Permanently connected installation instructions
Electrical installation should be performed by a qualified licensed
electrician.
1.
Remove cabinet service panel. The panel is secured with pan
head Phillips screws.
2.
Remove system controller cover.
3.
If spa was manufactured with a cord.
a. Disconnect cord wires from terminal TB1 and ground wire from
ground bar.
b. Loosen cord strain relief.
c. Remove cord.
d. Remove strain relief.
4.
Drill hole for conduit through bottom or side of spa.
WARNING: DO NOT TURN ON POWER UNTIL TUB IS FILLED COMPLETELY WITH WATER!
Your Hot Tub is designed to provide optimum performance when connected to the maximum electrical service. The listing below will show the various options and
performance levels available on your hot tub.
A new GFCI must be used for your Hot Tub installation. Do not use an existing breaker (GFCI), as its condition is unknown.
On all systems, your Hot Tub must be connected to a dedicated circuit breaker that is not shared with any other equipment.
Amp Volts
15A 120V Only
# of wires
Includes Cord
110 Sport™
110 Warrior XL™
110 D'Amour™
110 Stella™
110 Retreat™
110 Encore™
110 Jubilee™
Amp Volts
# of wires
1.
Clean tub of all debris.
2.
Use a garden hose to fill your hot tub through the empty filter canister (to
avoid air pockets during filling) to the appropriate level of a minimum 2
inches (5.08cm) over the filter skimmer.
3.
DO NOT USE WATER THROUGH A WATER SOFTENER.
4.
Locate the shut-off T-valves. Make sure they are in the up or open
position.
5.
Check heater and pump unions. Occasionally during
POWER INSTALLATION INSTRUCTIONS, continued

POWER REQUIREMENTS

DO NOT USE EXTENSION CORDS OF ANY KIND.
15A 120V / 40A 240V
3/4
Impulse™
Impulse DP™
Bella MS™
230V 16A
Omni™
Crown XL™
Impulse™
Bella MS™
Impulse DP™
D'Amour MS™
Crown II™
Stella MS™
Warrior XL™
Retreat MS™
Crown™
Escape MS™
Escape R MS™
Jubilee MS™

START-UP INSTRUCTIONS

5.
Secure conduit at system controller box.
6.
Connect hot and neutral wires to corresponding terminals TB1.
Connect ground wire to grounding bar on the outside of box by
running it though hole marked for ground wire.
7.
Voltage selection for North American 60 Hz systems.
a. 120V installation. Attach jumper to J11 and J32. A jumper wire is
supplied in a bag attached to the back or side of controller. Switch
DIP switch A10 to on (up).
b. 240V installation. Remove J11 to J32 jumper if installed. Switch DIP
switch A10 to off (down).
8.
Attach system controller cover.
9.
Attach cabinet service panel.
20A 120V / 40A 240V
3/4
Crown II™
Crown™
Warrior XL™
D'Amour MS™
Stella MS™
Retreat MS™
Escape MS™
Escape R MS™
Encore MS™
Jubilee MS™
3
Encore MS™
D'Amour SE™
Stella SE™
Retreat SE™
Escape SE™
Escape R SE™
Encore SE™
Jubilee SE™
shipping these become loosened. A simple tightening of these (if
necessary) will do, being careful not to over tighten.
6.
Once water has reached correct level, turn power on to the hot tub.
7.
To activate jets and to purge air from the pump, press/push jet button
located on the top side control. A second press/push will put the pump on
high speed. Repeat this process until water flows from the jets. When the
jets are working, set the pump to low speed.
8.
Some start-up chemicals will be needed; please see your
40A 240V Only
50A 240V Only
4
Crown XL™
Escape LS™
D'Amour SE™
Escape R LS™
Stella SE™
Encore LS™
Retreat SE™
Rendezvous LS™
Escape SE™
Jubilee LS™
Escape R SE™
Encore SE™
Jubilee SE™
230V 32A
3
Escape LS™
Escape R LS™
Encore LS™
Rendezvous LS™
Jubilee LS™
4
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents