PCE Americas PCE-RT 10 Manual

Surface roughness tester

Advertisement

Quick Links

MANUAL
SURFACE ROUGHNESS TESTER
PCE-RT 10
This Surface Roughness Tester is small in
size, light in weight, easy to carry. Although
complex and advanced, it is convenient to
use and operate. Its ruggedness will allow
many years of use if proper operating
techniques are followed. Please read the
following instructions carefully and always
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCE-RT 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for PCE Americas PCE-RT 10

  • Page 1 PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13 Suite 8 Southpoint Business Park Jupiter Ensign way FL-33458 Hampshire / Southampton United Kingdom, SO31 4RF From outside US: +1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0...
  • Page 2 TABLE OF CONTENTS 1. FEATURES............1 2. SPECIFICATIONS..........2 3. FRONT PANEL DESCRIPTIONS AND NAMES OF EACH PARTS.......4 4. MEASURING PROCEDURE......5 5. HOW TO SET THE EVALUATION LENGTH..7 6. HOW TO CALIBRATE THE TESTER....8 7.COMMUNICATE WITH PC........8 8.GENERAL MAINTENANCE......8 9.REFERENCES..........
  • Page 3 1. FEATURES Itself off about 5 minutes after the last key This instrument is compatible with four standards operation. of ISO, DIN, ANSI and JIS and is widely used in *Metric /Imperial Conversion production site to measure surface roughness of 2.
  • Page 4 3. FRONT PANEL DESCRIPTIONS AND NAMES Evaluation length: 1~2 cut off optional OF EACH PARTS Power battery: 4x1.5vAA/UM 3 Operating conditions: Temp. 0~40℃ Humidity <80% 3-11 Size:128×80×30mm Weight: about 280 g Standard Accessories: Carrying case Main unit 3-10 Standard sensor Standard sample plate 0.25mm Operation manual...
  • Page 5 D. To check if the cutoff length selected is right. if not, Calibration depress the key to select. For the recommended CUTOFF Measurement cut-off length, please see the table in 10.7on page 13. Position pointer E. To check if the measurement unit selected is Parameters right.
  • Page 6 the key CAL. Then change the evaluationlength to the desired length among 1~2Lby the key . To save Um/Uin Ra/Rz or quit, just press any key except the key Ra/Rz Um/Uin 6.HOW TO CALIBRATE THE TESTER 0.25mm 6.1 To enter the calibration state, just depressing the , The calibration state is marked by CAL “...
  • Page 7 by scratches. 9. REFERENCES 9.1 Central line This tester adopts minimum central line of Least Square Algorithm. 9.2 Definition of roughness parameter 9.2.1 Ra arithmetical mean deviation of profile Arithmetic value of mean deviation of profile within sampling length. 9.3 Code Standard Name ISO 4287 International Standard DIN 4768(2010-07-00)
  • Page 8 batteries. 10.3 Install the batteries (4x1.5v AA/UM 3) correctly into the case. Cutoff length recommended Please see the table on page 13. Cutoff length (μm) (μm) (mm) >20~40 >5~10 >2.5~5 >10~20 >1.25~2.5 >6.3~10 >0.63~1.25 >3.2~6.3 >0.32~0.63 >1.6~3.2 >0.25~0.32 >1.25~1.6 >1.0~1.25 >0.20~0.25 >0.16~0.20 >0.8~1.0...

Table of Contents