Seisco POU24-120 Installation Manual And Owner's Manual

Electric tankless point of use water heater

Advertisement

  E LECTRIC   T ANKLESS   P OINT   O F   U SE   W ATER   H EATER
INSTALLATION   G UIDE   &   O WNERS   M ANUAL
This manual is provided as a guide to installation. All installations must comply with
any and all local and national electrical and plumbing codes. Warranty of this heater
will depend on proper installation and operation. The manufacturer will not be liable if
the heater has been modified in any way or the installation and operating instructions
outlined in the following pages have not been followed in their entirety.
our SEISCO® water heater can be serviced by most heating, plumbing or HVAC
Y
repair centers in your area. If your preferred service center does not already have
SEISCO® service information, SEISCO International Limited will promptly provide the
necessary information to the service center on request. For information regarding
service companies in your area, please contact your original installer or SEISCO
International Limited.
Seisco International Limited
Customer Service Department
241 W. Airtex
Houston, TX 77090
888-296-9293
International 281-876-3300
email:service@seisco.com
If you have any questions regarding the installation or performance of this heater,
please call our customer service department and provide the information listed below:
Model:___________
Serial Number: ______________________ Install Date: ________
ANY RETURNS AUTHORIZED BY SEISCO MUST HAVE A VALID RETURN MERCHANDISE AUTHORIZATION
NUMBER CLEARLY VISIBLE ON THE PACKAGE. ALL OTHER SHIPMENTS WILL BE REFUSED. BE SURE TO
RETURN THE PACKAGE TO THE ADDRESS LISTED ON THE AUTHORIZATION
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POU24-120 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seisco POU24-120

  • Page 1 SEISCO® water heater can be serviced by most heating, plumbing or HVAC repair centers in your area. If your preferred service center does not already have SEISCO®...
  • Page 2 A.   M OUNTING   T HE   U NIT The   u nit   m ust   b e   m ounted   l evel   o n   t he   w all   ( or   w ith   t he   w ater   fi Dngs   u p   t o   3 °   higher  ...
  • Page 3 B.   P LUMBING   H OOK-­‐UP 1. The   u nit   i s   s upplied   w ith   3 /4”   N PT   fi Dngs   m olded   i nto   t he   h eaIng   c hamber.     D O   N OT   USE  ...
  • Page 4 D.   E LECTRICAL   H OOK-­‐UP Wire   e ntry   i nto   t he   u nit   s hould   b e   m ade   through   t he   k nockout   i n   t he   b o\om   o f   t he   cover.
  • Page 5 Temp Rise@GPM Temp Rise@GPM Temp Rise@GPM Maximum Maximum Model Model Voltage Voltage AMPS AMPS Length Length 0.75 POU24-120 13" POU30-120 13" POU35-120 29.2 13" 208V Models* 208V Models* 208V Models* 208V Models* 208V Models* 208V Models* 208V Models* 208V Models*...
  • Page 6   h eater,   a nd   m ust   b e   p iped   b y   a   m inimum   1 "   p ipe   t o   a n   a dequate   d rain; If   the   SEISCO   heater   or   any   of  its  components   warranted  herein  are   used   other   than  as   a   part   of   the   complete   and  ...
  • Page 7 Point of Use Models are designed to be connected to the COLD water line near the desired point of use needing hot water. Unit must be properly sized to provide sufficient hot water for the desired number of fixtures to be served. Contact your dealer or SEISCO sales representative for assistance in sizing for your application.
  • Page 8 Check   t he   c ircuit   b oard   L ED   f or   a ny   d iagnosIc   c odes.     V isit   h \p://seisco.com   o r   c ontact  ...