SET OUT-OF-RANGE DISTANCES – NEAR, MIDDLE AND FAR
GUARDIAN ANGEL USER MANUAL
The Base unit can configure more or less tolerable out-of-range distance
limits (Near, Middle, Far) for each individual tag. You can also deactivate
1

INTRODUCTION

the tracking function (DISALARM) to a certain Tag Unit.
Guardian Angel is a digital wireless personal tracking device that keeps
1. Hold down the the "Configuration"
children, pets, keys and other valuables close by your side. The Guardian
button on the side of the Base unit. One
Angel comes with a Base tracking unit and (up to) four Tag units that are
of the "Connection Status" lights will
each attached to tracked items (e.g. keys). This product can alert you when
illuminate red indicating one of the Tag
a tracked item goes out-of-range and can search for the item within a
units. If it is NOT the Tag unit you want
1,600 feet radius. A child or an elderly person can also press a panic
to configure, then let go of the
button on the Tag unit to call/alert the Base unit. Please search "Guardian
"Configuration" button and press down on it
Angel 807G" from YouTube Demo Video.
again – the "Connection Status" light will

KEY FEATURES

illuminate for the next Tag unit in
- Works indoors and outdoors.
sequence. Do this until you reach the
- Lightweight and easy-to-use.
desired Tag unit.
- No assembly or installation (only batteries).
2. While continuing to hold down the
- Uses safe 2.4 GHz RF technology.
"Configuration" Button on the Base unit,
- Base unit tracks up to four tags.
press the "Search/Set" button
- Out-of-range distances for a Tag unit can be configured at 32 feet, 64
underneath the illuminated "Connection
feet, or 160 feet (with some variability due to terrain and other factors).
Status" light. Notice that the illuminated
- 1,600 feet search radius (distance will vary depending on terrain and
"Strength indicator" light will change from
other factors.).
"Near", "Middle", "Far" and "Disalarm" (as
- Base unit has a direction indicator to facilitate tag search.
marked on the Base Unit) each time you
- Alerts are issued with a 95 dB alarm and vibration.
press the "Search/Set" button. When you
arrive at the desired setting, let go of the
- Tag units can issue a Panic/Stress alert to the Base unit.
"Configuraton" button and the changes

SPECIFICATIONS

will take effect for that Tag unit.
Model Name
Note: You can configure the out-of-range distance for a Tag unit only if
Search Range
that Tag unit and the Base unit are currently linked.
Function

DISALARMING A TAG UNIT

Alarm Distance
If there are one or more Tags that are not in use, you can deactivate or
Base Unit / Tag Unit Specs
"Disalarm" them so that the Base will not issue any alerts for them. In
Battery Type
the instructions above for setting out-of-range distances, there is a fourth
Battery Life Time on Standby
option marked "Disalarm" on the Base Unit. You can set a Tag to this
Beep Sound
(at 10 cm / 3.9 inches)
option if want the Base unit to disregard that Tag unit.
Vibration
Dimensions (L/W/H)
2
SEARCHING FOR A MISPLACED TAGGED ITEM (continued)

GETTING STARTED - Out-of-range Alerts

5. Move in the direction in-line with where the
This section shows how to quickly setup and trigger an alert condition
front of the Base Unit points when the
when the Base unit is separated from the Tag units.
Green light is lit. As you move closer and
closer to the Tag unit, the Base unit chirp
1. Insert the batteries into the Base unit and the four Tag units.
intervals will increase in frequency and the
- Slide out (remove) the battery covers on the Base and Tag Units.
"Signal Strength" lights will display
- Insert batteries (included) according to the polarity markings (+/-)
additional red lights. If the Base unit chirp
in the battery compartments.
intervals slow and the red "Signal
- Replace the battery compartment covers on both units.
Strength" lights become fewer, you may be
moving in the wrong direction and losing
Base unit
signal strength – at this point you may
Install Battery
need to stop and recalibrate again.
6. As you become very close to the Tag
unit, the "Signal Strength" lights will
all be illuminated – however, if you are
right on top of or very close to the Tag unit,
the "Direction Indicator" may give
inaccurate readings. At this point you
Replace Cover
should mute the Base unit (Mute button on
the side of the Base unit) and follow the
2. Switch "On" the power button on the Base and Tag units. Disregard any
Tag unit's beep in order to pin-point its
alerts while the Base unit and 4 Tag units are linking up. After the Base
location.
and all Tags link up, they will display blinking lights at regular intervals.
7. Once the Tag unit is found, press the
3. Place the Tags in a stationary location, and with the Base unit in hand,
"Search/Set" button on the Base unit again
walk away from the Tags. At about 64 feet, the Base unit will begin
to cease the search function.
to vibrate and beep. The Tag units will also beep.
4. Return the Base unit to the vicinity of the
Tag units and all beeping will cease.
In quiet areas (e.g. libraries), it is possible to conduct a silent search,
where both the Base and Tag units are muted. To do this simply, turn on
the "Mute" button on the Base unit before pressing the "Search/Set"
button and then use the Direction Indicator and Signal Strength lights.
32 Feet
The "Mute" button on the side of the Base unit can be switched on at any
time to silence the Base unit to avoid distraction in quiet areas (e.g.
libraries).
807G
0~500m/1600 ft
Alarm & Search 1 to 4 Tags
Near:32'±16' Middle:64'±32'
Far:160'±64'
Base (M07A)
Tag (S08A)
AAA x 2
CR2032
60 days (8 hrs)
30 days (8 hrs)
95 dB
95 dB
None
Vibration Motor
3.75" x 2.56" x 0.56"
2.38" x 1.5" x 0.42"
Page 1
Page 5
Tag unit
Press and
release
Install
Battery
Remove Cover
Remove Cover
Replace Cover
Press and
release
Page 3
Page 7
3

PACKAGE CONTENTS

SEARCHING FOR A MISPLACED TAGGED ITEM
Model Name
807G
807G2
When a tagged item is misplaced, you can use the Base unit to search for
1 pc
Base Unit
it, if it is within a 1,600 feet (500m) radius. Test this for Tag unit #1 in an
1 pc
2 pcs
Tag Unit
open area (e.g. large room, or in your yard).
AAAx2
AAAx2
Batteries
CR2032x1
CR2032x2
1. On the Base unit, press the
Strap
1
"Search/Set" Button once for Tag unit
Clip / Hook
1/0
#1 – one or more of the 5 "Signal
User manual
1
Strength" lights will illuminate on the

OVERVIEW

Base unit, indicating the relative
Base Unit
distance from Base to Tag. The Base
unit will also begin to chirp at regular
Front
1
intervals.
5
The Tag unit will also begin to beep,
6
allowing you to follow the audible to
7
pin-point its location, if it is near by.
2
8
3
2. You must first calibrate the Base to
4
the current environment. Hold the Base
unit in front of you, at chest level and
scan the area slowly in a circular
Tag Unit
direction, from right to left for 360° and
Front
1
again from left to right (one 360° turn in
2
3-4 seconds).
Note: If the "Direction Indicator"
illuminates green on the Base unit
3
during this calibration process, it does not
4
yet indicate a Tag unit's direction.
4. Next, slowly scan a third time from
5
right to left. The "Direction Indicator"

