Lutron Electronics DL-9602SD Operation Manual
Lutron Electronics DL-9602SD Operation Manual

Lutron Electronics DL-9602SD Operation Manual

Sd card, real time datalogger

Advertisement

Quick Links

SD card, real time
DATALOGGER
Model : DL-9602SD
OPERATION MANUAL
Your purchase of this
SD CARD REAL TIME
DATALOGGER marks a
step forward for you
into
the
precision measurement.
A l t h o u g h
DATALOGGER
complex
and
instrument, its durable
structure
will
many years of use if
p r o p e r
o p e r a t i n g
t e c h n i q u e s
developed. Please read
t h e
f o l l o w i n g
instructions
and always keep this
manual
within
reach.
field
of
t h i s
is
a
delicate
allow
a r e
carefully
easy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL-9602SD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lutron Electronics DL-9602SD

  • Page 1 SD card, real time DATALOGGER Model : DL-9602SD Your purchase of this SD CARD REAL TIME DATALOGGER marks a step forward for you into field precision measurement. A l t h o u g h t h i s DATALOGGER...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES................1 2. SPECIFICATIONS..............2 3. FRONT PANEL DESCRIPTION..........4 3-1 Display................4 3-2 Power Button..............4 3-3 Backlight ON/OFF Button ( Esc Button )......4 3-4 LOGGER Button ( ENTER Button )........4 3-5 Channel Button ( Button )..........
  • Page 3 1. FEATURES * Real time SD memory card Datalogger, it can cooperate with most LUTRON instruments if it build in the computer interface. * Built-in Clock and Calendar, real time data recorder , sampling time set from 1 second to 8 hours 59 minutes 59 seconds.
  • Page 4: Specifications

    2. SPECIFICATIONS Application * Real time SD memory card Datalogger can cooperate with all LUTRON instruments if it build in the computer interface. * Innovation and easy operation, computer no need to setup extra software, after execute datalogger, just plug in the SD card into the computer, it can down load the all the measured value and unit along with the time information ( year/month/date/...
  • Page 5 Sampling Time Auto 2 seconds to 8 hours 59 min. Setting range 59 seconds. @ Sampling time can set to 1 second, but memory data may loss Manual Push the data logger button once will save data one time. @ Set the sampling time to 0 second.
  • Page 6: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Power Button 3-3 Backlight ON/OFF Button ( Esc Button ) 3-4 LOGGER Button ( ENTER Button ) 3-5 Channel Button ( Button ) ▲ 3-6 Start/Pause Button 3-7 Time Button ( Button ) ▼...
  • Page 7: Measuring Procedure

    Socket " ( 3-10, Fig. 1 ) of DL-9602SD. b. For connecting the Isolate RS232 instruments should plug the UPCB-03 to the " ISOLATE input Socket " ( 3-11, Fig. 1 ) of DL-9602SD. c. Should power on the " Data Source Meters " before input the data.
  • Page 8: A Insert The Sd Card

    4-2A Insert the SD card Prepare a " SD memory card " ( 1 GB to 16 GB, optional ), insert the SD card into the " SD card socket " ( 3-9, Fig. 1). The front panel of the SD card should face against the down case.
  • Page 9: B. Pause The Datalogger

    b. Pause the datalogger During execute the Datalogger function ( the lower LCD show the text " DATALOGGER " with flashing ), if press the " Start/Pause Button " ( 3-6, Fig. 1 ) will pause the Datalogger function ( stop to save the measuring data into the memory circuit temporally ).
  • Page 10: C. Finish The Datalogger

    c. Finish the datalogger During the period of executing the Datalogger function, if press the LOGGER Button ( 3-4, Fig. 1 ) once will finish the Datalogger function. Then the text of " DATALOGGER " will be disappeared. Following the lower LCD will show the text "...
  • Page 11: E. Data Structure

    e. Data structure 1) When the first time, the SD card is used into the meter, the SD card will generate a route : DLGO1 2) If the first time to execute the Datalogger, under the route DLG01\, will generate a new file name DLG01001.XLS.
  • Page 12: To Check The Time Information

    4-4 To check the time information Under the normal measurement condition ( it do not execute the Datalogger function ). 1) Press " Time Button " ( 3-7, Fig. 1 ) once , the lower LCD display will present the time information of Hour/Minute/Second ( h.m.s ) in the lower Display.
  • Page 13: Lcd Backlight On/Off

    Suppose you already set the meter to accept 4 channels input, if intend to show the channel 3, channel 4 value, then during execute the Datalogger function ( the lower LCD show text " Datalogger " with flashing ), then press "...
  • Page 14 3) Power ON the computer and run the " EXCEL software ". Down load the saving data file ( for example the file name : DLG01001.XLS, DLG01002.XLS ) from the SD card to the computer. The saving data will present into the EXCEL software screen ( for example as following EXCEL data screens ) , then user can use those EXCEL data to make the further Data or Graphic analysis...
  • Page 15: Advanced Setting

    6. ADVANCED SETTING It do not execute the Datalogger function. Press the " SET Button " ( 3-8, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode. then press the " Set Button " once a while in sequence to select the eight main function, the lower display will show : Sd F..
  • Page 16 2) If select the upper to " yES ", press the " Enter Button " ( 3-4, Fig. 1 ) once again, the Display will show text " yES Enter " to confirm again, if make sure to do the SD memory card format, then press "...
  • Page 17: Set Clock Time ( Year/Month/Date, Hour/Minute/ Second )

    6-3 Set clock time ( Year/Month/Date, Hour/Minute/ Second ) When the upper display show " dAtE " 1) Use the " Button " ( 3-5, Fig. 1 ) or " Button " ▲ ▼ ( 3-7, Fig. 1 ) to adjust the value ( Setting start from Year value ).
  • Page 18: Auto Power Off Management

    Remark : The adjusted value will be flashed. 2) After set all the sampling time value ( Hour, Minute, Second ), press the " SET Button " ( 3-8, Fig. 1 ) once will save the sampling value with default then the screen will jump to "...
  • Page 19: Decimal Point Of Sd Card Setting

    2) After select the upper text to " yES " or " no ", press the " Enter Button " ( 3-4, Fig. 1 ) will save the setting function with default. 6-7 Set beeper sound ON/OFF When the lower display show " bEEP " 1) Use the "...
  • Page 20: Power Supply From Dc Adapter

    2) After select the upper text to " bASIC " or " Euro ", press the " Enter Button " ( 3-4, Fig. 1 ) will save the setting function with default. 7. POWER SUPPLY from DC ADAPTER The meter also can supply the power supply from the DC 9V Power Adapter ( optional ).
  • Page 21: System Reset

    9. SYSTEM RESET If the meter happen the troubles such as : CPU system is hold ( for example, the key button can not be operated... ). Then make the system RESET will fix the problem. The system RESET procedures will be either following method : During the power on, use a pin to press the "...

Table of Contents