Phyn Plus installation guidelines
Maximum working pressure is 100psi at 73.4 F (23 C).
Use caution when applying heat near Phyn Plus, as damage to the
device or gaskets may occur. Make any heat related connections prior
to installing the device.
To avoid risk of fi re and shock: use only the provided cable and
power adapter.
When connecting Phyn Plus, verify that the coupling nuts are properly
aligned to avoid cross-threading or damage to the device. An e ective
method for starting the coupling nut is:
1
Position the nut squarely against the threaded end of
the device.
2
Turn the nut counterclockwise (in reverse) while holding the
nut against the device threads. When the fi rst threads on the
nut and the device coincide, you will hear a slight click and
feel the nut move into the starting position.
3
Finger tighten the nut until it is snug.
4
With an open-end wrench, apply a partial turn. Do not over
tighten. A one-quarter turn is usually su cient.
The gap between fi ttings should be 11-5/16 inches to accommodate the
device and two gaskets.
Use cable tie mounts and zip ties (included in box) to ensure that no
cables are hanging loose or creating a hazard.