Download Print this page
Avanti S-Series Installation And User Manual

Avanti S-Series Installation And User Manual

Advertisement

Quick Links

C
Transmi er Coding
1
1) Bulk Coding same as Factory Se ng. (
)
B
1.1
(
)
Bulk Coding from Control Panel
see Pic 1.1
1.) On Display Press Bu on . Display shows
,
Learn
Courtesy LED Light begins to flash.
2. Press new Transmi er twice un l LED fast flashes.
)
Learning Complete.
1.2 Bulk Coding from coded Transmi er (see Pic 1.2)
1. On already coded Transmi er Long press Light
)
Func on (Bu on 3 on pre - coded Transmi er) for 5
sec. Display shows
, Courtesy LED Light begins to
flash.
2. Press new Transmi er twice un l LED fast flashes.
)
Learning Complete.
Pic 1.1
Pic 1.2
Learn
press once
press twice
Long Press 5 sec
press twice
D
Func on Setup
1.) To Enter Func on Setup Menu: press
at the same me. 3.) Now choose value with
2.) Use
and
to scroll up and down through the func ons.
Press
to select the desired func on.
Func on Descrip on
Values
Disable Safety Beam
Safety Photo Beam
Enable Safety Beam in
CLOSE Direc on
Automa c Close
Safety Beam Func on
Func on
not enabled
05 sec /
Safety Beams
must
be enabled!
30 sec
8.2 kOhm Safety
Disable
Contact Strip
Safety Strip
Running Speed of
High Speed
Opener
Short Slow
Slow Stop Func on
Stop
Full Power Mode
Func on not available in this version
Courtesy Light
1 min
Illumina on me
Par al reverse /
A er Hi ng Obstruc on,
Door will: Par al Reverse
Full reverse
Signal Reverse /
At press TX in Close
Signal Stop
Direc on,Door will: Stop
Ven la on
If door is idling in
OFF
Ven la onPosi on,
Mode Time
shows in Display.
Ven la on
OFF
Re-Opening Height
Door Service Monitor
OFF
Car Park Mode
OFF
Opener Stops a er
Maximum Run Time
30 sec Run Time
A er reaching Close Posi on, Motor drives back 3mm
Back Jump
to release pressure from door
External Flash Light
OFF
Output
Outside Menu Func ons
Holiday Mode: Press Holiday Func on (Bu on 2 on Bulk-Coded TX) for 3 seconds. Places Opener in a dormant state AFTER closing.
Factory Reset: Switch off opener first. Ini ate Reset by pressing
Forced Relearn: Drive Door into ANY Posi on but CLOSE. Long Press
E
Safety Photo Beam
2W
4W
SB
Door in Door
There are two ways to learn a new transmi er:
)
1 Bulk Coding same as Factory Se ng. (
2 Assign certain Func ons to certain Transmi er Bu on.
)
2
2) Assign certain Func ons to certain Transmi er Bu on.
Every Button of a Transmitter can be programmed with a
different Function as Listed below:
Bulk Coding - (TX learns Func ons as shown in
Run Func on - Open/Stop/Close ( see
B
1
Ven la on / Holiday Mode Func on ( see
Light Func on
-
( see
B
3
)
Run Func on/Auto Close Override - ( see
OPEN Func on - Only OPENS Door
CLOSE Func on - only CLOSES Door
)
1. Short press
on Opener,
Learn
2. Use
)
and
to choose the desired func on (see List above ).
3 3
Delete all Transmi ers
Delete all Transmi ers
1. Short press
)
on Opener,
Learn
2. Long press 5 sec
)
un l light starts flashing, Finished.
Confirm
and
chosen value by pressing
.
4.) To Exit Func on Setup Menu at any me: press
Enable Safety Beam in CLOSE and OPEN
Direc on.
If Safety Beam is ac vated by passing car or person:
No Auto-Close
Door automa cally closes a er 5/15/30 sec.
15 sec /
If Safety Beam is NOT ac vated by passing car or person:
30 sec / 180 sec
30 sec / 180 sec
90 sec
Door automa cally closes a er 30/90/180 sec.
Enable Safety Strip
Tip Up Door
A er setup,
Low Speed
Speed
Follow Steps .
Long Slow
No Slow
A er setup,
Stop
Stop
Follow Steps .
A er setup,
Follow Steps .
If Courtesy Light is switched on by Hand Transmi er Light
3 min
2 min
Func on, it will not automa cally switch off.
A er Hi ng Obstruc on,
Door will: Fully Reverse
At press TX in Close Direc on,
Door will: Reverse
With ac vated Ven la on Mode: Short Press Ven la on
Mode Bu on on Transmi er (2nd Bu on on Bulk Coded
Transmi er), Door will close completely, and then re-
Height of
-
open between 2-18 cm for Ven la on Purposes. A er set
Ven la on Slit
15/30/45/60/75/90 min door will automa cally close.
If Door is out of Balance, Light will
flash during run to warn user
Accessories wired to COM/NO Connector (Key-Switch, Card Readers, etc.) will only
trigger OPEN Func on. Hand Transmi ers are NOT effected by this func on.
Opener Stops a er
60 sec Run Time
OFF
Steady Output
Blinking Output
Output same as
3s Delay
3s Delay
Courtesy Light
and power on un l Display shows
. Previouslycoded TX will not be deleted.
Learn
for 5 sec un l Display shows
. See
5
for further instruc ons.
Learn
OnIy"OPEN" Func on
2W
4W
SB
Chain Black
Red
Rail
Yellow
Yellow
Open Limit
B B
)
B
)
)
B
2
)
)
B
4
A A

