COMMERCIAL   3   P HASE   W ATER   H EATING   M ODELS  
 
(NOT   F OR   S PACE   H EATING   A PPLICATIONS)  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
READ   THE   GENERAL   SAFETY   SECTION   BEGINNING   ON   THE   NEXT   PAGE   AND   THEN   THIS  
ENTIRE  MANUAL   BEFORE   INSTALLING   OR   OPERATING  THIS  UNIT.     IF  YOU  DON'T  FOLLOW  
THESE   SAFETY   RULES,   THE   UNIT   MAY   NOT   OPERATE   PROPERLY   AND   COULD   CAUSE,  
SERIOUS   B ODILY   I NJURY,   P ROPERTY   D AMAGE   A ND/OR   D EATH.    
 
READ   YOUR   WARRANTY.     WARRANTY   OF   YOUR   UNIT   WILL   DEPEND   ON   PROPER  
INSTALLATION  AND  OPERATION.    THE  WARRANTY  SHALL  BE  VOID  IF  THE  UNIT  HAS  BEEN  
ALTERED   I N   A NY   W AY   W HATSOEVER.     T HE   M ANUFACTURER   O F   T HIS   H EATER   W ILL   N OT   B E  
LIABLE   FOR   ANY   DAMAGES   DUE   TO   FAILURE   TO   COMPLY   WITH   THE   INSTALLATION   AND  
OPERATING   I NSTRUCTIONS   O UTLINED   O N   T HE   F OLLOWING   P AGES.    
 
THE  INSTALLATION  MUST  CONFORM  TO  ALL  INSTRUCTIONS  IN  THIS  MANUAL  AND  TO  ALL  
LOCAL   A ND   N ATIONAL   C ODES.  
 
IF  YOU  HAVE  ANY  QUESTIONS  OR  REQUIRE  ANY  ASSISTANCE  WITH  THE  INSTALLATION  OR  
THIS   U NIT,   P LEASE   C ALL   O UR   C USTOMER   S ERVICE   D EPARTMENT   A T   T HE   N UMBERS   L ISTED  
BELOW.     P LEASE   H AVE   T HE   I NFORMATION   L ISTED   B ELOW   W HEN   C ALLING   :    
 
SERIAL   # :   _ _________________                   M ODEL   # :   _ ___________               I NSTALLATION   D ATE:   _ ______________  
 
OWNER'S   M ANUAL  
SEISCO   I NTERNATIONAL   L LC.  
241   A irtex   D r.   •   H ouston,   T X     7 7090  
  •   T oll   F ree   ( 888)   2 96-­‐‑ 9 293  
Phone   ( 281)   8 76-­‐‑3300   •   F ax   ( 281)   8 76-­‐‑ 3 338   ●
 
s eisco.com  
 
 

Advertisement

loading
Need help?

Need help?

Do you have a question about the CA-10-208-3P and is the answer not in the manual?

Questions and answers

Summary of Contents for Seisco CA-10-208-3P

  • Page 1 SERIAL   # :   _ _________________                   M ODEL   # :   _ ___________               I NSTALLATION   D ATE:   _ ______________   SEISCO   I NTERNATIONAL   L LC.  ...
  • Page 2 SEISCO   C ommercial   h eaters   a re   d esigned   t o   t ake   i n   c old   o r   p re-­‐‑ h eated   w ater   a nd  ...
  • Page 3: Table Of Contents

      SEISCO   I NTERNATIONAL   L LC.           241   A irtex   D r.   •   H ouston,   T X   7 7090   •   P hone   ( 888)   2 96-­‐‑ 9 293   •   F ax   ( 281)   8 76-­‐‑3338   ●...
  • Page 4: Introduction   T O   T He   S Eisco

          SEISCO   C ONTINUOUS   W ATER   H EATING   S YSTEM       *U.S.   P atents:           # 7,616,873   i ssued   N ovember   1 0,   2 009;  ...
  • Page 5: W Ater   H Eater

      o f   t he   u nique   d esign,   m aterials   a nd   t he   c onstruction   o f   t his   u nit   ( READ   Y OUR   W ARRANTY).     Y our   SEISCO water  ...
  • Page 6: Dos   A Nd   D On'ts

