INSTRUCTION MANUAL
Magnetic Displacement Sensor
High Accuracy Eddy Current Type Displacement Sensor
GP-A Series
CME-GPA(01) No.0031-88V
Thank you very much for using our products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI
or IEC etc., for personnel protection applicable in each region
WARNING
or country.
1
SPECIFICATIONS
For 1mm sensing
For 2mm sensing
For 5mm sensing
Type
Non-threaded
Non-threaded
Threaded type
Threaded type
type sensor head
type sensor head
sensor head
sensor head
Item
Set model No. (Note 1)
GP-A5S(I)
GP-A8S(I)
GP-A10M(I)
GP-A12ML(I)
Sensing range
0 to 1mm
0 to 2mm
0 to 5mm
Iron sheet
Iron sheet
Standard sensing object
Iron sheet 12 12 t1mm
8 8 t1mm
30 30 t1mm
Supply voltage
24V DC 10% Ripple P-P 10% or less
Current consumption
150mA or less
Analog output
Analog voltage
Analog current
Analog voltage output
Output voltage: 0 to 5V
Output current: 4 to 20mA
Analog current output
Output impedance: 100
approx.
Load resistance: 0 to 350
Response frequency
1.6kHz (-3dB)
Resolution
0.04% F.S.
Linearity
Within
0.5% F.S.
NPN open-collector transistor
Maximum sink current: 100mA
Alarm output
Applied voltage: 30V DC or less (between alarm output and 0V)
Residual voltage: 1.6V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
Turns ON when the sensor head connection is improper or the sensor
Output operation
head cable is disconnected
Short-circuit protection
Input condition: Non-voltage contact or NPN open-collector transistor input
Signal condition: Low ... 0 to 1V (duration 30ms or more)
External zero-adjustment
High ... 5 to 30V, or open
input
Operation: Low ... External zero-adjustment setting
High ... External zero-adjustment ineffective
Zero-adjustment setting
Push button setting / External input setting
method
Power indicator
Green LED (lights up when the power is ON)
Over indicator
Orange LED (lights up when sensing range is exceeded)
Alarm indicator
Yellow LED (lights up when alarm output is ON)
Shift adjustment (by push-buttons)
Adjustment functions
Span adjustment (by 14-turn adjuster)
0.6 m/
1.5 m/
Temperature
Sensor head
0.5 m/
1 m/
for GP-A8SI and
2.5 m/
for
characteristics
GP-A10MI
GP-A12MLI
(Note 2)
Amplifier
0.4 m/
0.8 m/
2.0 m/
Sensor head
IP67 (IEC), IP67g (JEM)
Protection
Amplifier
Sensor head
-10 to +55 , Storage: -20 to +70
Ambient
temperature
Amplifier
0 to +50
(No dew condensation), Storage: 0 to +50
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Enclosure:
Enclosure:
Stainless steel
Enclosure: Stainless steel
Brass
Sensor head
(SUS303)
(SUS303)
(Nickel plated)
Material
Sensing part:
Sensing part: ABS
Sensing part:
Polyalylate
Nylon
Amplifier
Enclosure: ABS
Cable (Note 3) Sensor head
Connector attached high frequency coaxial cable, 3m long
Cable length
Amplifier
Up to total 100m with 0.3mm
2
, or more, cable
(Note 4)
50g approx.
45g approx.
Sensor head
40g approx.
(Note 5)
(Note 5)
Weight
Amplifier
170g approx.
Nut: 2 pcs.
Accessories
Adjusting screwdriver: 1 pc.
Toothed lock washer: 1 pc.
Adjusting screwdriver: 1 pc.
Notes: 1)
Set model Nos. having the suffix 'I' are different frequency type.
2)
These values are for a range which is 20 to 60% of the maximum sensing distance.
3)
The length of the sensor head cable cannot be changed.
4)
The given weight of the threaded type sensor head is the value including the nuts and the
toothed lock washer.
5)
Take care that the output voltage is reduced due to the resistance of the wiring cable.
2
CAUTIONS
Make sure that the sensor head and the amplifier which have the same
production serial number (7 digit) are used in combination. Since adjust-
ment is done before shipment, if items with different production serial
numbers are combined, the sensing characteristics will deteriorate even if
they have the same model Nos.
<Sensor head>
(Example)
Serial number: 4A6N 055
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
For 3mm sensing
In case noise generating equipment (switching regulator, inverter motor,
Front sensing
etc.) is used in the vicinity of this product, connect the frame ground
type sensor head
(F.G.) terminal of the equipment to an actual ground.
GP-A14F(I)
0 to 3mm
Do not run the wires together with high-voltage lines or power lines or put
