turning.)
3 Prime and start pump. Never tun pump dry! Running pump dry may damage seals,causing leakage and
)
flooding! Fill pump with water before starting motor. (be sure all suction and return lines are open), allowing the
filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at least 1 minute. The initial
back-washing of the filter is recommended to remove any impurities or fine sand particles in the sand media.
4 Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear, about 1/2 to
)
1 minute. Turn pump off and set valve to FILTER position and restart pump.The filter is now operating in the normal
filter mode, filtering dirt particles from the pool water.
5 Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and tighten
)
connections, bolts, nuts, as required.
)
6 Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending upon the
pump and general piping system.)
As the filter removes dirt and impurities from the pool water, the
accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge reading is
1.5 bar, higher than the initial "clean" pressure you noted, it is time to backwash the filter (see BACKWASH under
filter and control valve functions).
NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually
heavy initial dirt load in the water.
Parts of FSF350-6W
Key No. Part No.
Description
1*
88280105 1.5" Top Mount Valve (Black/ White colour)
2*
89280101
1.5" Unionwith Sight Glass and O-Ring (Black/ White colour)
3
06011029 Maximum 40PSI Indication, Stainless Steel Casing
3
01111048 Connector for Pressure Gauge/Stopper
4*
89280102 1.5" Union Set with O-Ring (Black/ White colour)
5
89030204 Hose Adaptor with O-Ring
6
02011026 Sleeve for Hose
7
89032002 FSF350-6W Plastic Hose with Nut
8
01013049 Hose Adaptor with Nut
9
02011104 O-Ring for 1.5" Union
10
88022402 FSF350-6W Pump (SS033)
11
89032001 Pump Assembly Screw
12
01111056 FSP/F350-4-6W Combo Base
13
89010107 Water Drain Set
14
89010106 V350 Lateral Assembly with Center Pipe
15
89010115 V350 Filter tank
16
02011134 O-Ring for Filter Neck
17
01271010 Clamp Lock
18
01181052 Fastener for Filter base
19
89010119 M6*50 Screws With Nut
Notes: 1* 88280105B is 1.5" Top Mount Valve in Black colour
1* 88280105W is 1.5" Top Mount Valve in White colour
2* 89280101B is 1.5" Union with Sight Glass and O-Ring in Black colour
2* 89280101W is 1.5" Union with Sight Glass and O-Ring in White colour
4* 89280102B is 1.5" Union Set with O-Ring in Black colour
4* 89280102W is 1.5" Union Set with O-Ring in White colour
QTY
1
1
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
2
4
2
2-4
Parts of FSF400-6W / FSF450-6W / FSF500-6W / FSF-650-6W
KeyNo. Part No.
Description
1*
88280105 1.5" Top Mount Valve (Black/ White Colour)
2*
89280101
1.5" Union with Sight Glass and O-Ring (Black/ White Colour)
3
01111048 Connector for Pressure Gauge/Stopper
4*
89280102 1.5" Union Set with O-Ring (Black/ White Colour)
5
89032102 1.5" Bulkhaed Fitting with O-Ring
6
06011029 Maximum 40PSI Indication, Stainless Steel Casing
7
89032103 FSF400-6W Plastic Hose with Nut
7
89032201 FSF450-6W Plastic Hose with Nut
7
89032301 FSF500-6W Plastic Hose with Nut
7
89032401 FSF650-6W Plastic Hose with Nut
8
02011104 O-Ring for 1.5" Union
9
88022403 Pump 0.50hp, 220V/50Hz, Single Phase
9
88022404 Pump 0.75hp, 220V/50Hz, Single Phase
9
88021705 Pump 1.00hp, 220V/50Hz, Single Phase
9
88021707 Pump 1.50hp, 220V/50Hz, Single Phase
10
89032001 Pump Assembly Screw
11
01181052 Fastener for Filter Base
12
89010107 Water Drain Set
13
01111053 FSP/F400-6W - FSP/F650-6W Combo Base
14
01172007 Laterals(115mm)
14
01172008 Laterals (126mm)
15
89010116 V400 Lateral Assembly with Center Pipe
15
89010105 V450 Lateral Assembly with Center Pipe
15
89010104 V500 Lateral Assembly with Center Pipe
15
89010103 V650 Lateral Assembly with Center Pipe
16
89010113 V400 Filter tank
16
89010112 V450Filter Tank
16
89010111 V500 Filter tank
16
89010110 V650 Filter tank
17
02011134 O-Ring for Filter Neck
18
01271010 Clamp Lock
19
89010119 M6*50 Screws With Nut
Notes: 1* 88280105B is 1.5" Top Mount Valve in Black Colour
1* 88280105W is 1.5" Top Mount Valve in White Colour
2* 89280101B is 1.5" Union with Sight Glass and O-Ring in Black Colour
2* 89280101W is 1.5" Union with Sight Glass and O-Ring in White Colour
4* 88280102B is 1.5" Union Set wirh O-ring in Black Colour
4* 88280102W is 1.5" Union Set wirh O-ring in White Colour
PRIMING PUMP
Release all air from filter and piping system.
In a flooded suction system (water source higher than pump), pump will prime itself when suction and
discharge valves are opened.
If pump is not in a flooded suction system, unscrew and remove trap cover; fill trap and pump with water.
Clean and inspect Ring; re-install on trap cover.
Replace trap cover on trap; turn clockwise to tighten cover.
NOTICE: Tighten trap cover by hand only .Pump should prime now. Priming time will depend on vertical
length of suction lift and horizontal length of suction piping.
QTY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
8
8
1
1
1
1
1
1
1
1
1
2
2
3-4

Advertisement

loading

This manual is also suitable for: