CAUTION!
electronic programmable timer
TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT
*
OWNER'S
THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS
OFF BEFORE WIRING.
MANUAL
Congratulations on your
purchase of a UPM timer.
This timer must NOT be used on loads exceeding 1800W.
Please take the time to
read and understand this
Handle installation with caution to prevent any risk of electrical shock
manual so you can begin
that could cause serious injury or death. If you are not sure about any
to enjoy the security and
energy saving benefits this
part of the given instructions, consult a qualified electrician.
product has to offer.
All wiring must comply with applicable codes and regulations.
One-Touch
Countdown
FEATURES
20 ON programs /
20 OFF programs
Countdown timer -
"One-Touch Countdown"
3 random functions
12/24 hour clock
15A, 1800W (resistive)
single pole or three-way
THREE-WAY INSTALLATION DIAGRAM
GETTING STARTED
button placements
INSTALLING THE TIMER IN PLACE OF LOAD SWITCH
1
SET - activates set functions
Power Source
2
CD - activates countdown timer
8
3
HOT SWITCH
ETW353
R - reset
Blue
4
RND - activates random functions
White
2
LOAD
1
Black
COMMON
5
- scrolls through selections
Green
Red
3
5
6
ON/OFF - manual on/off control
JUMPER
3 Way
6
4
7
Main On/Main Off
7
8
One-Touch Countdown Button
CLOSE UP VIEW OF THE HOT SWITCH
COMMON TERMINAL
display
HOT WIRE
Weekday indicators
MO TU WE TH FR SA SU
X
Disabled program
HOT WIRE
icon
AM/PM
Random function indicator
ON/OFF indicator
L -
RND
SET
CLOCK CD
PROGONOFF
Set function indicator
FIGURE 3
Clock function
Countdown function indicator
JUMPER WIRE
indicator
SINGLE POLE INSTALLATION
SINGLE POLE INSTALLATION DIAGRAM
1
Disconnect the power supply at the circuit breaker or fuse before
proceeding with the installation.
2
Remove existing switch and identify the wires in the wall box.
3
Using the supplied wire nuts, securely fasten the wires on the timer
to the wires in the wall box according to diagram FIGURE 1.
ETW353
Connect the black (hot) wire on the timer to the hot wire in the
Blue
wall box.
White
Connect the blue (hot) wire on the timer to the hot wire in the
wall box coming from the light fixture.
LOAD
Black
Connect the white (neutral) wire on the timer to the neutral
wires in the wall box.
Green
Red
Terminate the red (three-way) wire on the timer with a wire nut.
(For a single pole installation, the red wire is not needed).
For proper grounding, connect the green (ground) wire on
Screw
the timer to the ground "screw" found inside the wall box.
Power Source
4
Mount timer into the wall box carefully.
5
Restore power supply at the circuit breaker or fuse.
FIGURE 1
GETTING STARTED
setting the clock
PROGRAM SETTINGS
MO TU WE TH FR SA SU
MO
1
1
Go to
CLOCK
using
Program select with
MO TU WE TH FR SA SU
PROGON
1
CLOCK
ON
2
Press SET
PROGON
2
Press SET
Day select with
3
3
2 4 6 8
Day select with
* Individual days / weekly selections
3 5 7
MO
1
4
Press SET
4
Press SET
CLOCK
ON
5
3 5 7 9
Hour select with
5
Hour select with
6
Programs are arranged in a circular pattern
2
Press SET
with the clock and countdown functions:
7
6
Minute select with
Press SET
Press SET
4
CLOCK
Program 1–20
8
7
Press SET
Minute select with
Minute select with
6
Each program has an "ON" and "OFF" setting. Both must be set for operation.
8
*
8
Press SET
Example: PROG 1 has an "ON" and "OFF"
10
disable program/master disable
9
Second select with
For single disable select PROGRAM with
1
10
Press SET
For master disable go to
CLOCK
using
2
X
Press SET
2
4
To toggle between 12/24 hour format, press RND during clock setting
3
Press ON/OFF to disable ( X )
To activate/deactivate Daylight Saving Time (DST) function, press and hold
CLOCK
4
Press SET 3 times to exit (single disable)
both
and
together for 3 seconds in
mode; solid
for DST
OR press SET 4 times to exit (master)
memory backup
Repeat steps
1
to
4
to undo disable ( X )
This UPM wall switch timer comes with built-in memory backup protection. In the
For a single program disable, both the "ON" and "OFF" setting must be disabled
*
event of a power outage, all program and clock settings will remain in memory.
individually
THREE-WAY INSTALLATION
THREE-WAY INSTALLATION
There are two switches in a three-way circuit. The switch directly
ADDING A JUMPER WIRE TO THE LOAD SWITCH
connected to the circuit breaker is the HOT switch. The second switch is
the LOAD switch. Ensure you know which switch you are replacing.
Disconnect the power supply at the circuit breaker or fuse before
*
proceeding with the installation.
INSTALLING THE TIMER IN PLACE OF HOT SWITCH
5
Take out the LOAD switch and identify the common terminal.
1
Disconnect the power supply at the circuit breaker or fuse before
6
Connect the jumper wire to the LOAD switch according to diagram
proceeding with the installation.
FIGURE 2.
2
Remove existing switch and identify the wires in the wall box.
Connect the jumper wire from the common terminal to the
3
Using the supplied wire nuts, securely fasten the wires on the timer
hot terminal of the LOAD switch.
to the wires in the wall box according to diagram FIGURE 2.
7
Mount LOAD switch back into the wall box carefully.
Connect the black (hot) wire on the timer to the hot wire in the
8
wall box.
Restore power supply at the circuit breaker or fuse.
Connect the blue (hot) wire on the timer to the load wire in
the wall box coming from the LOAD switch.
Connect the white (neutral) wire on the timer to the neutral
3-Way
Power Source
wires in the wall box.
Connect the red (three-way) wire on the timer to the three-way
wire in the wall box coming from the LOAD switch.
For proper grounding, connect the green (ground) wire on
Timer
Load Switch
the timer to the ground "screw" found inside the wall box.
4
Mount timer into the wall box carefully.
COUNTDOWN TIMER
RANDOM FUNCTION
short/long random
The to-the-second countdown feature of this timer starts from the ON or OFF
Short random from
CLOCK
1
position and counts down to zero when activated.
OR Long random from
CD
1
2
Press RND
Select CD mode using
CD
PROGON
RND
3
Flashing
for short random
2
Press SET
Flashing
L RND
-
for long random
3
Start ON or OFF select with
* Short random 1-2 hours, long random 2-3 hours
4
Press SET
programmable random
CD
5
Hour select with
1
CD
PROGON
6
1
Press SET
3 5 7 9
Select program 20 with
2
7
Minute select with
4
2
Press RND
8
6
Press SET
3
Set program 20 to desired random time
9
8
Second select with
1
4
10
Solid
RND
for programmable random
10
Press SET
3
* Programmable random only works with program 20; 1-2 hours
Press CD or the One-Touch Countdown Button to start the countdown timer.
Stop countdown timer with CD (or One-Touch Countdown Button) or ON/OFF.
Deactivate random function with RND or ON/OFF
THREE-WAY INSTALLATION
THREE-WAY INSTALLATION DIAGRAM
INSTALLING THE TIMER IN PLACE OF HOT SWITCH
INSTALLING THE TIMER IN PLACE OF LOAD SWITCH
Power Source
1
Disconnect the power supply at the circuit breaker or fuse before
LOAD SWITCH
proceeding with the installation.
ETW353
2
Remove existing switch and identify the wires in the wall box.
Black
3
White
Using the supplied wire nuts, securely fasten the wires on the timer
LOAD
COMMON
Blue
to the wires in the wall box according to diagram FIGURE 3.
Green
Connect the blue (hot) wire on the timer to the hot wire in the
Red
JUMPER
wall box coming from the lighting fixture.
