EXTERNAL PARAORBITAL ELECTRODE
"DENS-GLASSES"
OPERATING MANUAL
TU 9444-002-35266303-2005
RC ART 06.1-03.71-01 RE

Advertisement

Table of Contents
loading

Summary of Contents for RC ART DENS-GLASSES

  • Page 1 LLC “RC ART”, Yekaterinburg, Russia EXTERNAL PARAORBITAL ELECTRODE “DENS-GLASSES” OPERATING MANUAL TU 9444-002-35266303-2005 RC ART 06.1-03.71-01 RE...
  • Page 2: Table Of Contents

    CONTENT Part 1. Specification Part 2. User’s Instructions 1.1. General Description........25 2.1. General Information........33 1.2. Technical Specifications......26 2.2. Terms of Treatment........34 1.3. Package Contents........26 2.3. Course of treatment........34 1.4. Safety Requirements........27 Appendix 1. Recommended application 1.5. Care and Maintenance........30 of the External Paraorbital Electrode 1.6.
  • Page 3: Part 1. Specification

    PART 1. SPECIFICATIONS 1.1. General Description The External Pararobital Electrode (EPE) provides dynamic electric non-invasive neurostimulation of bio- logically active points located in the paraorbital area for a prophylactic and therapeutic effect. Dynamic electric neurostimulation facilitates recovery from visual impairments caused by some eye dis- eases.
  • Page 4: Technical Specifications

    1.2. Specifications Weight……………………………..…….....................0,2 kg Dimensions………...………………..………..............…..190х65х50 mm Cable length………………….…………………................…600 mm 1.3. Package Contents The package includes: Name Quantity External Paraorbital Electrode “DENS-Glasses” Nose Bridge Owner’s manual Package...
  • Page 5: Safety Requirements

    1.4. Safety Requirements Please read the following safety instructions! They are designed to prevent damage to prop- erty and the user! The manual contains important recommendations on proper use and care of the unit. The unit must not be used for treatment of patients with implanted electronic devices (such as car- diac pacemaker) as well as of people with electric sensitivities.
  • Page 6 The unit contains fragile components! Prevent from shock. The unit is not waterproof. Keep away from liquids and moisture. Do not repair the unit yourself. Refer all servicing to the manufacturer. Terms of Transportation The unit should be transported at a temperature between -50 С...
  • Page 7 Terms of storage Store the unit at a temperature from-50 С to +40 С, relative air humidity from 30% to 93% and pressure from 70 to 106 kPa. Operating environment The unit shall be operated at about +10 С to +35 С, relative air humidity from 30% to 93% and pressure from 70 to 106 kPa.
  • Page 8: Care And Maintenance

    1.5. Care and Maintenance Maintenance of the unit should include the following: — visual check of the device; — cleaning of electrodes (use standard disinfection detergents and a soft cloth to clean electrodes); — check of the unit’s readiness for operation when connected to the DENAS or DiaDENS devices. 1.6.
  • Page 9 Observation of regulations governing the device application can considerably increase the lifetime set by the manufacturer. 1.6.3. This product is warranted for the period of 12 months from the original date of purchase. 1.6.4. The consumer is to check the package contents and perform the visual control of the device in the presence of the retailer.
  • Page 10: Manufacturer's Address

    Warranty repairs must be carried out by the Manufacturer or Manufacturer’s Service Centers. 1.7. Manufacturer’s Address Manufacturer: LLC “RC ART”, 620146 Russia, Yekaterinburg, 15 Postovskogo Str. Tel: +7 (343) 267-23-30 Distributor: DENASMS.COM Tel.: +73432015405 http://www.denasms.com/ E-mail: info@denasms.com...
  • Page 11: Part 2. User's Instructions

    PART 2. USER’S INSTRUCTIONS 2.1. General Information The majority of eye diseases are evidence of adaptive dysfunction. The course of an eye disease depends on the patient’s general well-being and presence of concomitant conditions. Dynamic electric neurostimulation (DENS) delivered by the External Paraorbital Electrode is regarded as a constituent part of the prophylactic and therapeutic program in ophthalmopathy treatment.
  • Page 12: Terms Of Treatment

    2.2. Terms of Treatment The application of the External Paraorbital Electrode doesn’t require special conditions. During the session the patient should sit or lie in a comfortable position. 2.3. Procedural information and arrangement of the EPE Prior to the start of treatment, wipe the surface of the electrode with a soft cloth moistened with a disinfect- ing liquid, (e.g.
  • Page 13 Figure 1. External Paraorbital Electrode. Front View...
  • Page 14 Figure 2. External Paraorbital Electrode. Top View Figure 3. Nose Bridges.
  • Page 15 1. Choose and set a nose bridge (see Fig. 3) supplied with the device. 2.Put on and anchor the unit. 3. Connect the unit: — via a holder to the DENAS device; — via an adaptor to the DENAS+ device; —...
  • Page 16 Attention! It is recommended that treatment schemes of chronic eye diseases with the use of the EPE include therapy of segmental and reflexogenic zones. The zones are be selected and treated with the use of inbuilt electrodes of the DENAS and the DiaDENS apparatuses in accordance with general rules described in the Operation Manuals of the appropriate apparatus*.
  • Page 17: Appendix 1. Recommended Application Of The External Paraorbital Electrode In Ophthalmology

    Appendix1 Recommended ways of operating External Paraorbital Electrode in Ophthalmology Session Frequen- Diagnosis Device Regime Notes Duration Power Level Number cy, Hz DENAS Therapy 3-5 minutes Comfortable Repeated courses Visual Asthenopia. 1 session Therapy 3-5 minutes 20 or 77 power level. are recommended Visual fatigue caused a day...
  • Page 18 Session Diagnosis Devise Regime Notes Frequen- Power Duration Number cy, Hz Level DENAS Therapy 3-5 minutes Repeated course rec- ommended in 30-40 Therapy 3-5 minutes 20 or 77 Presbyopy Comfort- 1 session a days. After 2-3 month- (age long- able power day within interval the course Time to be...
  • Page 19 Session Diagnosis Devise Regime Notes Frequen- Duration Power Level Number cy, Hz DENAS Therapy Children under 7 - Accomodation Comfortable 3-minutes; 8-12 years 1 session spasm, Myopia power level. 3-6 re- old – 5 minutes; over a day (short-sighted- For children peated Therapy 20 or 77...
  • Page 20 Session Diagnosis Devise Regime Notes Duration Frequency, Hz Power Level Number DENAS Therapy 3-5 minutes Comfortable 1 session a 5-6 courses Cataract power level. day within with 10-20 days 7-10 days interval DiaDENS Therapy 3-5 minutes 20 or 77...
  • Page 21 Session Diagnosis Devise Regime Action Notes Duration Power Level Number Frequency, Hz Repeated DENAS Therapy 3-5 minutes courses Comfortable 1 session a recommended Glaucoma power level. day within depending DiaDENS Therapy 3-5 minutes 10 days on intraocular pressure dynamics...
  • Page 22 Session Diagnosis Devise Regime Notes Action Fre- Duration Power Level Number quency, Hz Inflammatory DENAS Therapy Comfortable eye diseases 5-10 minutes 1 session power level, Disinfect elec- (acute condition with 60-90 a day minimal for trode before and and exacerba- minutes within 10 children under 7...