SUGGESTED LOCATION TO PLACE BASE / TAG units

on the Base Unit will illuminate (green)
Base Unit
when it establishes the direction of the
tagged item location.
Note: You don't have to scan a full 360°; you
can use a narrower search angle (e.g.
180°), but you must still calibrate the Base
unit from left to right, right to left and then
scan to search.
4
a) When the Base loses the signal to a Tag unit (i.e. out-of-range), the
The Tag units have an additional function of allowing a child or elderly
Base unit beeps and vibrates for 10 seconds; the Tag unit beeps for 15
dependent to call the Base unit for help. To activate the Panic alert, press
seconds. The Base unit will not alert continuously while the Tag is
and hold down the panic button on the Tag unit; the Base unit will beep and
out-of-range, but will continue to issue a beep every 30 seconds and try
vibrate, and a solid, bright red blinking "Connect Status" light on the Base
to relink to the Tag at regular intervals.
unit will clearly indicate which Tag has activated the panic alert.
b) When the Tag Units and Base Unit are within close proximity, lights on
all units blink dimly at regular intervals, indicating active link statuses
5
BATTERY INFO - MAINTENANCE & LOW BATTERY CHARGE
between Base and Tag units – this is referred to as "Standby Mode".
c) You can Mute the Base unit alarm at anytime by pressing the "Mute"
When the Base unit or Tag unit is not in use, it is advised that you turn them
button on the right side.
off to conserve battery power.
When the Base unit or Tag unit battery charge runs low, both units will
issue a low level beep every 2 minutes, alerting you to change the
batteries. If you run your units on low batteries, operations may become
In the "Getting Started" section, you learned how to set off the out-of-range
unpredictable or results may be innacurate.
alerts for all the Tag units. You now need to be prepared to manage all 4
tagged items from the Base unit at the same time – with a little practice,
6
operations can easily be mastered.
There are 4 "Connect Status"
The Base and each of the Tag units are "Paired" before shipment - that is,
lights on the Base unit. The
each Base-to-Tag combination must have it's own unique communication
blue Tag unit is associated with
handshake, so that the Base does not get confused between the Tag units.
the far left status light (#1), the
The procedures below are used to re-establish the "Pairing" in case a Tag
red with the second, the green
unit is replaced or a Tag unit cannot communicate with the Base unit. For
with the third and the yellow
this example we "Pair" the Base unit and Tag #2 (red) - follow the
with the fourth light. If a single
instructions below
Tag unit goes out-of-range, the
1. Make sure the Base unit and ALL the Tag units are turned off.
respective Connect Status light
2. To enter "Registration" mode, hold down the "Configuration" button (on
will blink a bright red color.
the Base unit) and the "Search" button for Tag #2 (also on the Base unit)
On the Base unit, below each
and then, at the same time, turn on the Base unit - as soon as the red
"Connect Status" light, is an
light above the "Search" button (for Tag #2) flashes exactly twice
associated "Search/Set" button
release the buttons (if you've already reached the 3rd flash, you have to
dedicated to one of the tag
start again).
units. In subsequent sections,
If you've entered the "Registration" mode successfully, the light above
you will use this button to
"Search" button and the light below the "Dis-alarm" light on the Base
manage individual Tag units
unit will flash together.
from the Base unit.
3. Finally, bring Tag #2 to within 10 cm (4 inches) of the Base Unit and turn
it on. TheTag unit will beep twice, indicating a successful "Pairing".
807G3
807G4
1 pc
1 pc
1 pc
3 pcs
4 pcs
AAAx2
AAAx2
CR2032x3
CR2032x4
2
3
3
1/1
1/1
1/1
1
1
1
Back
Press and
Strap attachment
1
release
Connect status LED
2
9
Power switch
3
Search/Set button
4
Direction indicator
5
10
Configuration button
6
Signal strength lights
7
Press and
release
Mute button
8
Speaker
9
11
Clip
10
Battery cover
11
Back
Ring attachment
1
Speaker
2
360
360
Connect status LED
3
Panic button
4
Power switch
5
Battery cover
6
6
Tag Unit
Press and
release
Page 6
Page 2
Blue
Red
Green
Yellow
Page 4
Page 8
Connect Status
Lights
Search/Set
Buttons

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Guardian Angel and is the answer not in the manual?

Questions and answers

Summary of Contents for Ardi Technology Guardian Angel

  • Page 1 (DISALARM) to a certain Tag Unit. open area (e.g. large room, or in your yard). AAAx2 AAAx2 AAAx2 AAAx2 Guardian Angel is a digital wireless personal tracking device that keeps Batteries 1. Hold down the the “Configuration” CR2032x1 CR2032x2 CR2032x3 CR2032x4 1.
  • Page 2 (DISALARM) to a certain Tag Unit. open area (e.g. large room, or in your yard). AAAx2 AAAx2 AAAx2 AAAx2 Guardian Angel is a digital wireless personal tracking device that keeps Batteries 1. Hold down the the “Configuration” CR2032x1 CR2032x2 CR2032x3 CR2032x4 1.

Table of Contents