Iron sheet
them in the same raceway. This can cause malfunction due to induction.
15 15 t1mm
Do not use during the initial transient time (0.5 sec.) after the power
supply is switched on.
The length of the sensor head cable cannot be changed.
Make sure that stress by forcible bend or pulling is not applied directly to
the sensor cable joint.
The alarm output is not incorporated with a short-circuit protection
circuit. Do not connect it directly to a power supply or a capacitive load.
Do not use the sensor at places having intense vibrations, as this can
cause malfunction.
Take care that the product does not come in direct contact with water, oil,
grease, organic solvents, such as, thinner etc., strong acid or alkaline.
Make sure that the sensing end is not covered with metal dust, scrap or
spatter. It will result in malfunction.
For stable sensing, carry out the adjustments 30 min., or more, after the
power supply is switched on.
3
MOUNTING
Make sure that the sensor head and the amplifier which have the same
production serial number (7 digit) are used in combination.
The length of the sensor head cable cannot be changed.
Mounting sensor head
The tightening torque should be under the values given below.
0.9 m/
Mounting with set screw [GP-A5S(I), GP-A8S(I) only]
1.5 m/
for
GP-A14FI
Make sure to use an M3, or smaller, set screw having a cup-point.
1.2 m/
Set screw (M3 or less)
(Cup-point)
A
Model No.
GP-A5S(I)
Enclosure:
GP-A8S(I)
Stainless steel
(SUS303)
Note: Do not apply excess torque.
Sensing part:
Mounting with nut [GP-A10M(I), GP-A12ML(I) only]
ABS
Mount such that the nuts do not protrude from the threaded portion.
<Threaded type>
GP-A10M(I)
GP-A12ML(I)
50g approx.
Attached toothed
Attached toothed
lock washer
lock washer
B
B
2 pcs. each of
Model No.
M3 countersunk
head
screws,
GP-A10M(I)
spring washers,
Mounting plate
Mounting plate
GP-A12ML(I)
plain
washers
and M3 nuts
Adjusting screw-
Mounting GP-A14F(I)
driver: 1 pc.
M3 counter sunk
head screw
2-M3 tapped holes
or thru-holes
8mm
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Distance from surrounding metal
As metal around the sensor may affect the sensing performance, pay
attention to the following points.
<Embedding of the sensor in metal>
Since the analog output may change if the sensor is completely embed-
ded in metal, keep the minimum distance specified in the table below.
Non-threaded type sensor head, threaded type sensor head
<Amplifier>
C
D
Metal
Front sensing type sensor head
GP-A14F(I) can be used by being completely
embedded in metal. However, the surrounding metal
should not protrude beyond the sensing face.
Metal
Mutual interference
If several sensor heads are mounted together, since the specifications
may not be met, keep the minimum separation distance given below.
Non-threaded type sensor head, threaded type sensor head
<Face to face mounting>
E
<Parallel mounting>
F
Front sensing type sensor head
<Face to face mounting>
<Parallel mounting>
Sensing face
G
Dependence of output characteristics on material (typical)
Take care that, depending upon the material of the sensing object, the
output differs as shown in the figures below.
GP-A5S(I)
8
Stainless steel
Stainless steel
6
(SUS304)
Aluminum
5
Brass
4
2
0
0.2
0.4
0.6
0.8
Setting distance (mm)
Set screw posi-
Tightening
GP-A12ML(I)
tion A (mm)
torque
0.44N m
8
5 or more
0.58N m
Stainless steel
(SUS304)
Brass
6
5
Iron
Aluminum
4
Stainless steel
(SUS410)
2
Tightening
B part (mm)
0
1
2
3
4
torque
Setting distance (mm)
7 or more
9.8N m
Mounting amplifier
14 or more
20N m
Mounting on DIN rail
With the stopper pressed in the direction of the
arrow (it locks), fit the front portion of the
amplifier mounting section on the 35mm width
DIN rail.
Lightly press the grooved section of the
M3 nut
stopper downwards when pressing the
Spring washer
stopper in.
Plain washer
Press and fit the rear portion of the amplifier
*
mounting section on the 35mm width DIN rail.
To remove, insert a flathead screwdriver into
the stopper and pull out.
Mounting with screws
Use two commercially available M4 (length
10mm or more) pan head screws.
The tightening torque should be 1.2N m or less.
