THREE
OPERATION INSTRUCTION
1) Button and icon instructions
2) Instructions of buttons:
a. ON/OFF: Each press ON/OFF, unit runs in a circulate "on-off-on"
b. Humidity Down: When unit runs on dehumidify mode, press
Humidity Down button each time, humidity falls 1%, press for 2
seconds, humidity falls by 5% per second.
c. Humidity Up: When unit runs on dehumidify mode,
press Humidity Up button each time, humidity raises 1%,
press for 2 seconds, humidity raised by 5% per second.
3) Instruction of function mode:
Unit makes a "BEEP" sound when powered on. Then when switch
button is in humidity mode, the indicator light of the Dehumidifier
will light up.
The default setting for humidity is 60%, the machine's dehumidifying
range is 30%-90%. Use the Humidity Up and Down buttons to adjust
the humidity setting. If you keep pressing the Humidity Down button
when the humidity setting is at 30%, the unit will go into continuous
dehumidify mode which will show as "CO" (Continuous Operation)
on the the LCD display. The humidity % will flash when setting the
humidity, then display current humidity after 5 seconds.
: