INSTALLATION GUIDE – WALL-MOUNTED DESIGN CONVECTOR GS
1. UNIT DESCRIPTION
Design wall-mounted GS convector with a face cover
panel. The glass panel can be removed from the con-
vector body. The stainless steel body of the convector
is equipped with adjusting screws in the lower part of
the back side which are used to compensate for the
deflection from the wall.
2. CONTENTS OF THE BOX
1. CONVECTOR BODY – supporting member of the
convector parts (heat exchanger, valves and front
panel).
2. COVER PANEL – a design piece within the convec-
tor – GS glass.
3. AiR VENT VALVE – used for venting (bleeding) the
convector.
4. ANGLE VALVE DUO – a valve used for flow regula-
tion.
5. THERMOSTATiC VALVE – used for manual regula-
tion.
6. fiXiNG HOLES – for attaching the convector to the
wall.
3. TECHNICAL PARAMETERS
GS design convectors are to be mounted on the wall or a partition wall with adequate load-bearing capacity with vertical positioning using the adjusting screws located in the
lower part of the back side of the convector body. The accessories include fixing screws for attachment. Standard dimensions of the GS convector: Height 280 mm, 360 mm
and 480 mm; length 1 000 mm and 1 250 mm.
4. INSTALLATION AND FIXING OF THE UNIT
Read the installation instructions before the installa-
tion. Attach the unit to the wall using the screws and
screw anchors from the accessories supplied. Hang
the unit using the holes cut out in the back side of the
stainless steel body of the convector.
Benefits of the GS design convector:
Possibility to choose your own design from the
MiNiB catalogue
High output
Silent operation
Low hot water consumption
Minimum requirements for operation and mainte-
nance
A
GS 280
772
GS 360
772
GS 480
772
Use: dry environment, according to the specifica-
tion.
Maximum operating pressure: 1 MPa.
Maximum operating temperature: 90 °C.
Operating medium: water. Water may not be mixed
with other substances, such as antifree¬ze fluids!
Environment: interiors with temperatures ranging
between +5 °C and +40 °C.
GS CONVECTOR – REAR VIEW
fiG. 1:
Dimensions for drilling, rear view.
fiG. 2:
Table 1: Dimensions for drilling.
1 000
B
198
288
385
1 250
A
B
1 022
198
1 022
288
1 022
385

Advertisement

loading
Need help?

Need help?

Do you have a question about the GS 360 and is the answer not in the manual?

Questions and answers

Summary of Contents for Minib GS 360

  • Page 1 Dimensions for drilling, rear view. fiG. 2: Table 1: Dimensions for drilling. 1 000 1 250 GS 280 1 022 GS 360 1 022 GS 480 1 022...
  • Page 2 PRODUCTION part of the unit, and finally tighten. Connect the valves to the Manufacturing plant of MiNiB, a. s heating line. fit the thermostatic valve. Býkev u Mělníka 84, 276 01 Býkev Czech Republic www.miniB.cz...

This manual is also suitable for:

Gs 480Gs 280