Please arrange the pan head screws and
nuts separately. The mounting holes for the
screws can be accessed by removing the
terminal cover. To remove the terminal cover,
Model No.
C (mm)
D (mm)
insert a flathead screwdriver into the groove
GP-A5S(I)
4
of the terminal cover and lift up.
GP-A8S(I)
18
GP-A10M(I)
7
GP-A12ML(I)
50
14
Notes: 1)
2)
4
CONNECTION
Connection of sensor head and amplifier
Hold the sensor head's connector by the outer ring and insert it into the
connector provided on the amplifier for sensor head connection. Insert
till you hear a click sound.
Model No.
Condition
E (mm) F (mm)
Between 'I' type and non-'I' type
18
11
GP-A5S(I)
Between two 'I' types
50
36
or two non-'I' types
Between 'I' type and non-'I' type
22
11
GP-A8S(I)
Between two 'I' types
GP-A10M(I)
60
38
or two non-'I' types
Between 'I' type and non-'I' type
24
14
GP-A12ML(I)
Between two 'I' types
210
130
or two non-'I' types
Model No.
Condition
G (mm) H (mm)
Between 'I' type and non-'I' type
14
0
* To remove the sensor head, hold its connector by the outer ring and pull
GP-A14F(I)
Between two 'I' types
68
30
it straight out.
or two non-'I' types
Do not pull by holding the cable, as this can result in cable
Notes: 1)
'I' type is different frequency type.
H
disconnection.
2)
If the required resolution is lower than the specification
(0.04% F.S.), it is possible to bring the sensor heads
I/O circuit diagram
nearer than the separation distance given in the table
above. For further details, please contact our office.
GP-A8S(I), GP-A10M(I)
8
Stainless steel
(SUS304) Stainless steel
(SUS410)
6
(SUS410)
Brass
20
5
20
Aluminum
4
Iron
Iron
2
Sensor head
Note: In case of using the analog voltage output, connect a device having a high input impedance.
4
4
Also, take care that the output voltage is reduced due to the resistance of the wiring cable.
1
0
0.5
1
1.5
2
Setting distance (mm)
Symbols ... D
GP-A14F(I)
8
*1
Stainless steel
Stainless steel
(SUS410)
(SUS304)
Non-voltage contact or NPN open-collector transistor
6
Aluminum
20
5
20
Brass
Iron
4
Low (0 to 1V) (duration 30ms or more): External zero-adjustment setting
2
High (5 to 30V, or open): External zero-adjustment ineffective
Dimensions of suitable crimp terminal
4
4
5
0
1
2
3
4
Setting distance (mm)
3.2
or more
6
or less
Stopper
Note: Please use crimp terminals which have insulation sleeves.
35mm width DIN rail
Recommended crimp terminal: Type 1.25 - 3.0
Flathead
screwdriver
Stopper
M4 (length 10mm or more)
pan head screw
(Please arrange separately.)
Nut
(Please arrange separately.)
If two, or more, amplifiers are mounted together, make sure to leave a gap of at least 10mm
between them.
If the amplifier is installed in a control box, etc., ensure proper ventilation.
Amplifier
Connector for
Insert till the connector
sensor head
outer ring makes contact.
Connector
outer ring
Insert
Terminal No.
Amplifier
47
47
Analog voltage output
(0 to 5V) (Note)
0V (Analog output)
Analog output
100
Analog current output
(4 to 20mA)
Alarm output
Tr
100mA max.
Z
D
External
*1
zero-adjustment
D
1
input
D
2
+V
+
24V DC 10%
0V
-
Internal circuit
Uses' circuit
: Input protection diode
1
D
2
: Reverse supply polarity protection diode
Z
D
: Surge absorption zener diode
T
: NPN output transistor
r
Terminal No.
or
(Unit: mm)
Round type
Y-shaped type
3.2
10
10
or more
or less
or less
6
6
6
or less
or less
or less
19 or less
19 or less
(When crimped)
(When crimped)

Advertisement

loading

Summary of Contents for Panasonic GP-A5S

  • Page 1 Span adjustment (by 14-turn adjuster) The tightening torque should be under the values given below. 24V DC 10% 0.6 m/ 1.5 m/ 0.9 m/ Mounting with set screw [GP-A5S(I), GP-A8S(I) only] Temperature Sensor head 0.5 m/ 1 m/ for GP-A8SI and 2.5 m/...
  • Page 2 However, kindly note that the EEPROM has a life span and its Touch guaranteed life is 100,000 write operation cycles. Set the sensor head at the maximum distance [GP-A5S(I): 1mm, Notes: 1) The set values are not stored in the EEPROM if the power supply is switched off when the GP-A8S(I) and GP-A10M(I): 2mm, GP-A12ML(I): 5mm, GP-A14F(I): switch is on the 'FREE' side.

This manual is also suitable for:

Gp-a10mGp-a14fGp-a12mlGp-a8sGp-a5siGp-a8si ... Show all