Control Panel

. Confirm
.
will start.
5
will start.
5
will start.
5
B
Transmi er Func ons Ex Factory
1
Alternately Opens, Closes or Stops the Garage Door.
1
2
2
Short Press - Ini ates a Drive into Ven la on Mode
3
Posi on. (Only available if Ven la on Func on
4
enabled.)
Long Press (3 sec) - Ini ates Holiday Mode. Places Opener
into a dormant state a er reaching Close posi on. Refer to
D
is disabled.)
3
Light / Transmi er Coding
Short Press - Switches Courtesy Light ON and OFF.
Long Press (5 sec) -
is displayed.
4
Run / Auto Close Override
If Auto-Close disabled - Func ons same as Bu on
If Auto-Close enabled - Func ons same as Bu on
Auto-Close when opened from this bu on. Press for 3 sec to ac vate.
Open/Stop/CIose
If accessories connected
to COM/NO are required
to ONLY trigger the
OPEN direction,
Mode
needs to be set to
.
This does NOT effect any
Hand Transmitter
Functions.
LAMP
Ba ery Backup
S-Series Garage Door Opener
Installa on- and User Manual
Learn
In Standby: Decrease or Increase Force Offset Values (
Press
and
In Func on Setup Menu: Scroll Func ons and Values (
In Transmi er Setup Menu: Scroll Func ons (
Short Press: Enter Transmi er Setup Menu (See
Learn
Confirm
Long Press (5 sec): Forced Relearn (See
In any Setup Menu: Exit Menu.
In any Setup Menu: Exit Menu.
In Standby: Acts as Run Bu on (Open and Close Door)
In Setup Menus: Confirm Chosen Func on or Value
Confirm
Run Bu on: Open and Close Door. Con nuos Press
overrides Safety Beam in Close Direc on.
Run Func on
Ven la on / Holiday
for details. (Only available if Ven la on Func on
Enter Transmi er Setup Menu.
Refer to
for details.
C
.
1
, however Door will not
1
RS
SB
COM
24V NO
COM
ANT
GND
Coax Antenna
Transformer
EN
10-10102-X
Version: 3.0t
G
)
together: Enter Func on Setup Menu (
)
D
D
)
C
)
)
C
D
)
How to Change Ba eries
1 1
is
2
3
+
Panasonic
CR2016
3V
+
+
Panasonic
Panasonic
CR2016
CR2016
3V
3V
Warning Light 24V AC
Max. 2A
Warning Light 230V AC
- -
24V AC
N N
L L
Relay
230V AC
NC
8.2 kOhm Safety
Contact Strip

Advertisement

loading
Need help?

Need help?

Do you have a question about the S-Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Avanti S-Series

  • Page 1: Control Panel

    Display shows , Courtesy LED Light begins to OPEN Func on - Only OPENS Door flash. S-Series Garage Door Opener CLOSE Func on - only CLOSES Door 2. Press new Transmi er twice un l LED fast flashes. 1. Short press on Opener, Learning Complete.
  • Page 2 Assemble Rail, Mount Control Unit and Running Unit, Tension Chain Running Unit Control Unit Mount Brackets and Rail < 50mm Install Track NOT HIGHER than 50mm above highest arcing point of Door Panel! Posi on Close/Open Stopper Learning Travel & Force Engage Running Unit, Connet to Power Supply CLOSE the Door by hand, then slide the Stopper as shown in drawing Long Press Transmi er Bu on 1 for 3 seconds un l Light Fast Flashes.