3 Way
Connect the black (hot) wire on the timer to the hot wire in
the wall box coming from the HOT switch.
Connect the white (neutral) wire on the timer to the neutral
CLOSE UP VIEW OF THE LOAD SWITCH
wires in the wall box.
COMMON TERMINAL
Connect the red (three-way) wire on the timer to the three-way
HOT WIRE
wire in the wall box coming from the HOT switch.
HOT WIRE
For proper grounding, connect the green (ground) wire on
the timer to the ground "screw" found inside the wall box.
4
Mount timer into the wall box carefully.
FIGURE 2
JUMPER WIRE
TROUBLESHOOTING
LIMITED FOUR-YEAR WARRANTY
3
problem
solution
UPM warrants this product, excluding battery, to be free from defects in the materials or workmanship, under normal use and
service, for a period of four
(4)
years from the date of purchase by the consumer.
If, at any time during the warranty period, the product is defective or malfunctions, UPM shall repair or replace it (at UPM's
LCD display seems "frozen".
Press reset button to reset timer.
discretion) within a reasonable period of time.
1
Buttons won't respond.
If the product is defective,
(i)
return it, with a dated proof of purchase, to the retailer from which you purchased it, or
(ii)
package it carefully, along with a dated proof of purchase and a short description of the malfunction, and mail it, postage
Programmed ON/OFF times
Ensure that the program disable
prepaid, to the following address:
2
don't execute.
feature is not enabled.
UPM Marketing Inc.
Return Goods
Unit 10B 250 Shields Court
Programmed ON/OFF times
Ensure that the random function
Markham, Ontario
don't execute at specified times.
is not enabled.
L3R 9W7
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by UPM that the defect or
Three-way switch is not working
Disconnect power supply at the
malfunction was caused by damage which occurred while the product was in the possession of the consumer.
4
properly.
circuit breaker or fuse. Check
UPM's sole responsibility shall be to repair or replace the product within the terms stated above. UPM SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTL Y
installation for proper wiring.
3
OR INDIRECTLY , FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not
1
apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY UPM MAKES ON THIS PRODUCT . THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
TECHNICAL SPECIFICATIONS
HEREBY LIMITED TO THE FOUR YEAR DURATION OF THIS WARRANTY . Some states do not allow limitations on how long an
2
implied warranty lasts, so the above limitation may not apply to you.
Program: 20 programs
This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
Ratings:
120V AC, 15A
If you have any questions concerning this warranty, please write to:
Max Load: 1800W resistive, 600W tungsten; single pole or three-way
Min switching time: 1 minute
UPM Marketing Inc.
Customer Service Department
Unit 10B 250 Shields Court
Markham, Ontario
L3R 9W7
Or call 1-888-GO-TO-UPM (1-888-468-6876), Monday to Friday, from 9:00am to 5:00pm eastern.
THREE-WAY INSTALLATION
ADDING A JUMPER WIRE TO THE HOT SWITCH
Disconnect the power supply at the circuit breaker or fuse before
*
proceeding with the installation.
5
Take out the HOT switch and identify the common terminal.
6
Connect the jumper wire to the HOT switch according to diagram
FIGURE 3.
Connect the jumper wire from the common terminal to the
hot terminal of the HOT switch.
7
Mount HOT switch back into the wall box carefully.
8
Restore power supply at the circuit breaker or fuse.
3-Way
Power Source
Hot Switch
Timer

Advertisement

loading

Summary of Contents for UPM ETW353

  • Page 1 Press SET programmable random CLOCK Program 1–20 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by UPM that the defect or ON/OFF - manual on/off control Press SET Minute select with...
  • Page 2 DESCENDIENTE función aleatoria corta / larga problema solución UPM garantiza que este producto, excluyendo la batería, está libre de defectos tanto en materiales como mano de obra, bajo uso y Vaya a CLOCK usando MO TU WE TH FR SA SU servicio normal, por un período de cuatro (4) años a partir de la fecha de compra por el consumidor.