    DOs   &   D ON’Ts   Your   S EISCO is   d esigned   f or   e asy   m aintenance.   A VOID   I NSTALLATION     ®   IN   C ONFINED   S PACES.   A llow   a t   l east   1 8   i nches   o f   w orking   s pace   a bove    ...
  • Page 7: Installation   G Uide

    INSTALLATION   G UIDE         NOTE:   T HIS   W ATER   H EATER   M UST   B E   I NSTALLED   T O   M EET   T HE   C URRENT   N ATIONAL   E LECTRIC   CODE,  ...
  • Page 8                       Plumbing   c onnections   w ith   T &P     Plumbing   c onnections   w ithout   T &P           T EMPERATURE   &   P RESSURE   R ELIEF   V ALVES        ...
  • Page 9: Electrical   I Nstallation

    ELECTRICAL   I NSTALLATION   G UIDE     CONNECTION   T O   P OWER   S UPPLY     WARNING:   Y OUR   S EISCO   M UST   B E   I NSTALLED   A ND   S ERVICED   B Y   Q UALIFIED   P ERSONNEL.   D AMAGE   T O   ®...
  • Page 10 SEISCO   M OUNTING   C LEARANCES   Top Clearance: For removal of heating elements and to provide room for plumbing connections, a minimum of 12 inches is required. Side Clearance: Allow an overall minimum horizontal space for the heater of 24 inches for removal of protective cover screws and access to electrical wires entering the heater from the side.
  • Page 11 START-­‐‑ U P   F UNCTIONAL   C HECKS       PRE-­‐‑ P OWER   C HECK   •   After   a ll   e lectrical   c onnections   h ave   b een   m ade;   e very   e ffort   s hould   b e   m ade   to  ...
  • Page 12     SEISCO   P ROVIDES   O N-­‐‑ B OARD   S ELF-­‐‑ D IAGNOSTICS     However,   i n   t he   e vent   t hat   t he   L ED   l ight   c ontinues   t o   f lash   a   r ed   s equence   a fter   p ower-­‐‑ o n,  ...
  • Page 13   t o   m atch   t he   f low   r ating   a nd   t emperature   r ise   s pecifications   o f   t he   h eater.   T he   Seisco   w ater   h eater   s pecifications   c an   b e   f ound   i n   t he   P roduct   D escription   a nd  ...
  • Page 14   s ervice   p rovider   p lease   c ontact   y our   p lace   o f   p urchase,   v isit   t he   S eisco   w ebsite   ( www.seisco.com),  ...
  • Page 15: Troubleshooting   G Uide

      r egular   b usiness   h ours   f or   a vailable   p arts,   d iagnostics   a nd   r epair   i nformation   o r   e mail   s ervice@seisco.com.  ...
  • Page 16: Product   S Pecifications

          PRODUCT   S PECIFICATIONS             PHYSICAL   D ESCRIPTION                 Model       Height   Width   Depth   Pipe   S ize   Shipping  ...
  • Page 17       FOUR   C HAMBER   M ODELS     INTERNAL   W ORKINGS   A ND   P ARTS   I DENTIFICATION           Outlet   Inlet     Level   D etect   Heating  ...
  • Page 18       TWO   C HAMBER   M ODELS         INTERNAL   W ORKINGS   A ND   P ARTS   I DENTIFICATION             Outlet   Inlet    ...
  • Page 19     Your   SEISCO   can   be   serviced   by   most   major   brand   authorized   appliance   repair   or   heating   and     plumbing   centers   in   your   area.   If   your   preferred   service   center   does   not   already   have   service  ...
  • Page 20     SEISCO   I NTERNATIONAL   L LC.   241   A irtex   D r.   •   H ouston,   T X     7 7090     •   T oll   F ree   ( 888)   2 96-­‐‑ 9 293  ...