P/N 7101494 REV. A A.Y.
PIR sensing device and general
• Quad (four element) PYRO sensor and hard
lens for outstanding detection performance
and elimination of false alarms.
• VLSI based electronics with
movement speed spectrum
analysis.
• User-friendly installation with
swivel bracket.
• BI directional temperature
compensation.
• Environmental immunity.
• The ACTIV8 MONO/COLOUR
provides pet immunity up to 25Kg.
Pet active bellow 1m.
• Height installation calibrations free from 1.8m
to 2.4m.
• Wide range operating voltage.
High reliability and trouble free operation
REMOVAL OF FRONT COVER
Unscrew the holding
screw and open base
DETECTOR INSTALLATION
TERMINAL BLOCK CONNECTIONS
Terminals 1 & 2 - Marked " TAMP "
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will
be sent to the control unit.
Terminals 3 & 4 - Marked " AUD "& "GND"
This is the audio signal output. These two
terminals should be connected to an audio input.
Terminals 4 & 5 - Marked " GND "& "VID"
This is the video signal output. These two
terminals should be connected to video input.
Video sensing device
∗ High sensitivity and high resolution board
camera.
∗ Camera protections cover - optional.
∗ Electronic shutter control.
Audio sensing device
∗ Omnidirectional response.
∗ High sensitivity.
DETECTION PATTERN
15m
.
1. To remove the front cover, unscrew the holding
screw and gently raise the front cover.
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
3. Break out the desired holes for proper installing.
4. Put wire through the bracket and holes "A".
5. Mount the detector base to the wall or on the
ceiling with a suitable bracket. (Install bracket).
6. Reinstall the PC board by fully tightening the
holding screw. Connect wire to terminal block.
7. Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
Terminals 6,7 & 8 - Marked " NO,COM &NC "
These are the output relay contacts of the
detector. Connect to a normally closed or normally
opened zone in the control panel.
Terminal 9 - Marked " + " (+12V)
Connect to a positive Voltage output of 8.2 -16Vdc
source (usually from the alarm control unit)
Terminal 10 - Marked " - " (gnd)
Connect to the negative Voltage output or ground
of the control panel.
PRODUCT FEATURES
The Activ8 MONO/COLOUR provides
immunity up to 25Kg. For better immunity
avoid installation in areas where pets can
reach upwards.
TYPICAL INSTALLATION
SELECT MOUNTING LOCATION
Choose a location most likely to intercept an
intruder. (Our recommendation is a corner
installation). See detection pattern. The quad-
element high quality sensor detects motion
crossing the beam; it is slightly less sensitive
detecting motion toward the detector.
The ACTIV8 MONO/COLOUR performs best
when provided with a constant and stable
environment.
AVOID THE FOLLOWING LOCATIONS
• Facing direct sunlight.
• Facing areas that may change temperature
rapidly.
• Areas where there are air ducts or
substantial airflows.
The ACTIV8 MONO/COLOUR performs better
when provided with a constant and stable
environment.
MOUNTING DETECTOR BASE
KNOCKOUT HOLES
A
B
CIRCUIT LAYOUT
A
A. Wire access
holes
B. For bracket
mounting

Advertisement

loading

Summary of Contents for Honeywell Activ8 COLOUR

  • Page 1: Motion Detector

    Activ8 MONO MONO Video sensing device ∗ High sensitivity and high resolution board camera. ∗ Camera protections cover - optional. Activ8 COLOUR Activ8 COLOUR Activ8 COLOUR Activ8 COLOUR ∗ Electronic shutter control. Audio sensing device QUAD ELEMENT PIR ∗ Omnidirectional response.
  • Page 2 SETTING UP THE DETECTOR TIME ADJUSTMENT PIR SENSITIVITY ADJUSTMENT PET IMMUNITY SETTING SWITCH 5 OF DIP-5 SWITCH FOR SETTINGS SWITCH 4 OF DIP-5 SWITCH FOR SETTINGS SWITCH 1 & 2 OF DIP-5 SWITCH FOR “PET” 15kg – 25kg “PULSE” - provides sensitivity control of the PIR SETTINGS “TIME”...

This manual is also suitable for:

Activ8 mono